1 .  Remove the Camera Handpiece from the holder . 
2 .  Insert  the  Camera  Handpiece  tip  between  the  second  and  third  layers 

(between the outer paper and plastic layers) with the camera/light source 
facing towards the paper layer . See A .

3 .  Push the Camera Handpiece completely in until the tip is fully inserted into 

the narrow tip of the sheath . See B .

4 .  Gently squeeze the illuminated tip of the Camera Handpiece between the 

thumb and index finger to ensure that the optically clear area of the cam-
era cover is flat against the lens tip . See C .

5 .  Peel away and discard the top plastic layer and the bottom paper layer . 

See D .

NOTE: 

For optimum image clarity, the optically clear section of the sheath must be aligned with the camera 

lens by facing the camera/light source section of the handpiece down toward the paper layer.

Disposable  Camera  Cover  Installation  - 

Install a new camera cover 

on the Camera Handpiece for each patient as follows

:

PRE-OPERATION

2

The camera cover must be used for only one patient and disposed 

of properly in accordance with local code.

Camera Cover Installation

POLARIS 

CAMERA 

HANDPIECE

LENS

CAMERA 

COVER

SQUEEZE

PLASTIC 

LAYER 2

PLASTIC 

LAYER 1

PAPER 

LAYER 4

PAPER 

LAYER 3

 

 

 

 

 

 

 

 

 

 

B

A

D

C

The Polaris System should be used with a Camera Cover covering the handpiece. 

Make sure to use a new disposable Camera Cover for each patient.

Summary of Contents for Polaris D7500

Page 1: ...Operator s Manual Universal I ntraoral Vid eo Camera System Part Number D7500 ...

Page 2: ...haracteristics 22 Accessories 23 VISIX Imaging Software 24 Warranty 25 On Line Warranty Registration 25 FOREWORD Air Techniques has prepared this document as a guide to the proper use of the Polaris Universal Intraoral Video Camera System Review and follow the guidelines included in this Operator s Manual to ensure that your Polaris System gives you the highest level of service For product support...

Page 3: ...ecting any device to the Polaris System that does not meet the equivalent safety requirements of the system may reduce the safety effectiveness of the Polaris System Unplug the system components from power before performing cleaning procedures Contraindications None known Do Not Attempt Internal Service The interior of the camera is only accessible by removing hardware with tools and should only b...

Page 4: ...nts This manual covers the installation operation and maintenance of Polaris Camera Handpiece with Control Module Power Supply Adapter and Cables D7500 Polaris Camera Handpiece D7520 Control Module with Power Supply Adapter and Cables D7560 Review and follow the guidelines included in this Operator s Manual to ensure that your Polaris System gives you the highest level of service For product suppo...

Page 5: ...rized software The manufacturer regard themselves as being responsible for the equipment with regard to safety reliability and proper functioning only if assembly resetting changes or modifications and repairs have been carried out by an authorized dealer and if the equipment is used in conformity with the instructions contained in this manual The device conforms to the relevant safety standards v...

Page 6: ...e following lists the components included with the Polaris System Polaris System Part Number D7500 includes Item Quantity Contents of D7520 Camera Handpiece Box Camera Handpiece 1 Disposable Camera Covers Sample Pack 20 Camera Handpiece Instructions 1 Contents of D7560 Control Module Box Camera Control Module 1 Dual Lock Fastener Kit 1 Handpiece Cable 15 feet 1 Power Supply Adapter 1 RCA Male Comp...

Page 7: ...structions Part Numbers D7000 On line Registrati on Quickly and easily register your new Polaris System on line Just have the product model and serial numbers available Then go to either the Air T echniques web site www airtech niques com or the ALLPRO Imaging web site www allproim aging com click the Warranty Registration link and complete the registration form This on line registration ensures a...

Page 8: ...en operated directly connected to only a video monitor the connected monitor displays high resolution live video images taken by the Camera Handpiece Power Supply Adapter The 15 watt power supply adapter connects to the Control Module to provide 12 VDC power for operating the Polaris System Camera Handpiece Cable This 15 foot multi conductor cable with quick disconnect connectors at each end inter...

Page 9: ...Intel 32 bit processor Microsoft Windows XP Professional 64 bit Edition with Service Pack 2 or later for an Intel 64 bit extended x64 processor Microsoft Windows Vista Business Enterprise or Ultimate with Service Pack 1 or later for an Intel 32 bit or an Intel 64 bit extended x64 processor Microsoft Windows 7 Professional Enterprise or Ultimate for an Intel 32 bit or an Intel 64 bit extended x64 p...

Page 10: ...ware installation that supports the 2 button handpiece Typical keypad actions provided below NOTE Simultaneously depressing both keypad buttons for approximately 3 seconds deactivates the Camera Handpiece LED light source This is commonly used when imaging an X ray on a light box 1 Top Keypad Button Press and release to send a Button 1 command to the PC While the specific function performed depend...

Page 11: ...lamp illuminates and the camera is operational The 12 VDC is removed and the camera is turned off when the switch is set in the STANDBY position and the LED power indicator lamp extinguishes Control Module Front Panel Controls and Indicators Control Module Rear Panel Connectors 12 VDC Connector Provides connection of the 12 VDC operating power from the Power Supply Adapter S VIDEO Connector A 4 pi...

Page 12: ...iant user supplied streaming video software application such as Visix Perform the following procedures to install the Polaris System Control Module Location Locate the Polaris Control Module on a table top cart or any flat stable surface convenient to an AC wall outlet and associated computer system monitor It can also be installed hanging under a table top under the chair or on the computer using...

Page 13: ...onal 6 9 30 and 50 foot lengths are available from your authorized Air Techniques Dealer at an extra cost Connector Key Camera Handpiece Polaris Handpiece Cable Polaris Handpiece Holder with Chair side Adapter Installing the Chair side Adapter is as easy as deciding on a location for maximum convenience and securing it to an empty customer supplied standard Handpiece Holder Refer to the illustrati...

Page 14: ...ROL MODULE USB 2 0 HIGH SPEED HIGH POWER 500mA PORT NOTES On PC s that have both front and rear USB 2 0 high speed ports it is recommended that the camera be connected to one of the rear mounted ports for best results Minimum PC processor and operating system requirements are listed in the Preinstallation Information of this manual A DirectX 9 user supplied compliant streaming video capture softwa...

Page 15: ...or of a video monitor or a computer with a capture card as required REAR OF PC Optional Video Connections Video Monitor Polaris Control Module Rear Panel Video Capture Card Composite Video RCA Connector S Video 4 Pin Mini DIN Connector Composite Video RCA Connector S Video 4 Pin Mini DIN Connector Optional S Video Cable to Video Monitor or PC Capture Card Composite Video Cable to Video Monitor or ...

Page 16: ...olaris System A Microsoft Driver Not Signed statement may appear If it does click Continue to proceed with installation USB Device Driver Installation Before connecting the Polaris System to your computer or attempting to use it for the first time run the Setup program on the Polaris System Drivers and Utilities Disk included with the Polaris System The supplied CD provides the device drivers need...

Page 17: ...plastic layer and the bottom paper layer See D NOTE For optimum image clarity the optically clear section of the sheath must be aligned with the camera lens by facing the camera light source section of the handpiece down toward the paper layer Disposable Camera Cover Installation Install a new camera cover on the Camera Handpiece for each patient as follows PRE OPERATION 2 The camera cover must be...

Page 18: ...orm the operations that apply to the video capture software that is being used If not follow the General USB Driver Check procedure provided below 7 If connecting to an analog video monitor verify that live video from the camera is correctly displayed on the video monitor 8 Place the camera back into the handpiece holder and verify that the camera s white LEDs turn off ACTIVATION NOTE When all cam...

Page 19: ...he front panel LED indicator lamp extinguishes 2 Remove the Camera Handpiece from the handpiece holder and observe that the computer display shows the high resolution live video images taken by the camera 3 If desired rotate the lens head left or right from center 4 Place the camera lens window over area of interest and view image on computer display monitor 5 Press and release the top keypad butt...

Page 20: ... following a If a live image is correctly displayed exit from the application and make sure that the imaging software application is configured correctly b If a live image is not displayed exit from the application and check the handpiece Polaris Handpiece Cable and USB driver file installation 4 Reset the driver s video settings by performing the following a On the Polaris Demostration Program sc...

Page 21: ...System components before performing cleaning procedures Do not attempt any internal service of Polaris System components Contact your local autho rized Air Techniques dealer for service Failure to heed this warning may result in equipment damage and voiding the warranty MAINTENANCE Do not spray cleaning liquids or disinfectants directly on the camera handpiece Use care not to allow liquids to run ...

Page 22: ...d Viewing Angle 42 Degrees horizontal Operating Temperature 10 to 40º C 50 to 104º F Storage Temperature 0 to 70º C 32 to 158º F Humidity 10 to 90 non condensing Classifications Portable Continuous Operation Class 2 Type BF Protection for Ingress of Water Ordinary Flammable Atmosphere Cannot use in the vicinity of flammable anesthetic mixtures of air oxygen or nitrous oxide Refer to page 9 for the...

Page 23: ... foot Composite Video Cable RCA RCA B3554 6 foot USB 2 0 High Speed Cable Type A Type B D7170 Camera Handpiece Holder with Chair side Adapter D7563 Drivers and Manual CD containing PDF version of Operator s Manual USB Device Drivers Demonstration Program and Utilities Adobe Acrobat Reader 74500 VISIX Imaging Software 5 Licenses see page 24 Replacement Disposable Camera Covers for Camera Handpiece ...

Page 24: ...e images to personal preferences with our simple Set Up 1 2 3 tool Exposure Our Stop Light Exposure System is a unique indicator to ensure optimum data capture It helps you acquire great images by monitoring X ray exposure Viewing VISIX provides automatic image mounting that is completely customizable Flexibility VISIX includes a built in bridging solution to over 35 Practice Management Software t...

Page 25: ...factory through your authorized Air Techniques dealer will be repaired or replaced at our option at no charge provided that our inspection shall indicate it to have been defective Dealer labor shipping and handling charges are not covered by this warranty This warranty does not apply to damage due to shipping misuse careless handling or repairs by other than authorized service personnel Warranty v...

Page 26: ...26 NOTES ...

Page 27: ...27 NOTES ...

Page 28: ...o systems We have been manufacturing quality products for dental professionals since 1962 Air Techniques products are only distributed through authorized dealers A T 2000 XR AcadiaJ AccentJ AirStar CleanStreamJ GuardianJ Peri Pro PolarisJ ScanX SensaJ SpectraJ STSJ VacStarJ VisixJ 1295 Walt Whitman Road Melville NY 11747 3062 Website www allproimaging com East Coast 1 800 AIR TECH 1 800 247 8324 W...

Reviews: