background image

CUL/HVI

Acceptable for use over tub or shower when

installed in a GFCI protected branch circuit.

7

7/8

"

4"

10

7/8

"

9

3/8

"

11"

13

3/4

"

SPECIFICATIONS

EXHAUST FANS

AK110PN

100 CFM/1.5 SONES @ 0.10" wg. • 90 CFM/1.5 SONES @ 0.25 wg.

HVI CERTIFIED 120 Volts, 0.31 amps, 60 hz.

Grill

White, polymeric grill secured in place with torsion springs;
easily removed if necessary, dimensions - 11" x 13

3/4

".

• Blower Wheel

Balanced polymeric dual inlet blower wheel 5

13/32

"  dia. x 4"

depth, 30 paddles, secured in place using 8M hex nut.

• Motor

Enclosed 4 pole electronically balanced permanently split
capacitor motor (PSC); life time lubricated. Motor bearings -
ball. Suitable for continuous operation. Rated 115/120 volts, 60
Hz, 0.31 amps.

• Fan Housing

23 gauge galvanized steel housing, fully sealed.
Overall dimensions 10

7/8

" x 9

3/8

" x 7

7/8

".

• Duct Collar

4" round, zinc plated metal collar adapter. 4" spring loaded
aluminum backdraft damper.

• Ventilating Area

For bathrooms up to 100 sq. ft. For other rooms up to 125 sq. ft.

• Electrical Connections

1/2

" electrical knockouts provided. Easy wiring access via either

internal or external wiring compartment cover.

Canada:

 110 Glidden Road

Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015

U.S.:

 820 Lincoln Drive

West Chester, Pennsylvania  19380-4466
Tel: (877)-304-3785
Fax: (610) 696-8048

Updated 6-06

Specifications subject to change without notice.

• Unit Mounting

The housing will mount in ceilings with  at least 8" of clearance
and through drywall thickness up to 

3/4

", with a rough-in opening

of 11

1/8

" x 9

5/8

". Rated for ceilings insulated to R-40. The housing

will mount either between 16" or 24" on center joists, using the
4 supplied housing mounting rails. The housing mounting rails
can be adapted for overhead mounting (hardware not provided).

• Single Pack Shipping Info

Box Dim: 14

1/8

" x 11

5/8

" x 9

5/8

"

UPC: 0-8316221012-7
Shipping Weight: 11.5 lbs.

C

US

PROJECT

LOCATION

CONTRACTOR

ARCHITECT

ENGINEER

SUBMITTED BY

DATE

FAN

MODEL

CFM

IN

RPM

WATTS

AMPS

SONES

QTY

OPTIONAL EQUIPMENT

NUMBER NUMBER

W.G.

& REMARKS

PERFORMANCE

HVI Sones

Fan Speed

Power

Static Pressure (inches of w.g.)

@ .1 SP

RPM

Watts

0

0.05

0.1

0.125

0.15

0.2

0.25

0.3

Air Flow - CFM

104

102

100

99

98

95

90

71

1.5

1106

29

Reviews: