background image

Single Gas Clip and SGC Plus 

User’s Manual Rev 

2.05

 

READ BEFORE OPERATION

Gas Clip Technologies (GCT) Single Gas Clip and 
SGC Plus detectors are personal safety devices 
designed to detect the presence of specific toxic 
gases (Carbon Monoxide (CO) or Hydrogen Sulfide 
(H2S)) or Oxygen (O2) deficiency. Accordingly please 
ensure you have been properly trained on the use of 
the equipment and appropriate actions in the event of 
an alarm condition.  

WARNING

 

 

If the unit is past the “Activate Before Date” 
on the package, please do not activate. 

 

Do not attempt part replacement or 
substitution as this could impair the intrinsic 
safety rating and will void the warranty of the 
product  

 

Before daily use check the following: 
-Sensor and Audio ports are clear of any 
obstructions i.e. debris or blockage 
-Perform the “Self-test” to ensure proper 
operation of visual, audible, and vibrating 
alarms 
-Confirm receipt of a check mark in the 
upper left hand corner signaling a successful 
“Self-test” 

 

Calibrate the O2 detector at least every 30 
days. Make sure to calibrate in a clean air 
environment. See O2 detector section for 
instructions on calibration. 

 

Both the CO and H2S versions of the Single 
Gas Clip and SGC Plus do not require 
calibration for the life of the product, however 
we do recommend bump tests please see 
our bump test recommendations below: 

 Bump Test the detector 

periodically 

by 

challenging the sensor with a known 
concentration of the target gas to be 
detected. Recommended target gas 
concentrations (H2S: 25 ppm, CO: 200 
ppm, O2: 18%). Bump Test can be 
performed either manually or through the 
Clip Dock. If a manual test is to be 
performed make sure to test in a clean air 
environment.  

 

If a unit fails the Self-test or Bump Test 
please discontinue use of the detector  

 

The detector contains a lithium battery that 
must be disposed of by a qualified recycler. 

 

Do not substitute internal components as this 
may interfere with the intrinsic safety of the 
device. 

 

Do not attempt to replace the battery or 
sensor, this product is designed to be 
disposable. Changing these components will 
void the warranty.  

 

If you suspect any malfunction or have any 
technical problems please contact GCT at 
877-525-0808 

Activating the detector 

To activate the detector, press and hold down button for 
approximately 5 seconds. Upon activation, the detector will 
vibrate, flash, and sound the audible alarm. A successful 
activation will display the life remaining in months on the 
detector as 24 months.  

Display Details 

The detector utilizes a special high viewing angle LCD that is 
designed to enhance the screen visibility. In the absence of 
gas, it displays life remaining. In those cases where gas is 
present, the display will automatically shift to a display that 
shows gas concentration and a battery icon.  
*Note the display mode can be changed in the IR Link
software with the "Sensor Reading" and "Life Remaining" 
user options. 

Warning: Users must familiarize themselves with 
the icons in both non-alarm and alarm states 
Warning: If the display is missing icons or cannot 
be clearly read, please contact GCT immediately 

Single Gas Clip and SGC Plus User’s Manual Rev 

2.05

Single Gas Clip and SGC Plus User’s Manual Rev 

2.05

Summary of Contents for Single Gas Clip

Page 1: ...ns H2S 25 ppm CO 200 ppm O2 18 Bump Test can be performed either manually or through the Clip Dock If a manual test is to be performed make sure to test in a clean air environment If a unit fails the Self test or Bump Test please discontinue use of the detector The detector contains a lithium battery that must be disposed of by a qualified recycler Do not substitute internal components as this may...

Page 2: ...ns with a maximum character limit on the User ID of 6 characters The User ID can be changed modified via the IR Link software Screen 5 if applicable If the detector has been exposed to gas exceeding the low alarm set point a value will appear with max next to it This represents the peak value highest that the detector has seen After this screen there will be another screen displaying a value with ...

Page 3: ...events The system stores events by first in first out i e the 26th event will replace the first event and so on This information can be downloaded using the GCT IR Link For each alarm event the detector records the following The detector serial number Bump Test Yes or No Life remaining on the detector Number of self tests performed Number of events Alarm Condition Low High or OL Specific event dat...

Page 4: ...n be turned off Hibernated to suspend the 24 month operation life countdown SGC Plus Hibernation with the IR Link 1 Check that you have installed the IR Link Software and the IR Link USB connections are plugged in 2 Click Read Device on the IR Link Software 3 Note when the monitor is hibernated the event log will be cleared It is highly recommended to save the event log by pressing the save event ...

Page 5: ...nt shall GCT s liability hereunder exceed the purchase price actually paid by the buyer for the product This Warranty does not include 1 Fuses disposable batteries or routine replacement of parts due to the normal wear and tear of the product arising from use 2 Any product which in GCT s opinion has been misused altered neglected or damaged by accident or abnormal conditions of operation handling ...

Reviews: