background image

 

 

12 

 

Maintenance 
 

 

When replacing the composite filter that contains the HEPA and carbon filter, the pre-

filter should be brushed to remove the dust.  

 

For a better maintenance, check carefully whether the device, circulating air flow, filters, 

digital control panel, etc. are working properly.  

 

If the machine is not in use for a long period of time, it should be unplugged and stored 

with a large protective covering.  

 

 

ITEM 

HOW TO CHECK IT? 

FREQUENCY 

External wiring 

Visually inspect the cable and plug. If the fuse 

has blown, the plug or power cord heats up or 

appears to be damaged, turn off the device and 

immediately contact our AIR8 specialists.

 

3 months 

Fan and motor 

The fan must rotate smoothly and without 

generating unusual noise. If unusual noise is 

heard, check if there is an external element in 

the ventilator. If the motor generates unusual 

noise, please contact our AIR8 specialists. 

12 months 

Pre-filter 

Make sure the surface is not damaged.  

Pre-filter has to be cleaned every 3 months. 

3 months 

UV-GI sterilisation light 

When replacing the HEPA filter, the light tube 

has to be visually inspected.

 

6 months 

 

 

 

 

 

 

 

 

 

 

 

 

 

This product must not be disposed of with household waste. 

This air purifier must be disposed of at 

a recycling point for electronic and electrical equipment. 

Summary of Contents for 1000i PRO

Page 1: ...Clean Air System 1000i PRO ...

Page 2: ...2 Table of contents Unpacking warning 3 Safety instructions 3 Intended Use 4 Technical data 4 Device description 5 Commissioning 6 WIFI connection 8 Filter replacement 11 Maintenance 12 ...

Page 3: ...rom its power outlet Check the voltage of 220 240V before use Check the main plug before plugging in When not in use unplug the device from the wall outlet Never run the air purifier unless it is fully assembled Do not insert any objects into the air inlets and outlets of the unit as it may cause a short circuit Special care must be taken when operating the device within the reach of children Do n...

Page 4: ... operating instructions or who have been instructed how to use this device by a responsible person Do not operate the device with wet hands Do not attempt to repair or make any other adjustments both electrical and mechanical to the unit yourself Do not let children play with the packaging such as plastic films Ensure a minimum distance of at least 20cm between the unit and the nearest wall Always...

Page 5: ...5 Device description Figure 1 Figure 2 Display indicators ...

Page 6: ... device automatically adjusts the fan speed from lowest to highest mode depending on the quality of the air 3 Sleep mode In the Sleep mode the device operates at the lowest fan speed for minimal noise disturbance Apart from the Sleep display all other displays turn off 4 Timer available via the App control With the timer you can set the running time of the device Times between 1 and 9 hours can be...

Page 7: ...hine is indicating that the HEPA filter needs to be replaced After replacing the filter renew the filter life indicator as explained above Remote control Press the buttons for the respective function When you use the remote control point it towards the air purifier ...

Page 8: ... the Mode button for 5 seconds until you hear the signal The WIFI connecting icon appears blinking on the display of the device 2 Connect the device to your smartphone Download and install the TuyaSmart App on your smartphone You can find it on the App Store or Google Play Store and also via this QR code 3 Follow all the required steps to create your account Make sure your phone is connected to th...

Page 9: ...twork it must be the same network that the smart phone is using Wait for the connection to complete then click done Control your device via the App Option 2 Auto Scan Select the Auto Scan 1 tab Choose the desired device from list of Available Devices Found 2 then click next 3 to proceed with the connection Fill in the ID and password of the available wireless network it must be the same network th...

Page 10: ...10 4 Configure and control your device remotely You can edit the name of the device within the App From the Dashboard you can control your device remotely ...

Page 11: ...antling the components for filter replacing 2 Remove the protective front and back grid 3 Take out the pre filter and composite filter HEPA filter and carbon filter on both sides 4 Remove the protective foils of the new composite filters HEPA filter and carbon filter 5 Insert the new composite filters first and on both sides and then place back the pre filters on both sides Mount back the protecti...

Page 12: ... cord heats up or appears to be damaged turn off the device and immediately contact our AIR8 specialists 3 months Fan and motor The fan must rotate smoothly and without generating unusual noise If unusual noise is heard check if there is an external element in the ventilator If the motor generates unusual noise please contact our AIR8 specialists 12 months Pre filter Make sure the surface is not d...

Page 13: ...13 air8 tech ...

Page 14: ...14 ...