2084008
Rev. K 11/07
2
11
2084008
Rev. K 11/07
SPECIFICATIONS
Motor .................................120V, 60 Hz
Blade diameter ..................20" ( 50.8 cm)
Speeds ...............................3
Control ...............................Rotary Knob
Approvals ...........................ETL Listed. Close mesh fan guard
meets OSHA requirements.
DESCRIPTION
The Air King
®
20" (50.8 cm) Box Fan features 3-speed rotary knob
operation, rounded corners. The 20" ( 50.8 cm) 5-paddle blade is driven
by a permanent lubricated motor with a 6 foot (1.8 m) 18/3 cordset.
MODEL
4CH71F/9723F
SPEED
HIGH
MED
LOW
CFM
2163
1900
1463
M
3
/s
1.02
0.90
0.69
RPM
1220
1075
855
Amps
0.94
0.72
0.56
Watts
105
87
65
dB A
60
55
51
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire, elec-
tric shock and injury to person, including the following:
1. Read all instructions before using Fan.
2. Make certain that the room is equipped with a working smoke
detector.
3. Use this Fan only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electrical
shock, or injury to persons.
4. Unplug power cord before installing, servicing, or moving the
Fan.
WARNING:
DO NOT DEPEND UPON THE ON-OFF SWITCH AS
THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALL-
ING OR SERVICING THE FAN. ALWAYS UNPLUG THE POWER
CORD.
5. This Fan must
NOT
be used in potentially dangerous
locations such as flammable, explosive, chemical-laden
or wet atmospheres.
6.
DO NOT
use Fan in or near a window. Rain may create an
electrical hazard.
7. The power cord is equipped with a three-prong grounded plug
that must be inserted into a matching receptacle. Under
no circumstances must the grounding prong be cut off the
plug. Where a two-prong wall receptacle is encountered, it must
be replaced with a properly grounded three-prong receptacle
installed in accordance with the National Electrical Code
(NEC) and all applicable local codes and ordinances. This
work must be done only by a qualified electrician, using cop-
per wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER
IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CRE-
ATE THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS
IS NOT PERMITTED IN CANADA.
WARNING: THIS PLUG IS A SAFETY FEATURE. TO REDUCE
THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY,
DO NOT REMOVE, REPLACE, REPAIR OR TAMPER WITH
THE ORIGINALLY SUPPLIED PLUG. IF THE FAN DOES NOT
FUNCTION PROPERLY, IT MAY BE DUE TO THE SAFETY DEVICE
INCORPORATED IN THIS PLUG. CONTACT YOUR GRAINGER
DISTRIBUTOR.
8. Where possible, avoid the use of extension cords. If they must
be used, minimize the risk of overheating by ensuring that they
are UL listed.
NEVER
use a single extension cord to operate
more than one Fan.
9.
DO NOT
operate any Fan with a damaged cord or plug or
after the Fan malfunctions, has been dropped or damaged
in any manner. Return Fan to authorized service facility for
examination, electrical or mechanical adjustment or repair.
10.
DO NOT
insert or allow fingers or foreign objects to enter any
ventilation or exhaust opening as it may cause an electric shock
or fire, or damage the Fan.
DO NOT
block or tamper with the
Fan in any manner while it is in operation.
11.Always place the Fan on a stable, flat, level surface when
operating, to avoid the chance of the Fan overturning. Locate
the Power Cord so the Fan or other objects are not resting on
it.
DO NOT
run Power Cord under carpeting.
DO NOT
cover
Power Cord with throw rugs, runners, or the like. Arrange
Power Cord away from room traffic and where it will not be
tripped over.
12.This Fan is not intended for use in wet or damp locations.
Never locate a Fan where it may fall into a bathtub or other water
container.
13.
DO NOT
use Fan outdoors.
14.This Fan is not suitable for use in agricultural facilities including
areas where livestock, poultry or other animals are confined.
Please refer to National Electric Code (NEC) Article 547-7
(2008), or applicable state or local codes or standards relating
to electrical requirements for Agricultural Buildings.
THIS FAN
DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE
547-7 (2008).
15. This Fan is not suitable for use in hazardous locations. Please
refer to National Electric Code (NEC) Article 500 or applicable state
or local codes or standards relating to electrical requirements
for Hazardous locations.
THIS FAN DOES NOT MEET THE
REQUIREMENTS OF NEC ARTICLE 500 (2008).
WARNING:
REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE
SPEED CONTROL DEVICES.
SAVE THESE INSTRUCTIONS
MODEL 4CH71F/9723F
MODÉLE 4CH71F/9723F
OPERATION
1. Brancher le ventilateur dans une prise de courant standard à 120 Vca.
2. Régler la vitesse désirée à l'aide de l'interrupteur rotatif.
MAINTENANCE
AVERTISSEMENT: TOUJOURS DEBRANCHER LE CORDON D'ALIMENTATION AVANT D'EFFECTUER UN SERVICE.
NETTOYAGE:
Utiliser un chiffon doux et une solution à base de détergent doux comme du liquide pour la vaisselle.
NE JAMAIS IMMERGER DES PIECES ELECTRIQUES DANS L'EAU.
AVERTISSEMENT:
Ne pas utiliser d'essence, de benzène, de nettoyeurs forts, etc., qui vont endommager le ventilateur.
Sécher complètement toutes les pièces avec un chiffon doux avant de rebrancher l'alimentation.
RANGEMENT:
Ranger le ventilateur dans un endroit frais et sec.
LE MOTEUR EST LUBRIFIE EN PERMANENCE.
1
8
9
11
6
7
5
4
3
2
1
10
LISTE DES PIECES DE REMPLACEMENT
No
No
de réf de pièce Description Qte.
1
2091119
Vis #6 x 0,9 cm PPH type AB ZP
12
2
2018001
Grille arrière
1
3
2011405
Poignée
1
4
2011402
Bouton
1
5
2061713
Châssis du ventilateur
1
6 02050031WFPB Cordon d'alimentation uniquement 1
7
02031246S
Moteur avec interrupteur
1
8
2011278
Lame
1
9
2018000A
Grille avant
1
10
2091211
Vis #10 x 1,3 cm PPH Type A
4
11
2091118
Vis #6 x 0,9 cm PPH Type AB Grn
1