background image

 

 

 

ONE - YEAR LIMITED WARRANTY 

Air Quality Engineering, Inc., warrants to the original purchaser, subject to the conditions below, that should 
the product covered by this warranty 

(“product”) fail to perform by reason of improper workmanship or 

material, Air Quality Engineering, Inc., (AQE) will, during the period of one (1) year from the date of original 
purchase either (i) replace the Product or (ii) provide all necessary parts to repair the Product, without 
charge. The decision to replace the Product or the necessary parts shall rest solely with AQE. This one-year 
limited warranty does not apply to main filter elements. Air Quality Engineering, Inc., will replace without 
charge the main filter elements during the period of thirty (30) days from the date of original purchase if the 
main filter elements fail to perform by reason of improper workmanship or material. This warranty is valid 
only under the following conditions:

 

 

CONDITIONS 

1.  AUTHORIZATION: Purchaser will contact Air Quality Engineering, Inc., 800-328-0787, for  authorization, 

returned goods authorization number (RGA) and shipping address. AQE will direct purchaser to either 
return the necessary parts or the Product at AQE’s option.

 

 

2.  PROPER DELIVERY: The shipping, freight prepaid, or delivery of the parts or the Product to Air Quality 

Engineering, Inc., in either its original carton or in a carton assuring similar protection of the Product 
with returned goods number (RGA) clearly displayed on the outside of the carton.

 

 

3.  UNAUTHORIZED REPAIR: A showing by the original purchaser that the Product has not been altered, 

repaired or serviced by anyone other than an authorized service technician using genuine AQE parts.

 

 

4.  UNAUTHORIZED PARTS: A showing by the original purchaser that the Product has had only genuine Air 

Quality Engineering, Inc., parts and filters used in its operation and maintenance.

 

 

5.  SERIAL NUMBER INTACT: A showing by the original purchaser that the Serial Number has not been 

altered or removed.

 

 

6.  MISUSE: A showing by the original purchaser that the Product has not been involved in an accident, 

freight damaged, misused, abused or operated contrary to the instructions contained in the 

Owner’s 

Manual.

 

 

Air Quality Engineering, 

Inc.’s, sole responsibility shall be to repair or replace the Product within the terms 

stated above. AQE shall not be liable for any consequential damages resulting from and breach of warranty, 
express or implied, applicable to the Product. Some states do not allow the exclusion or limitation of 
consequential damages so this limitation may not apply to you.

 

 

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE 
WARRANTIES OF MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not

 

allow limitations on how long an implied warranty lasts so the above limitation may not apply to you.

 

 

This warranty gives you specific legal rights and you may also have other rights that vary from state to state.

 

 

 

MANUFACTURER & WORLDWIDE DISTRIBUTOR OF SMOKEMASTER® AIR CLEANING SYSTEMS

 

 

PN 51414 Rev. C 

Printed in the USA 

 
 

These air cleaners have not been tested for compliance to California Air Resource Board requirements and are not 
available for sale, resale or installation in California. 

CERTIFICATE OF WARRANTY

 

Page 14

S M O K E M A S T E R   C - 1 2   O W N E R ' S   M A N U A L 

Pure n Natural Systems, Inc.  |  purennatural.com  |  1-800-237-9199

Summary of Contents for SMOKEMASTER C-12

Page 1: ...ior written consent of Air Quality Engineering Inc All statements technical information and recommendations in this manual or related documents are believed reliable but the accuracy and completeness thereof arenot guaranteed or warranted and they are not intended to be nor should they be understood to be representation or warranties concerning the products described Specifications are subject to ...

Page 2: ...aden air successively through the prefilter the cell ionizing section and the cell collector section The ionizing section imparts an electrical charge to the individual particles that are then drawn by electrostatic forces to the oppositely charged collector plates Cleaned air is then discharged back into the room The electronic cells must be washed periodically to maintain efficient performance F...

Page 3: ...f no less than 15 cubic feet of air per minute per person Additional ventilation may be required for toxic contaminants In any event the air cleaner must be used only in areas that are ventilated for human occupancy in order to dissipate any incidental generation of ozone DIMENSIONS 25 x 25 x 11 635 mm x 635 mm x 279 5 mm WEIGHT 79 Lbs 36 Kg shipping 69 Lbs 31 Kg installed including electronic cel...

Page 4: ...or Allows easy access to components for periodic cell and prefilter cleaning Safety interlock discharges allpower when the door is opened Built in test button assures collector performance Mounting Mounts on wall brackets or with steel suspension rods For mounting directly to a joist ceiling lag screws areavailable Plug Plugs into any regular 120 or 240 volt grounded outlet depending on voltageord...

Page 5: ... 07071 07089 5 Door Interlock Switch 10106 10106 6 Motor Kit 05299 05014 7 Fan 37009 37009 8 Power Cord 42078 42027 9 Control Switch 10110 10110 10 Indicator Light 10097 10097 11 Intake Grille Light 20025 20025 Intake Grille Black 20026 20026 NP Ionizer Wire 38004 18 38004 18 C 12 Parts List Page 5 S M O K E M A S T E R C 1 2 O W N E R S M A N U A L Pure n Natural Systems Inc purennatural com 1 80...

Page 6: ...ck the existing air circulation in the room The C 12 should be installed so that it aids the circulation already established When airflow patterns are not immediately apparent observe the smoke from a cigarette in various locations within the room Figure 6 C 12 Installation Dimensions Ceiling Mounting The C 12 is mounted by suspending it from the ceiling The mounting holes in holes in the C 12 are...

Page 7: ...also be mounted using 3 8 in 10 mm diameter threaded steel rods available in many hardware stores Four steel rods will be required WALL MOUNTING Two wall mounting brackets are used to support the C 12 They are included in an accessory package along with a blank plate to block off the outlet louvers on the side of the air cleaner which will be against the wall The two brackets must be mounted on th...

Page 8: ... C 12 junction box cover Figure 12 2 Disconnect and discard the power cord the solderless connectors and strain relief Plug the power cord hole with the plug provided 3 Run conduit from the power supply to the junction box through the appropriate knockout Fish wires to junction box 4 Connect lead wires with solderless connectors including ground green wires Proper grounding of this device is manda...

Page 9: ...to work right refer to the Electrical Troubleshooting section SAFETY INTERLOCK SYSTEM In order for all air cleaner functions to receive operating power the grille must be securely in position This actuates the safety interlock switch The air cleaner will not function without the grille inplace FAN SWITCH Your electronic air cleaner has an Off Low Med Hi switch The electronic collection system and ...

Page 10: ...llow better release of contaminant when washing 7 Check the electronic cells for broken wiresand bent collector plates The cells may be installed in the air cleaner and energized The indicator light may remain off during the normal two hour drying time However if annoying arcing occurs during this period the cell may be removed to dry 8 CELL CLEANER IS REUSABLE SAVE FOR REPEATED USE Replace cleani...

Page 11: ...power at the fuse or circuit breaker 2 Open the intake grille Remove the cells to provide access to the motor 3 Remove the fan blade from the motor 4 Disconnect the fan motor leads at the plastic connector near the fan motor C 12 POWER SUPPLY REPLACEMENT PROCEDURE 1 Disconnect power from the unit 2 Disconnect quick connect terminals from power supply Unplug power supply wire harness 3 Remove 4 scr...

Page 12: ... cleaner to function effectively without arcing Remove all parts of the broken wire If necessary the cell may be temporarily used with one wire missing 1 Use care to avoid damage to the spring connector or other parts of the cell during the installation 2 Hook one end of the ionizing wire over the spring connector at one end of the cell 3 Hold the opposite eyelet with a needle nose pliers and stre...

Page 13: ...N ON LAMP OFF 1 If the fan is on and the light is out the problem is with the electronic cell or high voltage power supply 2 To determine which component is faulty Remove the electronic cell and operate the air cleaner If the light does not come on then the high voltage power supply will have to be replaced 3 If the indicator light does come one the problem is with the electronic cell Check the ce...

Page 14: ...r serviced by anyone other than an authorized service technician using genuine AQE parts 4 UNAUTHORIZED PARTS A showing by the original purchaser that the Product has had only genuine Air Quality Engineering Inc parts and filters used in its operation and maintenance 5 SERIAL NUMBER INTACT A showing by the original purchaser that the Serial Number has notbeen altered or removed 6 MISUSE A showing ...

Reviews: