background image

7

GETTING STARTED

APPENDIX

USING THE SYSTEM 

(AT THE MASTER STATION)

USING THE SYSTEM

 (AT A SUB STATION)

 

How to use the magnetic room and name plates

NOTES:

Use an oil-based pen (a grease marker) to fi ll in the plate.

• 

When rewriting, be sure to remove the plate from the panel fi rst, and then wipe away the current contents with a soft cloth dampened with 

• 

rubbing alcohol. Do not use thinner.

Sub station

               Bedside handheld sub station (NI-RC)

      

               

Room plate (included)

Write information (e.g. room 

number) on the plate in the 

corresponding positions. 
Attach the plate on the 

corresponding position.

Nameplate (included)

Write information (e.g. name) on 

the plate. 
Attach the plate on the 

corresponding position.

Call button

Call button

Initiates a 
call.

Call 
indicator 
(red)

Lights up 
while calling 
the master 
station.

Microphone

RECEIVE VOL.

Adjusts the volume of 
audio from the master 
station to 3 levels (low/
mid/high).

Handle

Wall jack with hanger 
for NI-RC (NIR-HPF)

Hanger

Hang the handle of 
NI-RC here.

Speaker

Wall jack for NI-RC 
(NIR-HP)

Attach the hanging 

bracket to a side-rail of 

bed with the screws

Hang the handle of the unit 

on the hanging bracket.

Connect and fasten the 

plug to a wall jack.

Screw x 2 (included)

Main unit

Hanging bracket (included)

Wall jack
*  Only NIR-HP or NIR-HPF 

is available.

*  If NIR-HPF is used, the 

hanging bracket may not 
be needed.

 

Installing the bedside handheld sub station (NI-RC)

Cord: Approx. 1.5m (5')

Cord: 

Approx. 1.4m (4.6')

NOTE: 

If the call button has a cord, do not loop it around the bed 

• 

frame. It may become disconnected.

If the plug is not fastened securely, the cord may be 

• 

disconnected easily or it may cause a malfunction. Confi rm 
that the plug is fastened to the jack securely once again.

Summary of Contents for NIM-20B

Page 1: ...our communication needs Please make sure to read this manual for safe and correct use of the system and keep it in a safe place for future reference Please note that images and illustrations depicted...

Page 2: ...USING THE SYSTEM AT THE MASTER STATION 11 Answering a call 11 When receiving a single call 11 When receiving multiple calls 12 Calling sub stations 13 Calling a single sub station 13 Paging 14 Adjusti...

Page 3: ...electric fields GENERAL PRECAUTIONS 1 The unit is inoperative during power failure 2 In areas where broadcasting station antennas are close by this system may be affected by radio frequency interferen...

Page 4: ...North America only Call extension speaker IER 2 Power supply unit IS PU only PC for call log software NI SOFT Corridor light single bed NIR 4 NIR 4 Call reset button NIR 2 NIR 2 Ceiling speaker NI LB...

Page 5: ...ods The following two methods are available on the master station Method Communication style Description Using handset Voice actuated communication The communication mode is VOX half duplex When speak...

Page 6: ...nes audio from a sub station and alarms are heard from here Turn off the POWER switch when the system malfunctions Microphone Sends audio from this station to other stations OFF button OFF Press to en...

Page 7: ...ed Lights up while calling the master station Microphone RECEIVE VOL Adjusts the volume of audio from the master station to 3 levels low mid high Handle Wall jack with hanger for NI RC NIR HPF Hanger...

Page 8: ...hone for NIR 8 NIR MB Call latching wall jack for NIR 8 NIR 7BS Call indicator red Speaker Microphone Wall jack for NIR 8 NIR 1 Bedside call switch NIR 8 Connect and fasten the plug to a wall jack Wal...

Page 9: ...single bed NIR 4 Corridor light multiple beds NIR 4S Call reset button NIR 2 Corridor light with reset button NIR 42 Corridor light with buzzer NIR 4BZ Lamp red Lamp red Reset button Buzzer Pull cord...

Page 10: ...responding sub station Nameplate See below Room number plate See below Lamp red Reset button Corridor light with nameplates 2 names NIR 32 Corridor light with nameplate 1 name NIR 31 Room number plate...

Page 11: ...more call indicators are lit on a corridor light pressing the reset button turns off all the indicators USING THE SYSTEM AT THE MASTER STATION The ringtone sounds The call in talk indicator for the c...

Page 12: ...s the reset button for the calling station The call indicator on the calling station and the corresponding indicators on the master station turn off When two or more call indicators are lit on a corri...

Page 13: ...begin talking NIM system To speak Press and hold TALK while speaking To listen to the user of the sub station Release TALK while listening To end the communication press 3 OFF NIM system The call in t...

Page 14: ...peaking NIM system Do not release TALK until you end speaking A notice sound is heard at all the sub stations To end the paging press 3 OFF NIM system NOTES Paging will end automatically after 90 seco...

Page 15: ...ent communication There is communication only if a sub station or speaker microphone is installed in the calling location While speaking on the master station the TALK indicator is lit audio from the...

Page 16: ...ly after 90 seconds Calling the master station Press the call button 1 The type of call button differs depending on the equipment used in your application When the master station answers begin talking...

Page 17: ...s SPCC Color Panel White Chassis Green mist Dimensions NIM 20B 330 W x 230 H x 140 D mm 13 W x 9 1 16 H x 5 1 2 D NIM 40B 480 W x 230 H x 140 D mm 18 7 8 W x 9 1 16 H x 5 1 2 D 60 call 630 W x 230 H x...

Page 18: ...lbs Bedside call switch NIR 8 Ambient temperature 0 40 C 32 F 104 F Material Plastic Color White Dimensions 36 x 95 H mm 1 7 16 x 3 3 4 H Weight Approx 90g 0 2 lbs Wall jack for NIR 8 NIR 1 Ambient t...

Page 19: ...ht Approx 85g 0 19 lbs Corridor light with reset button NIR 42 Power source Supplied from the master station Ambient temperature 0 40 C 32 F 104 F Mounting Wall flush mount Electrical box 2 gang box M...

Page 20: ...will not be responsible for any costs incurred involving on site service calls Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products dur...

Reviews: