    Trouble 

 

Probable Cause 

 

Suggested Remedy

  1.  Fan does not operate when the switch is on. 

1a.  A fuse may be blown or a circuit tripped. 

1a.  Replace fuse or reset circuit breaker.

     

1b.  Connector plug from motor is not plugged in.  1b.  Turn off power to unit. Remove Grill and plug motor into receptacle

     

 

 

 

in housing. Restore power to unit.

     

1c.  Wiring is not connected properly. 

1c.  Turn off power to unit. Check that all wires are connected.

     

1d 

Motor has stopped operating. 

1d.  Replace motor.

  2.  Fan is operating, but air moves slower than normal. 

2. 

Obstruction in the exhaust ducting. 

2. 

Check for any obstructions in the ducting. The most common are bird

     

 

 

 

nests in the roof cap or wall cap where the fan exhausts to the outside.

  3.  Fan is operating louder than normal 

3a.  Motor is loose. 

3a.  Turn off power to unit. Remove grill and check that all screws are fully

     

 

 

 

tightened. Restore power to unit.

     

3b.  Fan blade is hitting housing of unit. 

3b.  Call your dealer for service.

Installer: 

 

Installation Date: 

Place of Purchase: 

 

Model Number: 

LIMITED WARRANTY

WHAT THIS WARRANTY COVERS:

 This product is warranted against defects in workmanship and/or materials. 

HOW LONG THIS WARRANTY LASTS:

 This warranty extends only to the original purchaser of the product and lasts for five (5) years from the date of original purchase 

or until the original purchaser of the product sells or transfers the product, whichever first occurs. 

WHAT AIR KING WILL DO:

 During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole 

product with the same or comparable model. 

WHAT THIS WARRANTY DOES NOT COVER:

 This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, 

shipping damage, abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or 

replacement. Air King will pay return shipping charges from Air King following warranty repairs or replacement 

ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR 

FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST 

OCCURS AND IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES 

FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO 

THE CONTRARY, IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT 

AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.

Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these 

exclusions or limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to 

province. Proof of purchase is required before a warranty claim will be accepted. 

CUSTOMER SERVICE:

Toll-Free (800) 465-7300

Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday through 

Friday, 8am-4pm Eastern. Please have your model number available, as well as the type and style (located on the label inside of your product). 

Please do not return product to place of purchase.

www.airkinglimited.com

PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS 

AND MOST HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL 

BEFORE SERVICING THE UNIT.

1.  To set the desired humidity level of the room, remove the grill and locate the 

dehumidistat dial located on the wire compartment cover. 

2.  Set the dial to the relative humidity you want the fan to maintain usually 

between 50 & 80%. Moist climates will require higher settings than dry 

climates. When the humidity level of the room is below this setting the fan will 

remain off. When the humidity level rises about this setting the fan will turn on 

and run until the humidity level falls below this setting. 

3.  Reinstall the grill and restore power. 

SECTION 9

Use and Care

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL 

BEFORE SERVICING THE UNIT.

1. 

Cleaning the Grill:

 Remove grill and use a mild detergent, such as 

dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS 

OR SCOURING POWDERS. Completely dry grill before reinstalling. Refer to 

instructions in 

Section 6

 

Finishing the Installation

, to reinstall grill.

2. 

Cleaning the Fan Assembly:

 Wipe all parts with a dry cloth or gently vacuum 

the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER.

Summary of Contents for ES130D

Page 1: ...by qualified person s in accordance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the fl...

Page 2: ...the rails into the mounting channel on the housing Center the mounting channel in the slots on the housing then from inside the housing tighten the mounting channel nuts so the channel is securely in...

Page 3: ...res will be present NOTE Unit must be grounded according to all local and national codes Humidity Sensing Models 3 For two speed fans wired for continuous ventilation connect the White wire of the fan...

Page 4: ...nds 2 times 2 5 minutes 6 times 12 5 minutes 3 times 5 minutes 7 times 15 minutes 4 times 7 5 minutes 8 times 17 5 minutes 5 times 10 minutes 9 times 20 minutes 1b To adjust the setting while the sens...

Page 5: ...S OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO...

Page 6: ...7 1 Grill 5S1202048 8 1 Wire Compartment Assembly ES80D 5S1239004 1 Wire Compartment Assembly ES130D 5S1239005 Specific to Models ES80D ES130D ES130D2 Qty Description Replacement Part 7 1 Grill 5S1202...

Page 7: ...avec tous les codes et normes applicables incluant la construction relative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chem...

Page 8: ...sur le bo tier Centrez le canal de montage dans les fentes sur le bo tier puis de l int rieur du bo tier serrez les crous de montage de sorte que le canal soit bien en place Positionnez le bo tier dan...

Page 9: ...x Mod les avec d tection d humidit 3 Pour les ventilateurs deux vitesses c bl s pour la ventilation continue connectez le fil blanc du ventilateur au fil neutre blanc de la source d alimentation Conne...

Page 10: ...apr s que la salle soit vacu e Localisez le d tecteur de mouvement sur le gril du ventilateur et appuyez sur le bouton 2 fois Le LED sur le capteur clignotera alors le nombre de fois pour indiquer le...

Page 11: ...MAISON MALGR N IMPORTE QUOI L EFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILIT D AIR KING SOUS UNE GARANTIE EXPRESSE OU TACITE NE D PASSERA LE PRIX D ACHAT DU PRODUIT ET UNE TELLE RESPONSABILIT SE TERM...

Page 12: ...Assembl e du compartiment du fil ES80D 5S1239004 1 Assembl e du compartiment du fil ES130D 5S1239005 Particularit s des mod les ES80D ES130D ES130D2 de pi ce Qt Description de remplacement 7 1 Grille...

Reviews: