background image

SPECIFICATIONS

Motor .............................. 120V, 50/60 Hz
Blade Diameter .............. 9" ( 22.9 cm)
Speeds ........................... 2
Control ........................... Rotary Knob
Air Flow Distribution ....... 360

°

 Variable

Approvals ....................... UL listed. Close mesh fan guard meets

OSHA requirements.

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.  FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

 

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

DESCRIPTION

The Airking 9" (22.9 cm) Pivot features 3-speed rotary knob
operation, 360

°

 adjustable tilt stand.  The 9" ( 22.9 cm) 3-paddle

blade is driven by a permanent prelubricated motor with a 6' (1.83
m) 18/3 cordset.

OPERATING INSTRUCTIONS & PARTS MANUAL

GENERAL SAFETY INFORMATION

1. Make certain that the power source conforms to the electrical

requirements of the fan.

2. The power cord is equipped with a three-prong grounded plug

that must be inserted into a matching receptacle.  Under no
circumstances must the grounding prong be cut off the plug.
Where a two-prong wall receptacle is encountered, it must be
replaced with a properly grounded three-prong receptacle

installed in accordance with the National Electrical Code (NEC)
and all applicable local codes and ordinances.  This work must
be done only by a qualified electrician, using copper wire only.

WARNING:  USE OF A THREE-PRONG TO TWO-PRONG
ADAPTER IS NOT RECOMMENDED.  IMPROPER CONNECTION
MAY CREATE THE RISK OF ELECTROCUTION.  USE OF SUCH
ADAPTERS IS NOT PERMITTED IN CANADA.

3. Where possible, avoid the use of extension cords.  If they must

be used, minimize the risk of overheating by ensuring that they
are UL listed and of the proper gage and length.  Never use a
single extension cord to operate more than one fan.

4.  Do not insert fingers or foreign objects into the fan.  Do not block

or tamper with the fan in any manner while it is in operation.

5. To avoid the possibility of overturning the fan, ensure that it is

operating on a stable, level surface.

6. Unplug power cord before installing or servicing the fan

7. Completely reassemble fan, according to instructions, before

reconnection to power supply.

WARNING:  DO NOT DEPEND UPON THE ON-OFF SWITCH
AS THE SOLE MEANS OF DISCONNECTING POWER WHEN
INSTALLING OR SERVICING THE FAN.  ALWAYS UNPLUG
THE POWER CORD.

8. This fan is intended for general use ONLY.  It must NOT be

used in potentially dangerous locations such as flammable,
explosive, chemical-laden or wet atmospheres. DO NOT use
fan in a window.  Rain may create an electrical hazard.

WARNING:  TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT USE THIS FAN WITH ANY SOLID STATE
SPEED CONTROL DEVICE.

OPERATION

1. Plug the fan into any standard 120V AC household outlet.

2. Using the rotary switch, set the desired fan speed.

3. To rotate fan, loosen knobs on side of grill and tilt to direct

air flow.

MAINTENANCE

WARNING: ALWAYS UNPLUG THE CORD BEFORE MOVING
OR SERVICING THE FAN.

CLEANING

1. Use a soft cloth moistened with a mild soap solution. 

 NEVER

IMMERSE ELECTRICAL PARTS IN WATER. 

 Avoid use of

gasoline, benzine, thinner, chlorinated solvents, harsh clean-
ers, etc. This will result in damge to the fan.

9" (22.9 cm) PIVOT FAN

MODEL 4CH69/9525

MODEL

4CH69/9525

SPEED

HIGH

LOW

CFM

1140

880

M

3

/s

.54

.42

RPM

2449

1883

Amps

.57

.39

Watts

 37

27

dB A

 48

37

Rev. B 8/00

1

2084014

MODELO 4CH69/9530

Rev. B 8/00

4

2084014

LUBRICACIÓN

Los cojinetes de precisión vienen sellados de fábrica de por vida y no
requieren de lubricación adicional.

ALMACENAMIENTO

Cuando no esté en uso, guarde la unidad en un lugar limpio y seco.

ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIOS O
DESCARGAS ELÉCTRICAS, NO USE ESTE VENTILADOR CON
NINGÚN DISPOSITIVO DE CONTROL DE VELOCIDAD DE ESTADO
SÓLIDO.

1

4

10

2

8

12

5

13

11

15

9

3

14

6

7

16

7

6

REF

NO.

NO. DE
PARTE

DESCRIPCIÓN

CANT.

1

208

Parrilla Delantera Plastico

1

2

2011851

Parrilla Tracera Plastico

1

3

2011852

Armadura De Plastico

1

4

2011853

Aspa De 9 Pulgagas

1

5

2091501

Abrazadera

1

6

2011854

Boton Adjustable

2

7

2011856

Arandela De Goma

2

8

2011721

Boton Interruptor

1

9

2010403A

Pies De Goma

4

10

2057062

Interruptor, 2 Velocidade

1

11

2060100

Placa Montadura

1

12

2050042WT

Cordon Electrico

1

13

2090039

Tornillo #8 x 3/8" PPH

4

14

3091112

Tuerca Tipo Hex #8-32

2

15

2030057

Ensamble Del Motor

1

16

2070024G

Ornamento (AirKing)

1

la cabeza del ventilador. Saque los botones y los aros interiores de

caucho. Tire suavemente de los extremos del yugo hasta que salgan
y saque los ejes roscados de los orficios del yugo. Agarre suavemente
la parte superior e inferior del ventilador. Presione lentamente sólo
hasta que las cubiertas se desmonten. Limpie las aspas del ventilador
con un paño humedecido. NO DEJE QUE EL AGUA ENTRE EN EL
MOTOR. Vuelva a instalar las rejillas tal como se habian montado
anteriormente invirtiendo el orden seguido para desmontarlas.
Asegúrese de que el ventilador esté completamente seco antes
de enchufarlo.

LISTA DE REPUESTOS