INSTALLATION INSTRUCTIONS
CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE 

STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1.  Unpack fan from the carton and confirm that all pieces are present. In addition to the 

exhaust fan you should have:

 

 

1 - Grill with Light Lens

 

 

4 - Mounting Rails

 

1 - Instruction/Safety Sheet  

2.  Remove the two hex nuts holding the light reflector in place. Keep the reflector and nuts 

in the carton until needed so they do not get damaged or lost 

(Figure 1).

 

3.  Remove the fan’s venturi assembly, which is secured in place with one screw through the 

venturi 

(Figure 2).

 Keep the venturi assembly and the grill in the carton until needed so 

they do not get damaged or lost. 

WARNING:

 DO NOT INSTALL OVER A TUB OR MOUNT IN A SHOWER STALL 

ENCLOSURE.

4.  Choose the location for your unit. To ensure 

the best air and sound performance, it is 
recommended that the length of ducting and 
the number of elbows be kept to a minimum, 
and that insulated hard ducting be used. 
Larger duct sizes will reduce noise and airflow 
restrictions. This fan will require at least 7" 
of clearance in the ceiling, and will mount 
through drywall up to 3/4" thick. The fan 
mounts between 16" on center joists using the 
4 provided mounting rails.

5.  Remove the electrical knockouts using a 

straight-blade screw driver 

(Figure 3)

.

SECTION 2

New Construction

1.  Install the rails on the housing and position the housing next to the joist. Line up housing 

so it will be flush with the finished ceiling. Secure the ends of the rails with screws or 
nails (not included) to the joists and slide housing into final position 

(Figure 4).

www.airkinglimited.com

210575917 Rev. C 1-13

2 of 8

SECTION 3

Existing Construction

1.  Set housing in position between the joist and trace an outline onto the ceiling material 

(Figure 5)

. Set housing aside and cut opening, being careful not to cut or damage any 

electrical or other hidden utilities. Install the rails on the housing and position the housing 
in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the 
rails to the joists with screws or nails (not provided) to ensure proper installation 

(Figure 4).

SECTION 4

Ducting

CAUTION: 

ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL 

BUILDING CODES.

1.  Remove any tape that might be holding the damper in place. Connect the ducting to the 

fan’s duct collar 

(Figure 6)

 and secure in place using tape or screw clamp. Always duct 

the fan to the outside through a wall or roof cap.

SECTION 5

Wiring

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE 

STARTING INSTALLATION.

WARNING:

 THIS UNIT MUST BE WIRED ON A SEPARATE 15 AMP CIRCUIT.

WARNING:

 

USE APPROPRIATELY SIZED COPPER CONDUCTORS ONLY RATED 

FOR AT LEAST 75°C.

Figure 1

Nuts

Figure 2

Screw

Figure 3

Figure 4

Housing

Joist

Mounting Rails

Figure 5

Figure 6

Summary of Contents for AK55L

Page 1: ...with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment...

Page 2: ...driver Figure 3 SECTION 2 New Construction 1 Install the rails on the housing and position the housing next to the joist Line up housing so it will be flush with the finished ceiling Secure the ends...

Page 3: ...methods for all connections SECTION 6 Completing the Installation 1 Reinstall the fan s venturi by holding it at approximately a 45 degree angle hook the two tabs on the venturi into the slots on the...

Page 4: ...blade is hitting housing of unit 3b Call your dealer for service Figure 13 Connector Bar Tabs LIMITED WARRANTY WHAT THIS WARRANTY COVERS This product is warranted against defects in workmanship and o...

Page 5: ...elative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir u...

Page 6: ...olives l aide des quatre 4 traverses de montage incluses 5 Enlever l alv ole d fon able l aide d un tournevis plat Figure 3 SECTION 2 Nouvelle Construction 1 Installer les traverses sur le ch ssis et...

Page 7: ...on de l installation 1 R installer le venturi du ventilateur en le tenant un angle d environ 45 degr s accrocher les deux onglets sur le venturi dans les fentes sur le cabinet et fixer en place en ser...

Page 8: ...xt rieur 3 Le ventilateur fonctionne de mani re plus 3a Le moteur est l che 3a Couper l alimentation l unit Retirer la grille et v rifier que toutes les bruyante que la normale vis sont compl tement s...