17
BLOW START/LEVER ON [Mpa]
(
Blow Start Pressure/ Fastening Start Pressure
)
・
Measurement Start Pressure
Initial Value
Shut-off Tool
: 0.10
TM Type Tool : 0.10
Standard Tool : 0.50
Setting Range 0.00~1.00
・
When using Shut-off Tool, the corresponding name will be BLOW START, and set a pressure
value to effect Tool blow detection.
・
When using TM Tool (not Shut-off) or Standard Tool, the corresponding name will be LEVER ON,
and set a pressure value to effect Tool free-running detection.
・
This setting is common among WORK No. 1~4.
SHUT-OFF/BLOW START [Mpa] (Shut-off Pressure/Blow Start Pressure)
Initial Value
Shut-off Tool
: 0.30
TM Type Tool : 0.20
Standard Tool : 0.30
Setting Range: 0.00~1.00
・
When using Shut-off Tool, the corresponding name will be SHUT-OFF, and set a pressure value
to effect Tool Shut-off signal detection.
・
When using TM Type or Standard Tool, the corresponding name will be BLOW START, and set a
pressure value to effect Tool blow detection.
・
This setting is common among WORK No. 1~4.
PULSE LV [Mpa] (Pulse Detection Pressure)
Setting Range
: 0.000~1.000
Initial Value
: 0.000
・
This is a setting to enable pulse detection.
・
PULSE Pulses of less than PULSE LV will not be counted.
・
Perform setting works under Auto Setting or by referring to waveforms saved on PC.
・
This setting is common among WORK No. 1~4.
※
Pulse detection will sometimes become impossible in the case that Tool of less pneumatic
pressure fluctuation type at pulsation (small tool or the like to be more specific) is in use or
depending on work conditions.
CUT PULSE No. (Cut Pulse Number)
Setting Range
: 0~999
Initial Value
: 0
・
In the case of 1~999 setting, Valve Output will take place when the pulse number input reached
the preset pulse number to stop Tool.
・
In the event that you do not use this function, make this setting 0.
・
This setting is common among WORK No. 1~4.