© Copyright AirBench Ltd 2016
Page 16 of 19
THOROUGH EXAMINATION AND TESTING
If AirBench is used as an LEV system it must be tested at regular (normally 12 month) intervals and certificated
under the COSHH regulations. This service is available from us, or our approved testers.
Thorough examination and test should include:
-
Ensuring the prescribed maintenance routines are being completed and recorded within the system logbook.
-
Condition check of fan, filters, electrics.
-
Performance testing according to recommended face velocities.
-
Visual check that operators are working within effective area.
-
Visual check of effectiveness using, for example, smoke tubes.
Recommended face velocities are as follows:
Fume control: Minimum 0.5m/s
Light dust control: Minimum 1.0 m/s
Heavy dust control: 1.2
–
1.5m/s
Completion of Thorough Examination and Testing should be recorded within the system logbook.