ceiling mounting flange with the screw holes on the inside of the housing 
and press flange in place so it is tight against the ceiling. Reinstall ceiling 
flange mounting screws inside the housing 

(Figure 11)

.

NOTE:

 If the housing is mounted to far or not far enough into the ceiling for 

the flange to make a solid connection, loosen the mounting channel and 

adjust the housing up or down on the rails. Once in place, fully tighten the 

mounting channel nuts.

4.  Install the grill by squeezing the two ends of the springs together and 

installing them up into the slots on the fan’s housing. Push the grill up 

into position 

(Figure 12).

5.  Restore power and test your installation.

www.airkinglimited.com

6728020 Rev. B 8-12

4 of 12

SECTION 7

Setting the Humidistat

This fan is equipped with a humidity sensor that automatically turns the 

fan on (or to high speed on dual speed models) when humidity is above set 

point and off (or back to low speed on dual speed models) when humidity 

is at or below set point. If the fan is operating too long or not enough, first 

check to see the humidity sensor set point. In cases where the ambient 

humidity level of the room rises higher than the preset level, the fan will 

turn on even if the room is not occupied. This helps prevent conditions that 

lead to mold growth.

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT SERVICE 

PANEL BEFORE SERVICING THE UNIT.

1.  To set the desired humidity level of the room, remove the grill and 

locate the dehumidistat dial located on the wire compartment cover. 

2.  Set the dial to the relative humidity you want the fan to maintain 

usually between 50 & 80%. Moist climates will require higher settings 

than dry climates. When the humidity level of the room is below this 

setting the fan will remain off. When the humidity level rises about this 

setting the fan will turn on and run until the humidity level falls below 

this setting. 

3.  Reinstall the grill and restore power. 

SECTION 8

Use and Care

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE 

PANEL BEFORE SERVICING THE UNIT.

1. 

Cleaning the Grill:

 Remove grill and use a mild detergent, such 

as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY 

ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill 

before reinstalling. Refer to instructions in 

Section 5

 

Finishing the 

Installation

, to reinstall grill.

2. 

Cleaning the Fan Assembly:

 Wipe all parts with a dry cloth or gently 

vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER.

Figure 12

Figure 11

Screws

Ceiling 

Mounting 

Flange

Screw Holes

Summary of Contents for ES130DH

Page 1: ...must be done by qualified person s in accordance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protec...

Page 2: ...eiling material Figure 3 Set housing aside and cut opening being careful not to cut or damage any electrical or other hidden utilities Install the rails into the mounting channel on the housing Center the mounting channel in the slots on the housing then from inside the housing tighten the mounting channel nuts so the channel is securely in place Position the housing in the previously cut hole so ...

Page 3: ...power source Connect the ground wire from the house www airkinglimited com 6728020 Rev B 8 12 3 of 12 to the green wire from the fan housing Connect the Black wire of the fan to the Black wire Hot from the power source The fan will operate on low speed continuously and boost to high upon a rise in humidity A manual override switch not included can be used to provide a manual fan Off function Figur...

Page 4: ...ses higher than the preset level the fan will turn on even if the room is not occupied This helps prevent conditions that lead to mold growth CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT 1 To set the desired humidity level of the room remove the grill and locate the dehumidistat dial located on the wire compartment cover 2 Set the dial to the relative humidity...

Page 5: ... unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST ONE YEAR FROM THE DATE OF ORIGINAL ...

Page 6: ...sher 5S1112012 12 2 Grommets 5S1202032 Qty Description Replacement Part 13 1 10 Ground Screw 5S1999002 14 1 14 ga Ground Wire 5S1999003 15 1 Wire Compartment Assembly ES80S ES130S 5S1299801 16 1 Wire Harness ES80S 5S2239002 Wire Harness ES130S 5S2239003 17 1 Wire Compartment Assembly ES80D ES130D 5S1299803 18 2 Wire Cover Screw 6 5S1999010 19 1 Knob 5S1299802 20 2 Flange Screw 5S1202049 21 1 Ceili...

Page 7: ... conformité avec tous les codes et normes applicables incluant la construction relative aux incendies b De l air en quantité suffisante est requis pour la bonne combustion et l évacuation de gaz par le conduit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que ce...

Page 8: ...tention de ne pas couper ou endommager les installations électriques ou d autres utilités masquées Installez les rails dans le canal de montage sur le boîtier Centrez le canal de montage dans les fentes sur le boîtier puis de l intérieur du boîtier serrez les écrous de montage de sorte que le canal soit bien en place Positionnez le boîtier dans le trou préalablement découpé de sorte qu il soit ali...

Page 9: ...on continue Pour les ventilateurs à deux vitesses câblés pour la ventilation continue connectez le fil blanc du ventilateur au fil neutre blanc de la source d alimentation Connectez le fil de terre de la maison au fil vert du boîtier du ventilateur Connectez le fil noir du ventilateur au fil noir chaud de la source d alimentation Le ventilateur fonctionnera à vitesse réduite continuellement et aug...

Page 10: ...onsigne du capteur d humidité Dans le cas où le niveau d humidité ambiante de la pièce s élève plus haut que le niveau préréglé le ventilateur s allumera même si la salle n est pas occupée Ceci aide à éviter les conditions qui mènent à la croissance de moisissures AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION 1 Pour régler le nivea...

Page 11: ...se manipulation ou opération de dommages d expédition d abus de mauvaise utilisation de réparation faite ou tentées non autorisées Cette garantie ne couvre pas les coûts d expédition pour le retour des produits à Air King pour la réparation ou le remplacement Air King payera les frais d expédition de retour de Air King après les réparations ou le remplacement de garantie TOUTES LES GARANTIES EXPRE...

Page 12: ...2 2 Passe fil 5S1202032 Qty Description Replacement Part 13 1 Vis 10 de mise à la terre 5S1999002 14 1 Fil de mise à la terre de calibre 14 5S1999003 15 1 Assemblée du compartiment du fil ES80S ES130D 5S1299801 16 1 Faisceau électrique ES80S ES130S 5S2239002 Faisceau électrique ES80S ES130S 5S2239003 17 1 Assemblée du compartiment du fil ES80D ES130D 5S1299803 18 2 Vis 6 de la couverture du fil 5S...

Reviews: