background image

TC-20M

TC-10M

TB-SE
TB-SE-R

TC-20G

TC-40G

 Master stations

 Add-on selectors

 Sub stations

 Power supplies

PS-18C

 (AC 120V)

PS-18E

 (AC 220 ~ 240V)

 Door station adaptors

TB-AD1

TB-AD10

Notes;
1.  TC-M & TC-G units can not interchangeably be used with TB-M & TB-G units.
2.  TC-M masters & accessories are NOT compatible with TB-10T and TB-20T.
3.  TB-RC sub station (for TB-T) can be used with TB-M & TC-M masters.
4.

Video accessories;

     TC-M system may be combined with a TB-ADM10 video adaptor, which can connect 
     up to 10 video door stations MK series (MK-DAC, MK-DBC, MK-DS/B), etc.  Install a 
     video monitor MYH-CU beside TC-M.  For details, refer to the Manual packed with TB-ADM10.

 Call extension

IER-2

 External signaling relay

TAR-3

IF-DA

TC-10M
TC-20M
TC-20G
TC-40G
TB-SE
TB-SE-R
IER-2
TAR-3

TB-AD1
TB-AD10
IF-DA
PS-18C
PS-18E

10-call master
20-call master
20-call add-on selector
40-call add-on selector
Handset sub station
Handset sub station, red case
Call extension speaker (for TC-M)
External signaling relay 
(Requires a 6V DC power supply)
1-call door station adaptor
10-call door station adaptor
Door station (any IE/IF series)
18V DC power supply (AC 120V)
18V DC power supply (AC 220 ~ 240V)

TC-10M or TC-20M
w/TC-20G or TC-40G

IF-DA

TB-AD1

TB-SE

ea. 2

or

TB-SE

TB-SE

TB-SE

2

5

– 2 –

1

System outline

The TC-M is an internal telephone type system, expandable up to 60 subs and 2 masters.
Communicates with TB-SE handset subs and IE/IF door stations.

1

Package contents

1

Master station (TC-10M or TC-20M)

2

Directory card & cover

3

Screws-pack (2 types, ea. 4 pcs)

4

Wall-mount cradle

5

Installation & Operation Manual

Summary of Contents for Tc-10m

Page 1: ...r SA 1 is available from Aiphone 1 Do not connect any power source other than specified on TC M master Fire or damage to the unit could result 2 Do not open TC M master High voltage is present inside...

Page 2: ...g relay TAR 3 IF DA TC 10M TC 20M TC 20G TC 40G TB SE TB SE R IER 2 TAR 3 TB AD1 TB AD10 IF DA PS 18C PS 18E 10 call master 20 call master 20 call add on selector 40 call add on selector Handset sub s...

Page 3: ...ide of master Features TC 20G or TC 40G add on selector connects additional TB SE subs allowing system expansion One or dual master configuration TB AD1 adaptor connects TC M with an IE IF Series audi...

Page 4: ...om TB SE terminal 2 2 wires from TB SE subs must not be made common at any other point than on the TC M terminal block 1 12V 2 3 4 5 6 7 8 9 10 E E E E E E C M R R T T S S 1 12V 2 3 4 5 6 7 8 9 10 E E...

Page 5: ...sub s station number numbered from the top on each 10 button row 2 parallel wires per TB SE sub nonpolarized Be sure to run each pair of wires directly to TC M master E line in each pair should not be...

Page 6: ...3 1 2 E 4 1 2 E 5 1 2 E 6 1 2 E 7 1 2 8 1 2 E 9 1 2 10 1 2 TB SE Sub station TC 10M Master station S S Connector To power supply Do not connect any power source here IN AC 15 16V or DC18V 12V OUT Desi...

Page 7: ...D6 1 2 E D7 1 2 D8 1 2 E D9 1 2 D10 1 2 IF DA E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 1 2 1 2 3 4 5 6 7 8 9 10 12V T R S S To power supply Do not connect any power source here IN AC 15 16V or...

Page 8: ...larized To power supply Do not connect any power source Designate any terminal for TB AD1 Call extension IER 2 1 E Call extension IER 2 1 E Common TB SE sub rings two TC M Masters Each master can call...

Page 9: ...zer is activated and on TB SE sub call tone sounds at reduced volume TAR 3 relay activates an AC operated buzzer AC 240V 0 3A DC operated buzzer must be mechanical type DC 24V 1 0A Do not use DC elect...

Page 10: ...ll TC M leaves sub A waiting pressing a sub B select button When sub B picks up the call sub A hears a busy tone TC M depresses Transfer switch TC M then reselects waiting sub A with red LED on Three...

Page 11: ...eive and call tone volume Upper control adjusts handset receiver volume when TC M does not hear a TB SE sub clearly Tone control adjusts ringing tremolo 3 levels TC M dual master system Two masters ca...

Page 12: ...be responsible for any costs incurred involving on site service calls 8 8 SPECIFICATIONS Power source DC18V 350mA max or AC 15 16V 50 60Hz 750mA max Power consumption 6W max 3W standby Capacity 60 sta...