background image

4.  Reinstall the lens into the grill 

(Figure 11). 

5.  Restore power and test your installation.

SECTION 7

Use and Care

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE 

PANEL BEFORE SERVICING THE UNIT.

CAUTION:

 ALLOW BULB TO COOL BEFORE REPLACING.

Changing the Lamp

Remove the light lens by squeezing at the tabs and pulling down 

(Figure 

12).

 Remove lamp by gently twisting the lamp base counterclockwise while 

applying outward pressure. Installation is the reverse of removal. Replace 

with Air King model 26SBL or a compatible GU24 26 watt self ballasted lamp.

www.airkinglimited.com

A210572219 Rev. D 12-12

4 of 12

Cleaning the Grill

Remove grill and use a mild detergent, such as dishwashing liquid, and 

dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING 

POWDERS. Completely dry grill before reinstalling. Refer to instructions in 

Section 6

 

Finishing the Installation

, to reinstall grill.

Cleaning the Fan Assembly

Unplug the motor cord from receptacle. Wipe all parts with a dry cloth or 

gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER. 

Plug the motor cord back in and restore power.

Troubleshooting Guide

    Trouble 

 

Probable Cause 

 

Suggested Remedy

  1.  Fan does not operate when the switch is on. 

1a.  A fuse may be blown or a circuit tripped. 

1a.  Replace fuse or reset circuit breaker.

     

1b.  Connector plug from motor is not plugged in.  1b.  Turn off power to unit. Remove Grill and plug motor into receptacle

     

 

 

 

in housing. Restore power to unit.

     

1c.  Wiring is not connected properly. 

1c.  Turn off power to unit. Check that all wires are connected.

     

1d 

Motor has stopped operating. 

1d.  Replace motor.

  2.  Fan is operating, but air moves slower than normal. 

2. 

Obstruction in the exhaust ducting. 

2. 

Check for any obstructions in the ducting. The most common are bird

     

 

 

 

nests in the roof cap or wall cap where the fan exhausts to the outside.

  3.  Fan is operating louder than normal 

3a.  Motor is loose. 

3a.  Turn off power to unit. Remove grill and check that all screws are fully

     

 

 

 

tightened. Restore power to unit.

     

3b.  Fan blade is hitting housing of unit. 

3b.  Call your dealer for service.

Tabs

Figure 12

Figure 11

Summary of Contents for BFQF50

Page 1: ...y qualified person s in accordance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Associati...

Page 2: ... bottom of the fan will be flush with the finished ceiling Nail or screw the bracket in place securely Figure 3 2 Snap the fan body into the bracket Figure 4 The fan can be snapped into position with the duct collar facing to the left or the right depending which is most convenient www airkinglimited com A210572219 Rev D 12 12 2 of 12 SECTION 3 Existing Construction 1 Position housing against the ...

Page 3: ...to both the black wire from the fan s light receptacle and the black wire from the fan s exhaust receptacle Connect the ground wire from the house to the green wire from the fan s receptacle Figure 8 Use approved methods for all connections www airkinglimited com A210572219 Rev D 12 12 3 of 12 SECTION 6 Completing the Installation 1 Reinstall the fan s wire compartment cover Rotate the blower whee...

Page 4: ...om receptacle Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER Plug the motor cord back in and restore power Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1 Fan does not operate when the switch is on 1a A fuse may be blown or a circuit tripped 1a Replace fuse or reset circuit breaker 1b Connector plug from motor is not plugged in 1b T...

Page 5: ... THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURC...

Page 6: ... Clip 5S2205025 6 1 Wire Cover 5S2205040 7 1 Blower Wheel 5S2299004 8 1 Motor BFQF50 5S2299011 Motor BFQF70 5S2299012 9 1 Clip 5S2205029 10 1 Motor Bracket 5S2299003 11 1 Grill Assembly 5S9205030 12 1 Light Lens 5S2205031 13 1 26 Watt Lamp 5S9999010 www airkinglimited com A210572219 Rev D 12 12 6 of 12 REPLACEMENT PARTS DIAGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Page 7: ...es codes et normes applicables incluant la construction relative aux incendies b De l air en quantité suffisante est requis pour la bonne combustion et l évacuation de gaz par le conduit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la Na...

Page 8: ...eur soit à effleurement avec le plafond fini Clouer ou visser solidement le support en place Figure 3 www airkinglimited com A210572219 Rev D 12 12 8 of 12 2 Fixer par pression le bâti du ventilateur dans le support Figure 4 Le ventilateur peut être fixé par pression en position avec le collet de conduit faisant face à gauche ou à droite en fonction de quelle direction est la plus pratique SECTION...

Page 9: ...du ventilateur raccorder un fil blanc provenant de la maison aux deux fils blancs du réceptacle de la lumière et le fil blanc du réceptacle du ventilateur d évacuation Raccorder le fil noir provenant du commutateur mural aux deux fils noir du réceptacle de la lumière et au fil noir du réceptacle du ventilateur d évacuation Raccorder le fil de mise à la terre de la maison au fil vert du réceptacle ...

Page 10: ...ètement la grille avant de la réinstaller Pour réinstaller la grille vous référer à la Section 6 Complétion de l installation Nettoyage de l assemblage du ventilateur Débrancher le cordon du moteur de son réceptacle Nettoyer toutes les pièces avec un chiffon sec ou passer délicatement l aspirateur dans le ventilateur NE JAMAIS IMMERGER DES PIÈCES ÉLECTRIQUES DANS L EAU Rebrancher le cordon et reme...

Page 11: ... ET DANS AUCUN CAS AIR KING N ASSUME AUCUNE RESPONSABILITÉ EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA RÉPARATION DE TOUS FUSIBLES DISJONCTEURS OU RÉCEPTACLES DE MAISON MALGRÉ N IMPORTE QUOI À L EFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILITÉ D AIR KING SOUS UNE GARANTIE EXPRESSE OU TACITE NE DÉPASSERA LE PRIX D ACHAT DU PRO...

Page 12: ...99054 3 1 Réceptacle du Moteur 5S2205004 4 1 Réceptacle de la Lumière 5S1201012 5 2 Clip 5S2205025 9 1 Couvercle des câbles 5S2205040 7 1 Roue de la Soufflante 5S2299004 8 1 Moteur BFQF50 5S2299011 Moteur BFQF70 5S2299012 9 1 Clip 5S2205029 10 1 Support du Moteur 5S2299003 11 1 Assemblée de grille 5S9205030 12 1 Lentille d éclairage 5S2205031 13 1 Lampe de 26 watts 5S9999010 1 2 3 4 5 6 7 8 9 10 1...

Reviews: