                                                                                                                   MyChron 3 Plus/Gold BIKE - -Version 1.01 

3

1) How to set the input channels 

 
Press “Channels” button to set the sensors you have installed 
on your gauge. The following screenshot appears. 
 

 

 
To set an input channel, double-click on the cell 
corresponding to the desired one: the screenshot shown in 
the previous picture appears. 
Select the desired input channel among the available ones. 
 

2) How to configure the gauge 

 
Once set the desired input channels, press “Configuration” 
button to set RPM maximum value, temperature measure 
unit, RPM factor, split numbers etc… The following 
screenshot appears. 
 

 

 
To correctly configure your 

MyChron 3 Plus/Gold BIKE

 it 

is necessary to set all parameters reported in this dialog box: 
 

 

Display language. 

 

RPM multiply factor. 

 

Maximum RPM value. 

 

Temperature, pressure and speed measure unit. 

 

The alarm values for the 4 analog inputs. 

 

Pulses per wheel revolution. 

 

Wheel circumference. 

 

Obscuring time. 

 

Number of splits. 

 

Shift lights. 

 

Gear sensor (None, “On-board”, Calculated). 

 
Please, refer to the user’s manual to get further information 
concerning Yourgauge’s configuration. 

 

3) How to transmit the configuration

 

 
Once you set the input channels and configured them, you 
have to transmit the configuration to the instrument; to do so, 
please press “Transmit” button. 
We remind You that, to transmit the configuration, the gauge 
must be switched on and connected to the PC. 
 

4) How to calibrate/auto calibrate the sensors

 

 
When the configuration has been transmitted to the PC you 
have to calibrate/auto calibrate the sensors. 
The external gyroscope and the “potentiometer distance” 
need to be auto calibrated, while “Mid zero potentiometer”, 
“zero based potentiometer” and “on-board gear sensor” need 
to be calibrated. 
 
Please press “calibrate” button and the following screenshot 
appears. 
 

 

 
Please follow these instructions: 
 

 

G-force sensor and “potentiometer distance” sensor 
need to be auto-calibrated; to do so, please press 
button “Click here to autocalibrate all sensors in the 
list”. 

 

To calibrate “on-board” gear sensor, “Mid zero 
potentiometer” or “zero based potentiometer”, 
please click on the corresponding “Calibrate” button 
and follow the instructions prompted on your PC’s 
monitor. 

 

We remind You that calibration/auto calibration 
procedure is fundamental to acquire correct data.  

 

5) Re-transmit the configuration

 

 
When the calibration/auto calibration is finished, it is 
absolutely necessary to re-transmit the configuration to your 

MyChron 3 Plus/Gold BIKE

; to do so, please press 

“Transmit” button. 

 

 

 