STEP 1)
Secure a primary air source of sufficient air flow and discharge pres
-
sure. The number and type of respirators being used determines the
flow rate and pressure required.
STEP 2)
Check airline monitor for fresh 9 volt batteries and turn unit on. Connect
the remote signal cable, 115 VAC plug, and air sample hose to the monitor.
Place the “ON/OFF/TEST” switch to the “ON” position. Allow 30 seconds
for the readout to stabilize. If a reading other than “00” is displayed, cali
-
bration of the monitor may be necessary. See calibration procedure.
Note: Remote signal cable does not apply to BB15 series.
STEP 3)
Connect the extension cord to a 115 VAC receptacle.
Note: The CO monitor can run off the 9 volt batteries if AC power is not
available.
STEP 4)
Connect the optional remote alarm (DC only) assembly to the remote
alarm jack.
Note: This step does not apply to BB15 series.
STEP 5)
Close the flowmeter by turning the control knob fully clockwise. Do not
over-tighten.
BREATHER BOX™ SETUP AND OPERATION
Note: Always operate the Breather Box™ in the upright positi on. Failure to comply may result in one or all
of the following:
1) Auto drains will not functi on properly. This may result in the contaminati on of the CO monitor and cause
oil/water to be passed through respirator hose and into the worker’s mask.
2) Auto drains may become clogged.
3) Filters may accumulate moisture and/or contaminati on.