IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

SAVE THESE INSTRUCTIONS

www.airkinglimited.com

6727930 Rev. E 11-18

1 of 12

Exhaust Fan

AK150D, AK150DH, 

AK150DG, AK150DG

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN 

THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL 

INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should 

always be followed to reduce the risk of fire, electric shock and 

injury to person, including the following:

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer.If you have 

questions, contact the manufacturer.

b)  Before servicing or cleaning the unit, switch power off at service 

panel and lock the service disconnecting means to prevent power 

from being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-related construction.

b)  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 

back drafting. Follow the heating equipment manufacturer’s guideline 

and safety standards such as those published by the National Fire 

Protection Association (NFPA) and the American Society for Heating, 

Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local 

code authorities.

c)  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. 

DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE 

MATERIALS AND VAPORS.

d)  Ducted fans must always be vented to the outdoors.
e)  If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application and be connected to a GFCI (Ground 

Fault Circuit Interrupter) – protected branch circuit. 

f)  This unit must be grounded.
g)  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

h)  Read all instructions before installing or using exhaust fan.
i)  Suitable for use with electronic speed control device.

WARNING:

 DO NOT USE IN KITCHENS.

WARNING: 

THE DUCTING FROM THIS FAN TO THE 

OUTSIDE OF THE BUILDING HAS A STRONG EFFECT 

ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE 

THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR 

BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH 

SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND 

THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD 

GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT 

ACHIEVE THEIR RATED AIRFLOW.

Summary of Contents for AK150D

Page 1: ...elated construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment ma...

Page 2: ...e previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 1 www airkinglimited com 6727930 Rev E 11 18 2 of 12 SECTION 4 Ducting NOTE 6 OR L...

Page 3: ...he switch will change from normal to high speed A manual override switch not included can be used to provide a manual fan Off function Figure 10 Motion and Humidity Sensing Models 6 For two speed fans...

Page 4: ...the setting while the sensor is still flashing from Step 1a press the button the number of times that corresponds with the amount of time you desire for instance 3 times sets the delay to 5 minutes se...

Page 5: ...R FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF AN...

Page 6: ...odel AK150D Qty Description Replacement Part 7 1 Grill 5S1202048 8 1 Wire Compartment Assembly 5S1202636 Specific to Model AK150DG Qty Description Replacement Part 9 1 Wire Compartment Assembly 5S1202...

Page 7: ...ion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les nor...

Page 8: ...18 8 of 12 SECTION 4 Conduits NOTE UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE MEILLEURE PERFORMANCE ATTENTION TOUS LES CONDUITS DOIVENT TRE CONFORMES AUX CODES DU B TIMENT LOCAUX E...

Page 9: ...uellement le ventilateur Figure 10 Mod les avec d tection de mouvement et d humidit 6 Pour les ventilateurs deux vitesses raccord s pour une ventilation continue connectez le fil blanc du ventilateur...

Page 10: ...10 minutes 9 fois 20 minutes 1b Pour ajuster le r glage tandis que le capteur continue de clignoter partir de l tape 1a appuyez sur le bouton le nombre de fois qui correspond la quantit de temps que...

Page 11: ...ER ET DANS AUCUN CAS AIR KING N ASSUME AUCUNE RESPONSABILIT EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUSI...

Page 12: ...ement 7 1 Grille 5S1202048 8 1 Assembl e du compartiment du fil 5S1202636 Particularit s des mod le AK150DG Qt Description de pi ce de remplacement 9 1 Assembl e du compartiment du fil 5S1202639 12 1...

Reviews: