Single Gas Clip and SGC Plus
User’s Manual Rev
2.05
READ BEFORE OPERATION
Gas Clip Technologies (GCT) Single Gas Clip and
SGC Plus detectors are personal safety devices
designed to detect the presence of specific toxic
gases (Carbon Monoxide (CO) or Hydrogen Sulfide
(H2S)) or Oxygen (O2) deficiency. Accordingly please
ensure you have been properly trained on the use of
the equipment and appropriate actions in the event of
an alarm condition.
WARNING
If the unit is past the “Activate Before Date”
on the package, please do not activate.
Do not attempt part replacement or
substitution as this could impair the intrinsic
safety rating and will void the warranty of the
product
Before daily use check the following:
-Sensor and Audio ports are clear of any
obstructions i.e. debris or blockage
-Perform the “Self-test” to ensure proper
operation of visual, audible, and vibrating
alarms
-Confirm receipt of a check mark in the
upper left hand corner signaling a successful
“Self-test”
Calibrate the O2 detector at least every 30
days. Make sure to calibrate in a clean air
environment. See O2 detector section for
instructions on calibration.
Both the CO and H2S versions of the Single
Gas Clip and SGC Plus do not require
calibration for the life of the product, however
we do recommend bump tests please see
our bump test recommendations below:
Bump Test the detector
periodically
by
challenging the sensor with a known
concentration of the target gas to be
detected. Recommended target gas
concentrations (H2S: 25 ppm, CO: 200
ppm, O2: 18%). Bump Test can be
performed either manually or through the
Clip Dock. If a manual test is to be
performed make sure to test in a clean air
environment.
If a unit fails the Self-test or Bump Test
please discontinue use of the detector
The detector contains a lithium battery that
must be disposed of by a qualified recycler.
Do not substitute internal components as this
may interfere with the intrinsic safety of the
device.
Do not attempt to replace the battery or
sensor, this product is designed to be
disposable. Changing these components will
void the warranty.
If you suspect any malfunction or have any
technical problems please contact GCT at
877-525-0808
Activating the detector
To activate the detector, press and hold down button for
approximately 5 seconds. Upon activation, the detector will
vibrate, flash, and sound the audible alarm. A successful
activation will display the life remaining in months on the
detector as 24 months.
Display Details
The detector utilizes a special high viewing angle LCD that is
designed to enhance the screen visibility. In the absence of
gas, it displays life remaining. In those cases where gas is
present, the display will automatically shift to a display that
shows gas concentration and a battery icon.
*Note the display mode can be changed in the IR Link
software with the "Sensor Reading" and "Life Remaining"
user options.
Warning: Users must familiarize themselves with
the icons in both non-alarm and alarm states
Warning: If the display is missing icons or cannot
be clearly read, please contact GCT immediately
Single Gas Clip and SGC Plus User’s Manual Rev
2.05
Single Gas Clip and SGC Plus User’s Manual Rev
2.05