26
TIMER
①
INITIAL. E [msec]
(initial error detection timer)
Initial Value
: 0
Setting Range
: 0~9999 (0 setting when you do not use this function)
Functions
・
Timer will start at the time when the pressure attained the preset fastening start pressure, and
error will be detected when the preset shut-off pressure is attained before time-out.
・
This is on-a-WORK No. basis setting.
②
CYCLE. E. [msec] (cycle error detection timer)
Initial Value
: 0
Setting Range
: 0~9999 (0 setting when you do not use this function.)
Functions
・
Timer will start at the time when the pressure attained the preset fastening start pressure, and
cycle error will be detected before the preset shut-off pressure is attained.
・
This is on-a-WORK No. basis setting.
③
L. CONTR. [sec] (line control timer)
Initial Value
: 100
Setting Range
: 1~999
Functions
・
This function is used to effect fastening number count operation based on timer control.
・
This is on-a-WORK No. basis setting.
④
WARNING [sec] (alarm output timer)
Initial Value
: 0
Setting Range
: 0~999
・
Use this function when an alarm output before line control timer time-out timing is necessary.
・
Terminal outputs allocated to alarm outputs will turn ON before the alarm output timer preset
time from the line control timer time-out. Alarm outputs will turn OFF at the time of line
control timer time-out timing or at the time of Count OK (line control judgment).
・
This is on-a-WORK No. basis setting.
* * * TIMER * * *
■INITIAL.E.: 0msec
CYCLE.E.: 0 msec
L.CONTR.: 100 sec
WARNING : 0 msec
ON : 700 msec
OFF : 800 msec
OK : 1000 msec
COUNT OK: 1000 msec
1-PULSE : 10.0 msec
QL time : 100 msec