SPECIFICATIONS
EXHAUST FANS
DRLC
70 CFM/4.0 SONES @ 0.10" WG. -HVI CERTIFIED
120 Volts, 1.6 amps, 60 hz.
•
Grill
DRLC702
- Nickel Finish: 13
1/2
" diameter.
DRLC703
- White Finish: 13
1/2
" diameter.
DRLC709
- Bright Brass Finish: 13
1/2
" diameter.
• Light Lens
Ribbed frosted glass light lens.
• Light Housing
Heavy gauge cold rolled steel c/w baked enamel finish; locks
in place on the grill via two integral tabs.
• Blower Wheel
One piece polymeric wheel, 4
1/2
" diameter, 1" wide, with 10 fins.
• Motor
Single coil plug-in, two pole motor, life time lubrication, thermally
protected. Rated 120 volts, 60 hz., 1.6 amps.
• Fan Housing
23 ga. Galvanized metal housing, dimensions 8" x 6
7/8
" x 5
1/2
",
double metal thickness mounting tabs.
• Duct Collar
Plastic collar for 4" duct connection, comes complete with built
in non-metallic back draft damper for quiet operation.
• Lighting
Single 100 watt maximum light capacity
(bulb not included).
CUL/HVI
Canada:
110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
U.S.:
820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
New 4-05
Specifications subject to change without notice.
• Unit Mounting
Rated Type IC for ceilings insulated to R-40. Designed to mount
in ceilings with at least 6" of clearance. The unit will mounts
directly to the joist with a rough in opening of 8
3/16
" x 7
1/16
". The
housing will mount through drywall thickness up to
3/4
".
• Ventilating Area
For bathrooms up to 70 sq. ft. for other rooms up to 85 sq. ft.
• Single Pack Shipping Info
Box Dim: 11
1/2
" x 13
1/4
" x 9
1/2
"
DRLC702
- UPC: 0-8316227421-2
DRLC703
- UPC: 0-8316227411-3
DRLC709
- UPC: 0-8316227431-1
C
US
Air-King exhaust fans are tested by the Air Movement and Control Association (AMCA) in accordance with HVI test standard 916, (Air Flow Test Standard) and HVI test standard
915 (Procedure For Loudness Rating Of Residential Fan Products). The Performance results are certified and verified by the Home Ventilating Institute (HVI).
HVI PERFORMANCE
Static Pressure (inches of w.g.)
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
0.4
CFM
77
74
71
68
65
61
57
52
45
RPM
2300
2400
2450
2500
2550
2600
2650
2710
2840
WATTS
65
66
65
64
64
63
61
60
58
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY
DATE
FAN
MODEL
CFM
IN
RPM
WATTS
AMPS
SONES
QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER
W.C.
& REMARKS
Acceptable for use over tub or shower when
installed in a GFCI protected branch circuit.