NOTE:
Release contacts on the JF-2MED are from
4-pin connector included with unit.
Connect Red & Brown wires as shown.
Orange & Yellow wires are not used.
Release contacts on the JK-1MD/MED
are L/L terminals.
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Toll Free Technical Support:
1-800-692-0200
E-mail tech-serv@aiphone.com
RY-18L Instr.
0310JD
SPECIFICATIONS:
Power Source:
Supplied by master station
Mounting:
No mounting required
Terminations:
Color-coded prewired pigtails
Relay Input:
12-18V DC, Red, Gray wires, 22AWG
Relay Output:
Brown, Red, Orange wires, 18AWG
N/O Output rating:
5A at 30V DC
10A at 125V AC
3A at 250V AC
N/C Ouptut rating:
3A at 30V DC or 125V AC
Wiring:
2 conductors from monitor's door release contacts to RY-18L.
2 conductors from RY-18L to strike, with power for strike wired in series.
Dimensions (HxWxD): 1-3/4" x 7/8" x 7/16", with wires extending approx. 7-1/2"
WIRING DIAGRAMS:
A1
A2
B1
B2
S
S
DC 18V
+
-
RELEASE
(L)BRN
(L)RED
JK-1MD/MED
JF-2MED
Door
A1
A2
PS-1820UL
+
-
.
Red
Gry
Brn
Org
Yel
COM
N/O
N/C
Use Normally Open
contact for electric strike
ELECTRIC STRIKE
WIRING METHOD:
JF/JK OPEN VOICE COLOR VIDEO SYSTEM:
PS-1820UL
+
-
.
Red
Gry
Brn
Org
Yel
COM
N/O
N/C
Use Normally Closed
contact for magnetic lock
MAGNETIC LOCK
WIRING METHOD:
A1
A2
B1
B2
S
S
DC 18V
+
-
RELEASE
(L)BRN
(L)RED
Add
jumper
wire from
BRN to +
Add
jumper
wire from
BRN to +
NOTE:
Only wiring pertaining to connection of door
release relay is shown here.
For complete system information, please
consult the main system installation manual.
JK-1MD/MED
JF-2MED
+ -
LOCK
POWER
+ -
LOCK
POWER