Page 38
FIGURE 58
INTEGRATED CONTROL
(Automatic Hot Surface Ignition System)
BLOWER OFF
DELAY JUMPER
TERMINAL DESIGNATIONS
HUM
LINE
XFMR
EAC
COOL
HEAT
PARK
CONT
NEUTRALS
Humidifier (120VAC)
Input (120VAC)
Transformer (120VAC)
Indoor Air Qality Accessory Air Cleaner (120VAC)
Blower − Cooling Speed (120VAC)
Blower − Heating Speed (120VAC)
Dead terminals to park alternate spd taps
Continuous blower
Neutral terminals (120VAC)
PUSH BUTTON
LED
Unit Start Up
WARNING
Do not use this furnace if any part has been under-
water. A flood−damaged furnace is extremely dan-
gerous. Attempts to use the furnace can result in
fire or explosion. Immediately call a qualified ser-
vice technician to inspect the furnace and to replace
all gas controls, control system parts, and electrical
parts that have been wet or to replace the furnace,
if deemed necessary.
WARNING
Danger of explosion. Can cause injury
or product or property damage. Should
the gas supply fail to shut off or if
overheating occurs, shut off the gas
valve to the furnace before shutting off
the electrical supply.
CAUTION
Before attempting to perform any service or mainte-
nance, turn the electrical power to unit OFF at dis-
connect switch.
BEFORE LIGHTING
the unit, smell all around the fur-
nace area for gas. Be sure to smell next to the floor be-
cause some gas is heavier than air and will settle on the
floor.
The gas valve on the 92AF1UH/95AF1UH is equipped
with a gas control switch (lever). Use only your hand to
move switch. Never use tools. If the the switch will not
move by hand, do not try to repair it. Force or attempted
repair may result in a fire or explosion.
Placing the furnace into operation:
92AF1UH/95AF1UH units are equipped with an auto-
matic hot surface ignition system. Do not attempt to
manually light burners on this furnace. Each time the
thermostat calls for heat, the burners will automatically
light. The ignitor does not get hot when there is no call for
heat on these units.