background image

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. 

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions

should always be followed to reduce the risk of fire,

electric shock and injury to person, including the following:

SAVE THESE INSTRUCTIONS

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK 

AND INJURY TO PERSON, OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer.If 

you have questions, contact the manufacturer.

b)  Before servicing or cleaning the unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK 

AND INJURY TO PERSON, OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-related construction.

b)  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent back drafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA) and the 

American Society for Heating, Refrigeration, and Air Conditioning 

Engineers (ASHRAE), and the local code authorities.

c)  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

d)  Ducted fans must always be vented to the outdoors.

e)  If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application and be connected to a GFCI 

(Ground Fault Circuit Interrupter) - protected branch circuit.

f)  This unit must be grounded.

g)  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power unit.

h)  Suitable for use with electronic speed control device.

i)  Do not install into ceilings thermally insulated to a value greater 

than R40.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. DO NOT 

USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND 

VAPORS.

WARNING:

 

DO NOT USE IN KITCHENS.

k)  Read all instructions before installing or using exhaust fan.

www.airkinglimited.com

A210952017 Rev. B 8-12

1 of 12

In-Line Exhaust Fan

Models:  AIK14X, AIK16X, AIK24Y, AIK26Y,

 

AIF4X, AIF6Y, AIF8X, AIF10X,

 

AIG4, AIG6

Summary of Contents for AIF10X

Page 1: ...ll applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to pre...

Page 2: ...ber vibration isolation grommets to prevent the transmission of sound through the structure Be careful not to over tighten Also care should be taken not to strip the plastic housing Screws are self ta...

Page 3: ...e or a screw clamp to create as air tight a seal as possible Repeat this step for the other room level grill housing Figure 7 www airkinglimited com A210952017 Rev B 8 12 3 of 12 NOTE Units that inclu...

Page 4: ...IAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN 1 Remove the screws securing the terminal box cover plate located on the side of the motor Figure 9 2 Ru...

Page 5: ...E PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACME...

Page 6: ...7 1 Y Transition AIK24Y 5S7635008 1 Y Transition AIK26Y 5S7635010 8 12 Screw 5S7699022 9 2 Collar Damper Assembly AIK24Y 5S7635039 2 Collar Damper Assembly AIK26Y 5S7635015 10 2 Grill AIK24Y 5S763501...

Page 7: ...t la construction relative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combusti...

Page 8: ...ge soit facilement accessible Figure 2 www airkinglimited com A210952017 Rev B 8 12 8 of 12 REMARQUE Le support est muni de passe c bles isol s en caoutchouc pour la vibration afin d emp cher la trans...

Page 9: ...pi ce et l autre extr mit l embranchement en Y Fixez les deux extr mit s en place en utilisant du ruban ou un serre joint afin de cr er un joint aussi tanche que possible R p tez cette tape pour le c...

Page 10: ...DES D INSTALLATION DE C BLAGE LECTRIQUE RECOURREZ AUX SERVICES D UN LECTRICIEN QUALIFI 1 Retirez les vis de la plaque du couvercle de la bo te de raccordement situ e sur le c t du moteur Figure 9 2 Pa...

Page 11: ...IER ET DANS AUCUN CAS AIR KING N ASSUME AUCUNE RESPONSABILIT EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUS...

Page 12: ...Y AIK26Y 5S7635010 8 12 Vis 5S7699022 9 1 Assemblage collet clapet AIK24Y 5S7635039 1 Assemblage collet clapet AIK26Y 5S7635015 10 1 Grille AIK24Y 5S7635016 1 Grille AIK26Y 5S7635017 11 8 Ressorts pou...