F
Configuration Parameters
F.1 Own Aircraft
F.1.1 Own ICAO Address (HEX)
Description
To identify signals from the own transponder, AT-1 uses the aircraft’s unique ICAO 24 bit
address, also called ’HEX Code’. Entering this code is mandatory for AT-1 to function properly.
If your aircraft does not have an ICAO address, for example, because you do not have a
Mode-S Transponder or 406MHz ELT installed and, therefore, no ID has been assigned to
your aircraft yet, please enter ’FFFFFF’ instead.
•
Item Code:
ACFTADDR
•
Valid Values:
6-digit hex number
•
Default Value:
FFFFFF
F.1.2 Own Aircraft Category
Description
Configure the category of aircraft the AT-1 is installed in. This parameter adjusts warning
thresholds to suit the operational requirements of the aircraft category.
•
Item Code:
FLARMACFT
•
Valid Values:
integer value, 0 - 15
•
Default Value:
8
60