                                                                                                                   MyChron 3 Plus/Gold BIKE - -Version 1.01 

2

Installation notes 

 

 

We recommend to choose a place where the instrument will not be in contact with oil or 
fuel, be sure that the gauge is not installed too close to heat sources and protect the 
instrument from vibrations; 

 

To correctly measure the gyroscope input (

MyChron 3 Gold

 only), we suggest You to 

install the external optional gyroscope. The gyroscope is resistant to shocks but can 
become critical to vibrations: for this reason it should be fixed to the chassis only with 
strips; 

 

We remind you that your 

MyChron 3 Plus/Gold

 is not equipped with internal batteries, 

and so it needs to be powered by an external 

9 – 15V

 power source (i.e. the BIKE’s 

battery). 

Do not exceed these limits.

 

 

When the gauge has been correctly installed, plug the input cable inside the MS female 
connector on the gauge’s back-side. 

 

When the input cable has been plugged, please connect the sensors in the input cable. 

 

How to connect MyChron 3 Plus/Gold BIKE to the PC 

 

To connect your 

MyChron 3 Plus/Gold BIKE

 to the PC, please use the USB data download 

cable and plug it both in the gauge’s USB port and in the PC’s USB port, as explained in the 
following figure. Moreover, 

we remind You to use a 9-15 Volts external power source

 to switch 

the gauge on. 

 

 

Figure 3: 

How to connect Your 

MyChron 3 Plus Gold Bike 

to the Pc 

 

Software 

 

Whenthe data logger has been installed and the sensors plugged in it, to acquire consistent and 
correct information, the data logger needs to be configured. For a correct configuration, please use 

Race Studio 2

, the software properly developed by Aim to configure its instruments and analyze 

stored data. 

 

In 

Race Studio 2

 main window, shown here on the right, 

You can choose your data logger. 
Please, select “MyChron 3 Plus/Gold” and, then, press 
“System manager” button 
 
Now, please follow these configuration steps: 
 

1.

 

Set the desired input channels; 

2.

 

Configure the input channels; 

3.

 

Transmit the configuration to the logger; 

4.

 

Calibrate/autocalibrate the sensors; 

5.

 

Transmit the configuration to the logger. 

 

 

 