13
OUTPUT-B: Signal Output Terminal Block
OUTPUT-B Pin and corresponding output mode:
•
A single unit is fastened completely (B1 & B4 are conductive)
•
OK screw fastening each time (B3 & B4 are conductive)
•
NG screw fastening each time (B2 & B4 are conductive).
•
No voltage contact signal (dry contact).
•
When WORK function is connected to the production line, I/P (B5, B6)
will be connected to the switch
JP-B: Signal Output Terminal Block for External Control ONLY
JP-B Pin and corresponding output mode:
•
Under the mode WORK I/P, B5 and B6 should be conductive in order to
operate. Both the AM Controller and the external controller can be
monitored by the operator at the same time. The signal of the sensor used in
the production line can be delivered to the AM Controller. When B5 and B6
are connected, the AM Controller can work independently as a monitor.
•
A5, A6: Start signal for automation ONLY. Use the external controller to
control the conduction and non-conduction between the screwing
manager and the electric screwdriver.