background image

 July, 2016 

 

 

 
 
701 Frontier Way, 
Bensenville, IL 60106 
Phone: (800) 542-3336 
Fax     : (630) 350-8011             Website:        

AIR-KING.COM 

 

 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SERVICE & INSTALLATION FOR  

K52 & K552  

VACUUM UNIT, AIR / VACUUM UNITS  

UNITS 1200 SERIES

 . 

Summary of Contents for K52

Page 1: ...July 2016 1 701 Frontier Way Bensenville IL 60106 Phone 800 542 3336 Fax 630 350 8011 Website AIR KING COM SERVICE INSTALLATION FOR K52 K552 VACUUM UNIT AIR VACUUM UNITS UNITS 1200 SERIES...

Page 2: ...5 4 General Specifications Page 6 5 Electrical Requirements Page 7 6 Mounting Instructions Page 8 7 Operating Instructions Page 9 8 Basic Maintenance Page 10 9 Replacement of Parts Page 11 12 10 Trou...

Page 3: ...s may be present WARNING VACUUMS EQUIPPED WITH AIR COMPRESSORS K552 750 OR VACUUMS EQUIPPED WITH REMOTE AIR SOLENOIDS K52 9 1 Over inflation of tires may be dangerous Please consult your vehicle owner...

Page 4: ...dels comes with a variety of optional features 1 Models can be set up for free operation or coin operation 2 Cut resistant hose Air Vacuum Air Vacuum Remote units only 3 Single hose reel assemblies Ai...

Page 5: ...er parts of the unit are warranted for ninety days 5 Warranty covers parts and materials only warranty does not include labor or transportation costs of any kind 6 If unit or parts are returned to the...

Page 6: ...r coated with a clear coat finish 5 Separate timer for each function vacuum or air 6 Money box secured with two medco plug locks on the 1200 series vacuum AIR KING MODEL K552 1 High quality H P Indust...

Page 7: ...Breaker C 60 HZ Single Phase The use of the recommended wire size is required for proper operation of all models See wire size guide below If using aluminum wire increase gauge on size Building Vacuum...

Page 8: ...ND MORE THAN 1 INCH ABOVE CONCRETE BECAUSE FLOOR OF VACUUM IS ONLY 2 INCHES ABOVE THE CONCRETE ELECTRICAL REQUIREMENTS K52 K52 9 120 VAC 20 AMP CIRCUIT BREAKER K552 750 120 VAC 40 AMP CIRCUIT BREAKER...

Page 9: ...K552 or a K52 9 Air Vacuum and Air Vac remote follow these instructions A To operate the Vacuum side insert the correct amount of coin or coins into the money slot on the right hand side of the vacuu...

Page 10: ...deco plug locks Turn locks clockwise half of turn until they click Remove keys unit is now secured 3 Cleaning Out Refuse Area 1200 Series Vacuums A Refuse area must be cleaned periodically Refuse area...

Page 11: ...coin boxes bolts are located behind the coin boxes Refer to Basic Maintenance for lock removal 3 Run the power wire from the stub up through the hold provided at the bottom of the unit See wire size...

Page 12: ...d screen and press adhesive side down onto where the old gasket and screen were 5 To install motors follow in reverse the above procedure Air Compressor Replacement for 1200 Series Vacuums 1 Turn Powe...

Page 13: ...bags A Remove A ring from top of the old bag by rotating the A ring counter clockwise until the ring is out of the bag B Remove bottom B ring from the bottom of the bag by rotating the ring out of th...

Page 14: ...If machine still does not start and ground fault kicks out then check fuse underneath the dome See parts identification section for location of fuse See page 8 for fuse replacement Replace fuse push r...

Page 15: ...r clogged or broken hose Check for open door or damaged door gasket if gasket is damaged replace it Problem Vacuum has low suction 1 Check for plugged filter bags Clean out bags if plugged Check for h...

Page 16: ...s 1 thru 7 Are Time setting switches Combine number of seconds to set the time Here Switch 3 20 Seconds Switch 6 160 Seconds are ON for a total run time 20 160 180 Seconds 3 minutes Coin setting Switc...

Page 17: ...540 To adjust time and coins follow directions below Combine Open Switches to select Time Switches must lie flat towards the number in seconds and toward the open Combine Closed Switches to Select Si...