Integrated Control Diagnostic Codes
DIAGNOSTIC CODES
LED Status
DESCRIPTION
LED Off
No power to control or control harware
fault detected.
LED On
Normal operation.
1 Flash
Flame present with gas vavle
de−energized.
2 Flashes
Pressure switch closed with combustion
air inducer de−energized.
3 Flashes
Pressure switch open with combus-
tion air inducer energized.
4 Flashes
Primary limit switch open.
5 Flashes
Rollout switch open.
6 Flashes
Pressure switch cycle lockout.
7 Flashes
Lockout, burners fail to light.
8 Flashes
Lockout, buners lost flame too many
times.
9 Flashes
Line voltage polarity incorrect.
Note − This control is equipped with a push button for diag-
nostic code recall. Press and release the button to recall
stored codes. To clear codes, press and hold the button for
longer than 5 seconds.
Repair Parts List
The following repair parts are available through your local
dealer.. When ordering, include the complete furnace mod-
el number listed on the CSA nameplate −− Example:
92AF1UH045P08B.
All service must be performed by a
licensed professional installer (or equivalent), service
agency, or gas supplier.
Cabinet Parts
Upper access panel
Blower access panel
Top Cap
Control Panel Parts
Transformer
Integrated control board
Door interlock switch
Blower Parts
Blower wheel
Motor
Motor mounting frame
Motor capacitor
Blower housing cutoff plate
Heating Parts
Flame Sensor
Heat exchanger assembly
Gas manifold
Combustion air inducer
Gas valve
Main burner cluster
Main burner orifices
Pressure switch
Ignitor
Primary limit control
Flame rollout switches