SPECIFICATIONS
EXHAUST FANS
AS70
70 CFM/5.0 SONES @ 0.10" WG. -HVI CERTIFIED
120 Volts, 0.9 amps, 60 hz.
• Grill
White, polymeric grill secured in place with torsion springs;
easily removed if necessary, dimensions - 10" x 9
5/8
".
• Blower Wheel
One piece polymeric wheel, 4
1/2
" diameter, 1" wide, with 10 fins.
• Motor
Single coil plug-in, two pole motor, life time lubrication, thermally
protected. Rated 120 volts, 60 hz., 0.9 amps.
• Fan Housing
23 gauge galvanized metal housing, dimensions 7
3/8
" x 7
1/2
" x
3
3/4
", double metal thickness mounting tabs.
• Duct Collar
Plastic collar for 3" duct connection, comes complete with built
in non-metallic back draft damper for quiet operation.
• Ventilating Area
For bathrooms up to 70 sq. ft. for other rooms up to 85 sq. ft.
• Unit Mounting
Rated for ceilings insulated to R-40. Designed to mount in
ceilings or walls with at least 4" of clearance. The housing will
mount through drywall thickness up to
3/4
", with a rough-in
opening of 7
3/8
" x 7
1/2
".
• Single Pack Shipping Info
Box Dim: 10
3/4
" x 10
1/8
" x 4
3/4
"
UPC: 0-8316227311-6
Shipping Weight: 4
1/2
lbs.
CUL/HVI
Canada:
110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
U.S.:
820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Updated 2-06
Specifications subject to change without notice.
C
US
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY
DATE
FAN
MODEL
CFM
IN
RPM
WATTS
AMPS
SONES
QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER
W.G.
& REMARKS
Acceptable for use over tub or shower when
installed in a GFCI protected branch circuit.
PERFORMANCE
HVI Sones
Fan Speed
Power
Static Pressure (inches of w.g.)
@ .1 SP
RPM
Watts
0
0.1
0.125
0.5
0.2
0.25
0.3
0.4
Air Flow - CFM
75
70
69
67
65
62
59
52
5.0
2175
50