User Guide

Intended Use/Indications

The VenaFlow Elite System is intended as a prophylaxis for deep 

vein thrombosis (DVT). The VenaFlow Elite System is designed 

to be used only with Aircast VenaFlow Elite Compression Cuffs. 

Battery operation use only with DJO battery packs.

Contraindications

The VenaFlow Elite System should not be used by persons with 

known or suspected deep vein thrombosis, severe congestive 

heart failure, pulmonary edema, thrombophlebitis, severe 

arteriosclerosis, or active infection. Do not use on extremities 

which are not sensitive to pain, where cuff will interfere with 

gangrene, on patients with vein ligation or recent skin grafts, 

or extreme deformity of the leg. Do not use the VenaFlow 

Elite System where increased venous or lymphatic return is 

undesirable.

Indications/Contraindications

Warranty

For consigned systems: DJO will repair or replace all or part of the 

30B/30BI or 30B-B/30BI-B system for material or workmanship 

defects for the life of the customer contract.

For purchased systems: DJO will repair or replace all or part of the 

30B/30BI or 30B-B/30BI-B system for material or workmanship 

defects for 3 years from the date of sale.

For disposable cuff purchases: DJO will repair or replace all or 

part of the cuffs, tube units and battery packs for material or 

workmanship defects, not including normal depreciation of 

battery life or charge capacity, for a period of 6 months from the 

date of sale.

Warning and Precautions

• The VenaFlow Elite cuffs are designed for single patient use only.

• Risk of explosion if used in the presence of flammable 

  anaesthetics.

• The equipment or system should not be used adjacent to or 

  stacked with other equipment and, if adjacent or stacked use is 

  necessary, the equipment or system should be observed to 

  verify normal operation in the configuration in which it will be 

  used.

• Medical Electrical Equipment needs special precautions 

  regarding EMC. Portable and Mobile RF Communications 

  Equipment can be affected by other Medical Electrical Devices.

• Cuffs used in combination with warming devices may cause 

  skin irritation. Regularly check for patient comfort, compliance 

  and skin irritation.

• Special attention should be given to those patients with 

  neuropathies or tissue viability problems (i.e. diabetes, arterial 

  or venous insufficiencies).

• To prevent extremity compartment syndrome, special attention  

  should be given to patients who are positioned in the supine 

  lithotomy position for extended lengths of time. This includes 

  patients with or without compression cuffs.

• If you experience pain, swelling, sensation changes or any 

  unusual reactions while using this device, consult your medical 

  professional immediately.

Latex Information

All components of the VenaFlow Elite System are latex-free. All 

VenaFlow Elite cuffs are latex-free and may be placed directly 

against the skin or over a light compression dressing.

Cleaning Instructions

The tube assembly is reusable. Both the device case and the tube 

assembly can be cleaned with mild soap solution, antiseptic or 

disinfectant wipes. Avoid excessive fluids over the top of the 

system. Do not submerge.