background image

INSTALLATION

IMPORTANT:

- This gun should be operated by adequately trained operators only.
- Ensure that the gun has not been damaged during transportation.
- Clean dry air should be supplied to the gun.

1. Connect an air hose to air hose joint tightly.
2. Flush the gun fluid passage with a compatible solvent.
3. Test spray, and adjust fluid output as well as pattern width.

HOW TO OPERATE

Set the spray distance from the gun to the workpiece as near as
possible within the range of 150 - 200 mm.(From 5.9 to 7.7 inch) 
The gun should be held so that gun is perpendicular to the surface
of the workpiece at all times.

MAINTENANCE AFTER PAINTING

1) Pour remaining paint into another container and then clean paint passages and air cap. Spray a small amount 
of thinner to clean paint passages. Incomplete cleaning will cause bad operations. Clean fully and promptly paint
after use.
2) Clean other sections with attached brush soaked with thinner and waste cloth.
3) Clean paint passages fully before disassembly.

SAFETY WARNINGS

1. Fluid and solvents can be highly flammable or combustible.

- Use in well-ventilated spray booth.
- Avoid any ignition sources such as smoking, open flames, electrical hazard, etc.

2. NEVER use HALOGENATED HYDROCARBON SOL-

VENTS (1.1.1 T

RICHLORINE

ETHYL CHLORIDE

, etc.), which

can chemically react with aluminium and zinc parts and
cause an explosion. Be sure that all fluids and solvents
used are chemically compatible with aluminium and zinc
parts.
If in doubt, consult your fluid or solvent supplier to ensure compatibility. Details of materials used in the gun are avail-
able on request.

3. To reduce the risk of static sparking, grounding continuity to the spray equipment and object being sprayed must be

maintained.

1. NEVER point gun in the direction of human body.

2. NEVER exceed the maximum safe working pressure of the equipment.

3. ALWAYS release air and fluid pressures before c!eaning, disassembling or servicing. For emergency stop and pre-

vention of unintended operation, a ball valve installation near the gun to stop air supply is recommended.

1. Toxic vapours produced by spraying certain materials can create intoxication and serious damage to health.

- Use the gun in well-ventilated areas.
- Always wear protective eyewear, gloves, respirator, etc., to prevent the toxic vapour hazard, solvents and paint

from coming into contact with your eyes or skin.

2. Noise level mentioned in main specifications was measured at 1.0 m behind the tip of the gun, 1.6 m height from floor.

- Wear earplugs if required.

1. NEVER enter working areas of robots, reciprocators, conveyors, etc., unless machines are switched off.
2. NEVER spray foods or chemicals through the spray gun.
3. NEVER modify this product for any applications.

2

3

FIRE OR EXPLOSION HAZARD

MISUSE HAZARD

HAZARD CREATED WHILE COATING MATERIALS ARE ATOMIZED AND SPRAYED

OTHER HAZARDS

WARNING 

NEVER USE COMMERCIAL OR OTHER PARTS INSTEAD OF AIR GUNSA ORIGINAL SPARE
PARTS
NEVER IMMERSE THE WHOLE GUN INTO LIQUID SUCH AS THINNER

WARNING 

TURN OFF AIR AND COATING MATERIALS TO THE GUN AND RELEASE PRESSURE BY TRIG-
GERING THE GUN BEFORE DISASSEMBLING, CLEANING OR SERVICING.

PAY ATTENTION WHEN DISASSEMBLING SPRAY GUN SINCE YOU MUST TOUCH SHARP PARTS.
BEFORE DISASSEMBLING READ CAREFULLY THIS INSTRUCTION MANUAL. 

Summary of Contents for AZ PVA

Page 1: ... BRANCHES Max Working Pressure 6 bar 8 58 PSI Noise Level LAeqT 87 3 dB A Temperature range 5 40C Instruction Manual ANEST IWATA Europe S r l Corso Vigevano 46 10155 Torino Italy Tel 011 24 80 868 4 linee ric aut Fax 011 85 19 44 ANEST IWATA France S A 38074 Saint Quentin Fallavier Cedex Centre Evolic B P 7405 Tél 04 74 94 59 69 Fax 04 74 94 34 39 ANEST IWATA U K LTD Unit 2 Cedar Trade Park Ferndo...

Page 2: ...Details of materials used in the gun are avail able on request 3 To reduce the risk of static sparking grounding continuity to the spray equipment and object being sprayed must be maintained 1 NEVER point gun in the direction of human body 2 NEVER exceed the maximum safe working pressure of the equipment 3 ALWAYS release air and fluid pressures before c eaning disassembling or servicing For emerge...

Page 3: ...at may be necessary GB MAIN SPECIFICATIONS EUROPEAN SALES BRANCHES Max Working Pressure 6 bar 8 58 PSI Noise Level LAeqT 81 3 dB A Temperature range 5 40C Instruction Manual ANEST IWATA Europe S r l Corso Vigevano 46 10155 Torino Italy Tel 011 24 80 868 4 linee ric aut Fax 011 85 19 44 ANEST IWATA France S A 38074 Saint Quentin Fallavier Cedex Centre Evolic B P 7405 Tél 04 74 94 59 69 Fax 04 74 94...

Page 4: ...Details of materials used in the gun are avail able on request 3 To reduce the risk of static sparking grounding continuity to the spray equipment and object being sprayed must be maintained 1 NEVER point gun in the direction of human body 2 NEVER exceed the maximum safe working pressure of the equipment 3 ALWAYS release air and fluid pressures before c eaning disassembling or servicing For emerge...

Reviews: