R410A 17.5 SEER Inverter Split System Technical Manual
2.
Specification
Model
AIDH2400VG1-D
AIDH3600VG1-D
AIDH4800VG1-D
AIDH6000VG1-D
Power supply
V/Ph/Hz
208-230V/1PH/60Hz
Cooling
Capacity
Btu/h
24000
34500
47000
56000
Minimum Circuit
Ampacity
A
17.7
24.2
31.9
36.5
Max. Overcurrent
Protection
A
30
40
50
60
SEER
17.5
17.5
17.5
17.5
Heating
Capacity
Btu/h
24000
34500
46500
55000
HSPF
9.5
9.0
9.5
9.5
Indoor coil
Number of rows
4×2
4×2
4×2
5×2
Tube outside dia. /
Type
in
0.28 inch / Inner groove tube
Fin spacing /
Thickness / Type
in. / in.
0.062 / 0.0037 / Hydrophilic aluminum
Tube pitch(a) ×
row pitch(b)
in
0.53 × 0.83
0.53 x 0.83
0.53 x 0.83
0.53 x 0.83
Indoor motor
Type
ECM
Rated HP
1/3
1/2
3/4
3/4
Rated RPM
r/min
770
870
1050
1120
FLA
2.8
4.1
6.0
6.0
Indoor fan
Material
Galvanized plate
Type
Centrifugal
Diameter
inch
11
11
11
11
Height
inch
10-5/8
10-5/8
10-5/8
10-5/8
Indoor air flow
CFM
830
1100
1500
1750
ESP
Pa
25
37.5
50
50
Indoor noise level
dB(A)
63
66
67
68
Metering
device
Throttle type
TXV
Model number
3TR
3TR
5TR
5TR
Electrical
Data
Voltage-Phase-Hz
V-Ph-Hz
208/230V 1Ph 60Hz
Minimum Circuit
Ampacity
3.5
5.1
7.5
7.5
Max. Overcurrent
Protection
15
15
15
15
Min / Max Volts
V
187 / 253
187 / 253
187 / 253
187 / 253
Dimension Unit
(H×W×D)
in.
45-3/4 × 19-2/3 × 22
53 × 22 × 24-1/2
Packing (H×W× D)
in.
47-3/5×22-7/8×25-3/5
54-3/4×25-1/8×28
Net / Gross weight
lbs.
126 / 139
126 / 139
170 / 188
170 / 188
Refrigerant piping Liquid side /
Gas side
in.
3/8 / 3/4
3/8 / 3/4
3/8 / 7/8
3/8 / 7/8
Notes:
1. Nominal cooling capacities are based on the following conditions:
Indoor temp: 80°FDB, 66°FWB; Outdoor temp: 95°FDB; Equivalent ref. piping: 5m (horizontal)
2. Nominal heating capacities are based on the following conditions:
Indoor temp: 68°FDB; Outdoor temp: 44°FDB, 43°FWB; Equivalent ref. piping: 5m (horizontal)
3. Actual noise level may differ, depending on the room structure, etc., since these noise values are from an
anechoic room.
Summary of Contents for ACTH2418VG1-D
Page 1: ...R410A Inverter Split System 17 5 SEER Technical Manual January 2021 Version A TM 18SS 01...
Page 4: ...R410A 17 5 SEER Inverter Split System Technical Manual 1 Nomenclature 1 1 Indoor unit...
Page 5: ...R410A 17 5 SEER Inverter Split System Technical Manual 1 2 Outdoor unit...
Page 22: ...R410A 17 5 SEER Inverter Split System Technical Manual 4 Service Space...