background image

10

TROUBLE SHOOTING.

PUMP

 

Pump not working

 

> Check that the 12v system of your AIR OPUS

®

 is turned on. 

 

> Check 20A fuse (yellow) on the fuse panel in the unit under the fridge, 

 

   replace if needed.

 

Pump seems to cut out before tent is fully inflated

 

> Check that the pump pressure dial is set to the correct setting on 7PSI. 

 

> Ensure that AIR poles are not folded, which would restrict AIR flow, on occasion they    

 

   may need gentle assistance in popping up. 

 

The main tent is taking a longer time than usual to inflate

 

> Ensure that all external AIR release valves are in the closed position. 

 

> Ensure that your AIR OPUS

®

 leisure battery is fully charged. 

 

The awning is taking a longer time than usual to inflate.

 

> Ensure that all AIR release valves are in the closed position. 

 

> Ensure that your AIR OPUS

®

 leisure battery is fully charged. 

 

> Ensure that the pump extension hose is fastened properly, as any AIR leaks will prevent  

 

   the pump from reaching its correct pressure. 

OTHER

For any other troubleshooting issues please contact your place of purchase for further assistance. 
Spare parts are available if required. Please refer to the warranty section on Page 9 for further 
information on warranty inclusions and exclusions. 

Summary of Contents for OFC195B-102

Page 1: ...AIR TENT AWNING HANDBOOK Tent Model No OFC195B 195 Awning Model No OFC195B 102 OFC195C AO UM 0717 Rev B...

Page 2: ......

Page 3: ...Down 4 Weathering Fabric 5 Inflation 6 Deflation 7 Safety AIR TENT BUNGEE SECURING POINTS AIR AWNING 1 Parts List 2 Assembly 3 Pack Down TROUBLESHOOTING 1 Pump 2 Other WARRANTY WOOD MAINTENANCE IF FIT...

Page 4: ...e the pump will automatically cut out 9 Disconnect pump hose from inflation valve and fit inflation valve screw cap to prevent any loss of tent pressure 10 Close all internal valves keep valves closed...

Page 5: ...t damp canvas will develop mildew mould very quickly and damage your canvas permanently The inside and outside of your AIR tent can be cleaned but only with fresh clean water and a damp cloth UNDER NO...

Page 6: ...STRUCTION WILL RESULT IN BLADDER FAILURE Please note that it may be necessary to monitor the AIR pressure in your AIR tubes from time to time especially if the weather is fluctuating or the temperatur...

Page 7: ...it is wet please dry it as soon as possible to avoid damage to the fabric and components Open all internal AIR valves Then open all external AIR valves found in the external valve pockets There are 5...

Page 8: ...ENSURE THAT BUNGEES ARE PULLED SIDEWAYS RATHER THAN DIRECTLY DOWN TO EXTEND THEM INITIALLY BEFORE PULLING THEM OVER THE CLEATS THIS WILL PREVENT THE EYELETS FROM CATCHING ON THE BUNGEES AND CAUSING DA...

Page 9: ...centre roof supports Securing 4 points in total 2 on each bed end As shown below titled CENTRE ROOF SUPPORTS REAR 6 Locations to be used as shown in green and numbered below OUTER ROOF SUPPORTS CENTR...

Page 10: ...R awning onto the zip on the front of the AIR tent The zip is located under the flap above the front door 5 Temporarily peg the 4 corners of the flysheet in line with your AIR OPUS tent You may need t...

Page 11: ...ays and entrances Adjust the guy lines and storm straps as necessary 14 Your AIR awning includes a groundsheet which may be used by carefully matching its Velcro to the relevant Velcro on the awning f...

Page 12: ...the Velcro patches attaching the AIR tent and the AIR awning Then unzip the AIR awning from the front zip located on the AIR tent 4 Carefully fold the AIR awning canvas and place it back into carry st...

Page 13: ...e Ensure that all external AIR release valves are in the closed position Ensure that your AIR OPUS leisure battery is fully charged The awning is taking a longer time than usual to inflate Ensure that...

Page 14: ...e resulting from improper storage or maintenance Negligence or damage resulting from unauthorised repairs Bladder damage including but not limited to over inflation unnecessary release of the sealed z...

Page 15: ...or commercial use by rental companies Transportation or shipment costs to and from the manufacturer or their recognised agents dealers for repair or assessment against a warranty claim THIS DOES NOT A...

Page 16: ...RE The surfaces of the timber worktops have been finished with specifically formulated oil The oil is formulated to be safe for the preparation of food and to enhance the wood colour and grain pattern...

Page 17: ...s Conditions and Warranty information can be found online at www opuscamper co uk terms conditions html Photographs and diagrams are for illustration purposes only Actual product may vary and any spec...

Reviews: