background image

www.airkinglimited.com

6728055 Rev. B 5-14

6 of 12

REPLACEMENT PARTS DIAGRAM

2

1

3

7

1

6

4

5

  # 

Qty.  Description 

Replacement Part # 

  1 

Mounting Rails 

5S1299002 

  2 

6” Metal Collar Assembly 

5S5299100 

  3 

Grill Springs 

5S1202046 

  4    1 

Ceiling Flange 

5S1239024 

  5    2 

Mounting Channel 

5S1239021 

  6 

Blower Assembly 

5S2239008 

  7    1 

Grill Assembly 

5S1239115 

  11    1 

Humidity Sensor Compartment 

5S1239826 

  12    1   Knob 

5S1299802 

All Models

  # 

Qty.  Description 

Replacement Part # 

  10    1 

Wire Compartment Assembly 

5S1239830 

  13    3    Adjustment Knob 

5S1299802 

Specific to Models ESVDGH

  #    Qty.  Description 

Replacement Part # 

 9   1 

Wire Compartment Assembly - ESB80DGH 

5S1239827 

      1 

Wire Compartment Assembly - ESB130DGH 

5S1239828 

Specific to Models ESB80DGH, ESB130DGH

  #    Qty.  Description 

Replacement Part # 

 8   1 

Wire Compartment Assembly - ESB80SGH 

5S1239822 

      1 

Wire Compartment Assembly - ESB130SGH 

5S1239823 

Specific to Models ESB80SGH, ESB130SGH

8

9

10

11

11

11

12

12

12

13

Summary of Contents for ESBGH Series

Page 1: ...ctrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhaust...

Page 2: ...the housing Center the mounting channel in the slots on the housing then from inside the housing tighten the mounting channel nuts so the channel is securely in place Position the housing in the previ...

Page 3: ...the wire compartment cover Connect the two pin connector from the humidistat compartment to the two pin connector from the side of the wire compartment cover These cords will only fit one way into th...

Page 4: ...is detected www airkinglimited com 6728055 Rev B 5 14 4 of 12 SECTION 8 Setting the Humidistat This fan is equipped with a humidity sensor that automatically turns the fan on when humidity is above s...

Page 5: ...unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air K...

Page 6: ...ensor Compartment 5S1239826 12 1 Knob 5S1299802 All Models Qty Description Replacement Part 10 1 Wire Compartment Assembly 5S1239830 13 3 Adjustment Knob 5S1299802 Specific to Models ESVDGH Qty Descri...

Page 7: ...lifi e s en conformit avec tous les codes et normes applicables incluant la construction relative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de g...

Page 8: ...les fentes sur le bo tier puis de l int rieur du bo tier serrez les crous de montage de sorte que le canal soit bien en place Positionnez le bo tier dans le trou pr alablement d coup de sorte qu il so...

Page 9: ...raccordement r installer la soufflante en inversant les instructions l tape 1b de la Section 5 C blage 3 Branchez les c bles 2 broches du ventilateur et les c bles 3 broches de connexion rapide du mot...

Page 10: ...3 fois avant de quitter pour revenir au mode de programmation 3 Une fois que tous les r glages ont t faits le capteur retournera au mode de d tection et le LED clignotera lorsque l occupation de la sa...

Page 11: ...e manipulation ou op ration de dommages d exp dition d abus de mauvaise utilisation de r paration faite ou tent es non autoris es Cette garantie ne couvre pas les co ts d exp dition pour le retour des...

Page 12: ...Compartiment du capteur d humidit 5S1239826 12 1 Bouton 5S1299802 Tous les mod les de pi ce Qt Description de remplacement 8 1 Assembl e du compartiment du fil ESB80SGH 5S1239822 1 Assembl e du compa...