background image

2).  Under  voltage  protection:

  The  inverter  will  automatically  shut  down  when  the  input 

DC  voltage  is  lower  than  9.5V  for  12V  model  and  20V  for  24V  model.  The  buzzer  will 

whistle continuously and the green light is off, red light is on. Please turn off the inverter 

and use it after recharging the battery.  

3). Over voltage protection:

 The inverter will automatically shut down when the input DC 

voltage is higher than 16V for 12V model and 32V for 24V model. The buzzer will whistle 

continuously  and  the  green  light  is  off,  red  light  is  on.  Please  turn  off  the  inverter  and 

adjust the input voltage to the admissible range.

4).  Overload  protection:

  The  inverter  will  automatically  shut  down  when  the  load  is 

higher than the rated power. The buzzer will whistle continuously. Turn off the inverter and 

resume normal operation after taking away the excessive load.

5).  Short-circuit  protection:

 The AC  output  will  be  automatically  shut  down  when  short 

circuited. It will automatically reset after the problem is solved.

6). Thermal protection: 

The unit will get hot during operation. If the temperature is higher 

than 149°F or 65°C, the inverter will automatically shut down. Then the buzzer will whistle 

continuously  and  the  green  light  is  off,  red  light  is  on.  Please  turn  off  the  inverter,  and 

continue using it after the temperature goes back to normal naturally. Meanwhile find out 

the  factors  causing  the  fault,  such  as  ventilation,  ambient  temperature,  vent,  load  power 

and so on. It can avoid similar things from happening again.

Notice:

In  the  case  of  over  voltage,  under  voltage  and  thermal  protection,  the  inverter  will  shut 

down  automatically  after  1  minute  if  the  user  doesn't  turn  it  off  .  When  it  is  in  the  OFF 

position, the inverter doesn't consume battery current. 

Pure Sine Wave Output
(230 VAC Model)

312 Volta peak

7.

8.

6) The cooling fans inside the inverter do not work until the case temperature rises up to 

about  104°F

or

40°C.

7) Switch off inverter or remote to turn off. At that time, the indicator lights for both inverter 

and remote are off. The inverter does not consume current from the battery when it is 

switched off.

② 

 How to use USB power supply

        This  model  supplies  a  USB  output,  and  provides  stable  voltage  at  5V  DC,  maximum 

current 2.1A  directly to a portable device with USB port.

Notice: Before using the USB power supply, please make sure the device can be charged 

by USB and the maximum working current is no more than 2.1A.

8. About soft start technology

   The output voltage rises up from low to normal when the inverter is turned on. This can 

reduce high startup currents, which can make startup easier for large inductive loads.   

   As for the large inductive loads, such as electric tools and capacitive loads, we suggest 

turning on the switch of the appliance firstly and then the inverter's. The soft start may be 

enough to power the high startup.

9. The output wave form

       The  output  wave  form  of  this  inverter  is  a  Pure  Sine  Wave,  which  is  similar  to    utility-

supplied  AC  electricity.  Pure  sine  wave  is  applicable  in  most  loads,  including  electrical 

equipment, such as Linear Adaptor, switching power supply, transformer, motor and so on. 

   Compared to Modified wave form, for inductive loads such as a refrigerator and electric 

fans,  pure  sine  wave  form  can  improve  its  power  factor  and  the  battery's  efficiency  and 

reduce  working  noises.  For  capacitive  loads  such  as  adapter  of  lap-top,  pure  sine  wave 

can  lower  the  rush  current  at  work  and  reduce  interferences  to    increase  reliability  and 

prolong the life of the product.

10. Protection 

Features

1).  Input  under-voltage  alarm:

  When  the  input  DC  voltage  is  lower  than  9.8V  for  12V 

model  and  21.2V  for  24V  model,  the  buzzer  will  whistle  intermittently  to  remind  that  the 

inverter will go into the under voltage protection. Pay attention to save the data if you are 

using a computer. 

Summary of Contents for AIMS Power PE300012230S

Page 1: ...WARNING Please read this manual in its entirety before using or connecting this inverter It includes important instructions and safety tips Model number PE300012230S PE300024230S ...

Page 2: ...2x40A 12x20A 0 40 540x236x95mm 6 8kg 7 3kg boxed Temperatur 40 optional PE300012230S PE300024230S 12VDC 24VDC Model Power supply Voltage Output voltage Output frequency Output wave form Continuous power output Peak power output Under voltage safeguard Over voltage safeguard USB outlet Fuse Operating temperature Dimension LxWxH Weight Cooling fan Remote 230Vac 50Hz Pure sine wave 3000W 6000W 10VDC ...

Page 3: ...four screws 3 Mounting the remote control box Optional equipment 1 3 16 5 2 16 1 2 16 5 1 16 1 the remote is designed to be mounted on a dash or other surface where a hole should be cut so that it sits flush This is not a requirement however just a recommendation 2 The remote cable should be plugged into inverter and the remote before mounted Note Optional remote is not needed for inverter operati...

Page 4: ...In high current the input DC wire may produce a voltage drop therefore the operating voltage should be subject to the value on the terminals If the voltage drop is too large you can increase the cross sectional area or reduce the length of the lead 3 Connect cathode wire of the battery to the cathode terminal black on the rear panel of the inverter and then connect the anode wire of the battery to...

Page 5: ...6 The cooling fans inside the inverter do not work until the case temperature rises up to about 104 F or 40 C 7 Switch off inverter or remote to turn off At that time the indicator lights for both inverter and remote are off The inverter does not consume current from the battery when it is switched off How to use USB power supply This model supplies a USB output and provides stable voltage at 5V D...

Page 6: ...irst then open the inverter Use the internal soft start circuit of the inverter to buffer the start 11 Troubleshooting tips AIMS Power Warranty Instructions This product is designed using the most modern digital technology and under very strict quality control and testing guide lines If however you feel this product is not performing as it should please contact us techsupport aimscorp net or 001 7...