background image

9

13

OPERATION CYCLE  OF  TARGET

Summary of Contents for Plus AR-3.0

Page 1: ... all instructions before using the Air Relax Plus system Keep this manual near to the system for quick reference This manual presents details required by users to prevent any danger or property loss for safe use of this system PLUS ...

Page 2: ... Contraindications Operation and Components Display Screen Operation Buttons Operation Cycles How to Use the Air Relax Plus System Maintenance and Storage Troubleshooting Warranty Return Policy Specifications Electromagnetic Compatibility 02 03 06 07 08 09 10 12 14 19 20 21 22 23 24 02 ...

Page 3: ... damage WARNING For your safety and to avoid property damage please read this manual carefully and use as indicated Non Compliance may cause serious injuries or death and or severe property damage Do not use the system in any way other than the usage stated in the manual Do not use this system if you are experiencing inflammation an infection open wounds or bleeding at or near the site of applicat...

Page 4: ...id the risk of electrical shock do not use the system in near water such as a kitchen bathroom sauna or swimming pool Keep the system away from heating appliances such as ovens microwaves hot cooking utensils or high pressure cookers This may cause a degradation of the battery pack and or system malfunction If the battery pack is not in use for extended duration charge the unit once every month If...

Page 5: ... not use the system beyond the specified humidity range 35 R H 85 R H non condensing but not requiring a water vapor partial pressure greater than 5 000 Pa and an atmospheric pressure range of 800 hPa to 1060 hPa To prevent any damage to the system keep it away from dust lint or any dirt Use only accessories approved by the Manufacturer Other accessories may damage the system or interfere with sys...

Page 6: ... Keep dry Separate collection for waste electrical and electronic equipment On base of control unit and battery pack Keep away from sunlight On base of control unit and package On base of control unit and package On base of control unit and package On base of control unit and package On base of control unit and package Transportation storage humidity limitation Transportation storage atmospheric p...

Page 7: ...have a contraindication requiring the use of any medical device Do not use this system if you have any of following conditions Acute pulmonary edema Acute thrombophlebitis Acute congestive cardiac failure Acute infections Osteoporosis Deep vein thrombosis DVT Episodes of pulmonary embolism Wounds lesions or tumors at or near the site of application Where increased venous and lymphatic return in un...

Page 8: ...8 Leg Garments 9 AC Adapter 10 Battery Pack Optional 11 Arm Garment Optional 12 Shorts Garment Optional OPERATION COMPONENTS 08 10 9 The Air Relax plus control unit takes air from the surrounding environment and sends it through silicon hoses into four individual air chambers inside of the Air Relax Plus garment 5 6 7 ...

Page 9: ...he power status MODE P S F Displays the operation cycle mode that is currently selected TARGET Displays status of TARGET operations Selected area on the chamber lights up PRESSURE Displays the level of air pressure TIME Displays and operates when the TIME button is pressed When selected the Time Display lights up to indicate 30 minutes session in operation ...

Page 10: ...pressed during a current session another 15 minutes starts from the time the last button is pressed Use this button to access selection of a P S F cycle mode Progressive Cycle Mode Sequential Cycle Mode Full Massage Cycle Mode In case the TARGET or MODE button is pressed during operation the MODE light turns off and the newly selected mode turns on 10 inflation holding inflation holding inflation ...

Page 11: ...e PRESSURE Button Use this button to adjust the pressure level This will change the intensity of the massage A lower pressure setting will apply a light massage while a higher pressure setting will apply a more intense massage If the massage is too intense lower the pressure level using this button The default pressure setting is level 1 Level 1 60 mmHg Level 2 100 mmHg Level 3 140 mmHg Level 4 17...

Page 12: ...OPERATION CYCLES holding holding holding holding 12 OPERATION CYCLE OF MODE ...

Page 13: ...9 13 OPERATION CYCLE OF TARGET ...

Page 14: ...uctions for use that accompany the battery pack 1 The hoses should not be twisted or folded 2 Connect the hose plug to the air socket on the control unit making sure the arrow sign is facing up 3 The hose plug should be connected fully to prevent air from leaking out 14 HOW TO USE THE AIR RELAX PLUS SYSTEM FOR YOUR SAFETY AND TO AVOID PROPERTY DAMAGE Read this manual carefully and use as indicated...

Page 15: ...rso 4 Close the zipper all the way up to the top being careful that your clothes are not caught in the zipper 5 Place the zipper flat as in the picture and secure the Velcro strap firmly 15 3 Put on the Garment The garment is not sterile do not place directly against open wounds sores rashes infections or stitches A layer of clothing between garment and skin is recommended Remove any jewelry or wa...

Page 16: ...he fastening strap around torso under the free arm 4 Fasten the strap at the torso and adjust the length by pulling on the buckle for a comfortable fit Using pressure over 100mmHg Level 2 with the arm garment is not recommend Attach the Velcro to prevent the air pressure from causing the zipper to unzip pop while the upper chambers are filling up If this happens simply shut off your control unit a...

Page 17: ...ment is too tight reduce the pressure immediately or turn the control unit off 5 The shorts garment has two fastening straps on each side Bring each strap at the torso and fasten it Adjust the length by pulling the loop for a comfortable fit 17 If you are pregnant or suspect you may be pregnant do not use the Air Relax Shorts garment Using pressure over 100mmHg Level 2 with the shorts garment is n...

Page 18: ...ate for 30 seconds before you remove it If other buttons are pressed during a current session another 15 minutes starts from the time the last button is pressed At the start of a session a few inflation cycles are used to calibrate the pressure based on your limb s or body circumference The first cycle or two may take a longer time to fill completely Recommended session time is 15 30 minutes befor...

Page 19: ... R H non condensing Atmospheric pressure 700 hpa to 1060 hPa Store in a cool dry and well ventilated area Optimum storage is achieved at room temperature Surface wipe only Do not machine wash Do not dry clean Do not use bleach Do not iron tumble or force heat dry 19 MAINTENANCE The control unit is not a waterproof device Do not apply a direct stream of any liquid onto the control unit submerge the...

Page 20: ...Check the electrical wall outlet Verify AC Adapter is securely connected to the AC Adapter socket on the control unit Charge the external battery pack Contact Air Relax Charge the external battery pack Contact Air Relax Check for physical damage on connectors Check hose bundles for kinks twists and fold Check if hose bundles are securely connected to the control unit garments and connectors Check ...

Page 21: ...AND ARE LIMITED IN DURATION AS STATED ABOVE EXCEPT AS EXPRESSLY STATED ABOVE AIR RELAX SHALL HAVE NO LIABLITY OR RESPONSBILITY TO ITS CUSTOMERS OR ANY OTHER PERSON OR ENTITY WITH RESPECT TO ANY LIABLITY LOSS OR DAMAGE CAUSED DIRECTLY OR INDIRECTLY BY USE OR PERFORMANCE OF THE PRODUCT OR ARISING OUT OF THE USE INABLILTY TO USE OR ANY BREACH OF THIS WARRANTY INCLUDING BUT NOT LIMITED TO ANY DAMAGES ...

Page 22: ...efund 5 If you refuse delivery of your order for any reason you will be refunded the cost of your order less the shipping fees once your item is received and inspected 6 All partial or full refunds will be posted to the credit card used for purchase 7 Air Relax is not responsible for items lost or damaged during shipping RETURN SHIPPING DIRECTIONS Step 1 Contact Air Relax or an Air Relax authorize...

Page 23: ...xture with air or with oxygen or nitrous oxide 18 V 2 A This marking on the show on the product or its literature indicates that is should not be disposed with other household waste at the end of its working life to prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sust...

Page 24: ...MSI MUL AR 3 0 REV 1 19 04 16 MODEL AR 3 0 9535 Brasher Street Pico Rivera CA 90660 USA 1 525 821 5225 www air relax com www air relax eu PLUS ...