background image

INSTALLATION INSTRUCTIONS
CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL 

BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1.  Unpack fan from the carton and confirm that all pieces are present. In addition 

to the exhaust fan you should have:

 

 

1 - Grill

 

 

1 - Damper Assembly (attached)

 

 

4 - Mounting Rails

 

 

1 - Mounting Flange

 

 

1 - Instruction/Safety Sheet   

2.  Choose the location for your fan. To ensure the best air and sound 

performance, it is recommended that the length of ducting and the number 
of elbows be kept to a minimum, and that insulated hard ducting be used. 
Larger duct sizes will reduce noise and airflow 
restrictions. This fan will require at least 10

"

 of 

clearance in the ceiling or wall, and will mount 
through drywall up to 3/4

"

 thick.

3.  Select the most convenient electrical knockout 

and remove using a straight-blade screw driver 

(Figure 1).

SECTION 2

New Construction

1.  Install the rails into the mounting channel on the housing. Center the mounting 

channel in the slots on the housing, then from inside the housing tighten 
the mounting channel nuts so the channel is securely in place. Position the 
housing next to the joist. Line up housing so that it will be flush with the 
finished ceiling. Secure the ends of the rails with screws or nails (not included) 
to the joists and slide the housing into the final position 

(Figure 2).

SECTION 3

Existing Construction

1.  Set housing in position between the joist and trace an outline onto the ceiling 

material 

(Figure 3).

 Set housing aside and cut opening, being careful not to cut or 

damage any electrical or other hidden utilities. Install the rails into the mounting 
channel on the housing. Center the mounting channel in the slots on the housing, 
then from inside the housing tighten the mounting channel nuts so the channel is 
securely in place. Position the housing in the previously cut hole so that it is flush 
with the finished ceiling. Secure the ends of the rails to the joists 

(Figure 2).

www.airkinglimited.com

6728039 Rev. B 3-13

2 of 12

SECTION 4

Ducting

CAUTION:

 

ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL 

BUILDING CODES.

1.  Connect the ducting to the fan’s duct collar 

(Figure 4).

 Secure in place using tape 

or screw clamp. Always duct the fan to the outside through a wall or roof cap.

SECTION 5

Wiring

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL 

BEFORE STARTING INSTALLATION.

CAUTION:

 ALL ELECTRICAL CONNECTIONS MUST BE MADE IN 

ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL 

CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL 

WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

NOTE:

 This unit includes a side access panel for wiring that does not require the 

removal of the fan’s blower assembly. If you choose to wire the unit from the inside, 

you will need to remove the blower assembly and internal wiring compartment. 

Both methods are equally effective.

1a.  External Wire Compartment: Remove the wire compartment cover screw and 

place cover in a secure place 

(Figure 5).

1b.  Internal Wire Compartment: Using a 7/16

"

 socket, remove the two hex nuts 

holding the blower assembly in place. Lift up on the assembly and slide it out 

of the tabs on the housing 

(Figure 6).

 Remove the wire compartment cover 

screw (or screws) and place the cover in a secure place 

(Figure 7).

Figure 1

Ducting

Duct 

Collar

Figure 4

Figure 5

Screw

Wire 

Compartment 

Cover

Housing

Joist

Mounting Rails

Figure 2

Figure 3

Joist

Summary of Contents for ES130D

Page 1: ...by qualified person s in accordance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the fl...

Page 2: ...the rails into the mounting channel on the housing Center the mounting channel in the slots on the housing then from inside the housing tighten the mounting channel nuts so the channel is securely in...

Page 3: ...res will be present NOTE Unit must be grounded according to all local and national codes Humidity Sensing Models 3 For two speed fans wired for continuous ventilation connect the White wire of the fan...

Page 4: ...nds 2 times 2 5 minutes 6 times 12 5 minutes 3 times 5 minutes 7 times 15 minutes 4 times 7 5 minutes 8 times 17 5 minutes 5 times 10 minutes 9 times 20 minutes 1b To adjust the setting while the sens...

Page 5: ...S OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO...

Page 6: ...7 1 Grill 5S1202048 8 1 Wire Compartment Assembly ES80D 5S1239004 1 Wire Compartment Assembly ES130D 5S1239005 Specific to Models ES80D ES130D ES130D2 Qty Description Replacement Part 7 1 Grill 5S1202...

Page 7: ...avec tous les codes et normes applicables incluant la construction relative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chem...

Page 8: ...sur le bo tier Centrez le canal de montage dans les fentes sur le bo tier puis de l int rieur du bo tier serrez les crous de montage de sorte que le canal soit bien en place Positionnez le bo tier dan...

Page 9: ...x Mod les avec d tection d humidit 3 Pour les ventilateurs deux vitesses c bl s pour la ventilation continue connectez le fil blanc du ventilateur au fil neutre blanc de la source d alimentation Conne...

Page 10: ...apr s que la salle soit vacu e Localisez le d tecteur de mouvement sur le gril du ventilateur et appuyez sur le bouton 2 fois Le LED sur le capteur clignotera alors le nombre de fois pour indiquer le...

Page 11: ...MAISON MALGR N IMPORTE QUOI L EFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILIT D AIR KING SOUS UNE GARANTIE EXPRESSE OU TACITE NE D PASSERA LE PRIX D ACHAT DU PRODUIT ET UNE TELLE RESPONSABILIT SE TERM...

Page 12: ...Assembl e du compartiment du fil ES80D 5S1239004 1 Assembl e du compartiment du fil ES130D 5S1239005 Particularit s des mod les ES80D ES130D ES130D2 de pi ce Qt Description de remplacement 7 1 Grille...