background image

INSTALLATION INSTRUCTIONS
CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT SERVICE 

PANEL BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1.  When selecting fan mounting location, the following criteria should be 

considered:

a) 

Mounting to minimize noise generated by fan operation:

 

Mounting the fan as far as possible from the intake point will 

minimize fan operating noise from being transmitted back 

through the duct work. If the fan is to be used as a booster for 

moving the air between two rooms, a central point along the duct 

may be optimal. Insulated flexible type duct work (recommended 

for all bathroom exhaust applications) will result in much quieter 

operation. It is recommended that a minimum 8’ of insulated 

flexible ducting be used between any exhaust grill and fan for low 

noise level.

b) 

Service accessibility:

 Fan location should allow sufficient 

access for service. 

SECTION 2

Installing the Fan

1.  Using the 1" wood screws provided, attach the fan mounting bracket 

to a support beam at the selected location 

(Figure 1).

NOTE:

 Fan mounting can be at any point along the duct and in any angle, 

however, vertical mounting is recommended to reduce condensation buildup 

in the fan. If a horizontal installation is necessary and condensation buildup 

may pose a problem, wrap insulation around the fan to minimize buildup.

2.  Attach fan to the mounting bracket with the three 7/16" sheet metal 

screws provided, making sure the wiring box is positioned for easy 

access 

(Figure 2).

www.airkinglimited.com

A210952017 Rev. B 8-12

2 of 12

NOTE:

 Bracket is provided with rubber vibration isolation grommets to 

prevent the transmission of sound through the structure. Be careful not 

to over tighten. Also, care should be taken not to strip the plastic housing. 

Screws are self tapping and do not require pilot holes. Pilot holes no larger 

than 1/16" can be used to ease the installation however.

SECTION 3

Installing Supply/Exhaust Grill

1.  Select the grill mounting point within the area to be ventilated that 

does not interfere with a ceiling joist. To ease installation, locations of 

framing beams within the walls or joists supporting the ceiling should 

be considered. Collar/damper is provided with a perforated hanging 

strap for attachment directly to a beam or joist. Allow sufficient space 

between the collar/damper and the beam to attach the duct work. 

If the location of the grill does not allow direct attachment, a cross-

member mounted to the framing should be used.

2.  Bend the mounting straps attached to the  collar outward so they are 

straight across 

(Figure 3).

SECTION 4

New Construction

1.   Install the collar/damper in the selected location using the provided 

1" wood screws through the mounting strap. The mounting height is 

determined by the thickness of the final wall/ceiling material. Ensure 

that the edge of the collar/damper will be flush with the finished wall/

ceiling material

 (Figure 4).

2.  Once the wall/ceiling material is in place, install the grill into the collar 

by pushing it firmly inward towards the collar until it fits flush against 

the wall/ceiling material 

(Figure 5).

Figure 1

Vertical Mounting

Stud

Horizontal Mounting

Bracket

Bracket

or

Joist

Fan

Stud

Screws

Bracket

Figure 2

Mounting 

Strap

Mounting 

Strap

Collar/Damper

Figure 3

Joist/Stud

Screws

Collar/Damper

Collar/Damper

Joist/Stud

Wall/Ceiling Material

Figure 4

Summary of Contents for AIF10X

Page 1: ...ll applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to pre...

Page 2: ...ber vibration isolation grommets to prevent the transmission of sound through the structure Be careful not to over tighten Also care should be taken not to strip the plastic housing Screws are self ta...

Page 3: ...e or a screw clamp to create as air tight a seal as possible Repeat this step for the other room level grill housing Figure 7 www airkinglimited com A210952017 Rev B 8 12 3 of 12 NOTE Units that inclu...

Page 4: ...IAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN 1 Remove the screws securing the terminal box cover plate located on the side of the motor Figure 9 2 Ru...

Page 5: ...E PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACME...

Page 6: ...7 1 Y Transition AIK24Y 5S7635008 1 Y Transition AIK26Y 5S7635010 8 12 Screw 5S7699022 9 2 Collar Damper Assembly AIK24Y 5S7635039 2 Collar Damper Assembly AIK26Y 5S7635015 10 2 Grill AIK24Y 5S763501...

Page 7: ...t la construction relative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combusti...

Page 8: ...ge soit facilement accessible Figure 2 www airkinglimited com A210952017 Rev B 8 12 8 of 12 REMARQUE Le support est muni de passe c bles isol s en caoutchouc pour la vibration afin d emp cher la trans...

Page 9: ...pi ce et l autre extr mit l embranchement en Y Fixez les deux extr mit s en place en utilisant du ruban ou un serre joint afin de cr er un joint aussi tanche que possible R p tez cette tape pour le c...

Page 10: ...DES D INSTALLATION DE C BLAGE LECTRIQUE RECOURREZ AUX SERVICES D UN LECTRICIEN QUALIFI 1 Retirez les vis de la plaque du couvercle de la bo te de raccordement situ e sur le c t du moteur Figure 9 2 Pa...

Page 11: ...IER ET DANS AUCUN CAS AIR KING N ASSUME AUCUNE RESPONSABILIT EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUS...

Page 12: ...Y AIK26Y 5S7635010 8 12 Vis 5S7699022 9 1 Assemblage collet clapet AIK24Y 5S7635039 1 Assemblage collet clapet AIK26Y 5S7635015 10 1 Grille AIK24Y 5S7635016 1 Grille AIK26Y 5S7635017 11 8 Ressorts pou...

Reviews: