 Technical specifications

 

   A&S-300 Air purifier

 

Dimensions:

 

Width 406 mm .......................................... 406 mm

 

Depth 188 mm ........................................... 188 mm

 

Height 625 mm .......................................... 625 mm

 

Weight 8.9 kg ..............................................8,9 kg

 

Power supply ....................................... 

V~240 V 50HZ

 

Power consumption .................................... 

55 W

 

Noise level (dB):

 

High  .............................................................. 58 
Medium ........................................................ 30 
Low  ............................................................... 18  

 

Ventilation power:

 

High ................................................ de 5,8  à  6,8 m/s

 

Medium .......................................... de 3,5  à 4,5 m/s

 

Low ................................................ de 3,5  à 4,5 m/s

 

Maximum surface treated .................................. 80 m2

 

CADR ...................................... 320 m3/h (for  PM2.5)

 

 
 
 
 
 
 

 

 

 

 

Im

p

ri

m

é

 en

 F

ra

n

ce

 -

 É

di

tio

Ja

n

2021

 -

 P

h

o

to

co

p

yr

ig

h

A

ir

 et

 s

a

n

 

Summary of Contents for A&S 300 PREMIUM

Page 1: ...Air Purifier A S 300 PREMIUM User manual ...

Page 2: ... and retains gaseous pollutants volatile organic compounds Catalysis photocatalysis transforms pollutants into carbon dioxide and water steam Photocatalysis and UV UV lamps activate titanium dioxide and degrade pollutants into carbon dioxide and water steams Negative ions charged they aggregate with pollutants and cause them to fall to the ground Your purifier can be used continuously in this case...

Page 3: ...ents Safety advice 1 Precautions before first use 2 Quick start 2 Explanation of controls 3 Regular maintenance 4 Cleaning the particle detector 4 Filter s replacement 4 UV lamps replacement 6 Malfunctions 6 Recycling 7 Maintenance ...

Page 4: ... Do not touch your air purifier with wet hands and do not allow any liquids to get into it Never cover your air purifier Never block any part of the air inlet and outlet vents If you plan to stop the appliance for a long period of time turn it off and unplug it Before maintenance cleaning or performing any other work on your air purifier disconnect the power supply If you are unsure whether your a...

Page 5: ...d Do not place your air purifier behind curtains under a window under furniture on a shelf or near any other obstacle that may affect its proper functioning Check the condition of the power outlet to which you wish to connect your air purifier Your air purifier is not suitable for humid rooms such as bathrooms Your air purifier does not replace a kitchen hood ...

Page 6: ...ent indicator Timer the unit automatically adjusts its operation to the ambient air quality The timer can be set to 1h 4h 8h The power supply turns off when the time has elapsed Reset activates night silent function the appliance automatically switches to low speed switches off the air quality indicator light and deactivates the dust sensor enables to reset you have changed the filter switches off...

Page 7: ...regular intervals To keep the particle sensor working properly clean it regularly with a cotton cloth Cleaning the particle detector The detector s room should be cleaned from time to time with a cotton cloth first humid and then dry to absorb the remaining moisture Around every two months depending on your environment Filter replacement The filters should be replaced when the change indicator on ...

Page 8: ...ut it in place 4 Put the pre filter in place and hear the click 5 Put the front cover in place making sure that the safety lock on the front base of the purifier is properly in place 6 Plug in the electrical outlet 7 Press the Reset button for 5 seconds Safety precautions we recommend that you protect yourself during this operation by wearing a surgical mask and washing your hands well after the p...

Page 9: ...r The appliance does not start Verify the power supply The volume of air produced seems low Verify the cleanliness of the filters Make sure that the plastic protection films of the filters have been removed The air quality is not improving despite a long running time Replace the filters After closing the cover the purifier will not start again Verify that the safety system on the inside of the cov...

Page 10: ...ver when replacing them it is preferable to put them in a garbage bag and tie it up tightly before throwing it with the regular garbage Recycling program AIR ET SANTÉ Concerned about the environment AIR ET SANTÉ ensures the recycling of the machines when they reach their life cycle You will find on our website all the useful information to guarantee the optimal recycling of your machine ...

Page 11: ...9 Manuel A S 300 Air outlet Quality indicator of air control Screen particles detector Air inlet Safety contact ...

Page 12: ...and skin irritation dizziness as well as allergic reactions and asthma In 30 years the number of allergies has tripled and the number of asthmatics has quadrupled reaching 20 to 25 of the population There are about 28 000 new cases of illnesses asthma rhinitis per year linked to poor indoor air quality To contact us Phone number 33 0 9 72 64 67 16 from 9h00 to 18h00 Email support air and health co...

Page 13: ...mm Weight 8 9 kg 8 9 kg Power supply V 240 V 50HZ Power consumption 55 W Noise level dB High 58 Medium 30 Low 18 Ventilation power High de 5 8 à 6 8 m s Medium de 3 5 à 4 5 m s Low de 3 5 à 4 5 m s Maximum surface treated 80 m2 CADR 320 m3 h for PM2 5 Imprimé en France Édition Jan 2021 Photos copyright Air et santé ...

Reviews: