background image

80001028 

– Issue 1 10/21 


 

1.2 Warranty Claims 

Any warranty, guarantee or offer provided by Airflow Developments shall not apply if the 
instructions are not observed. The use of accessories, add-ons or other interactions which 
are not recommended or offered by Airflow developments is not permitted. Any damage or 
issues that may occur from misuse, unauthorized tampering or modification with the unit is 
not liable for warranty

. “Unit” shall refer to all items in the scope of this delivery. Upon 

successful delivery the unit is considered correct. If modification, tampering or adjustment 
has been done without the express instruction of Airflow Developments staff or authorized 
technicians, your warranty and guarantee is considered breached if issues arise from this.  
 

1.3 Regulation Guidelines 

If the product is installed correctly and used to its intended purpose, it conforms to all 
applicable regulations and directives at its date of manufacture as per its declaration of 
conformity document. Upon delivery it is recommended that a manager or user check the 
unit for breaches of relevant safety legislation that occurred in transit and then raise any 
issues with the transport company if issues are found.  
 

1.4 Intended Use 

Purigo M 650 and M 850 are designed to be used in a typical residential/commercial 
environment. It is for indoor use only and works with 230V AC supply from a normal utility 
socket. It can be used for filtering indoor air by means of recirculating it and removing the 
small particles, dust, pollen, bacteria, and viruses with the help of air filters. Any use other 
than the intended use is prohibited! 
 

Do not use the unit at a relatively humidity higher than 70%. 
Do not use the unit at temperatures below 5°C and above 40°C. 
Do not operate the unit with different utility/mains power then listed on this manual.  

 

1.5 Receipt 

The delivery contains the air purifier unit. The scope of delivery also includes the items 
below as the assembly kit: 

 

 

Power supply cable, 1 piece  

 

The materials above are attached to the service panel of the unit with adhesive tape.  

 
Please check delivery immediately on receipt for accuracy and damage. If damaged, please 
notify the carrier immediately. In case of delayed notification, any possible claim may be 
void. 
 

1.6 Storage 

When storing for a prolonged time, the following steps are to be taken to avoid damaging 
influences: Protection by dry, air-dustproof packing (plastic bags with drying agent and 
moisture indicators). The storage place must be waterproof, vibration-free, and free of 
temperature variations (ambient temperature limit min/max 0°C/ +40°C). Damages due to 
improper transportation, storage or commissioning must be verified and are not liable for 
warranty. 
 

Summary of Contents for 90001459

Page 1: ...Installation operation and maintenance manual Part No 90001459 90001460 Purigo M650 M850 Please keep this manual with the product ...

Page 2: ...Filter Disposal 5 2 2 Electrical Connection 5 2 3 Recycling 5 3 0 Technical Information 6 4 0 Installation 8 4 1 Unboxing 8 4 2 Installation Location 8 4 3 Mobility 8 4 4 Electrical Connection 8 5 0 Operation 9 5 1 Operating the Power 9 5 2 Speed Control 9 6 0 Maintenance and Service 10 6 1 Important safety information 10 6 2 Maintenance Schedule 11 6 3 Components 11 6 3 Filters 12 Notes Error Boo...

Page 3: ...small particles dust pollen bacteria and viruses Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footwear serves to protect against heavy falling parts and from slipping on slippery surfaces Danger Always pay close attention to danger and warnings signs To not do so could cause serious personal injury deat...

Page 4: ...esigned to be used in a typical residential commercial environment It is for indoor use only and works with 230V AC supply from a normal utility socket It can be used for filtering indoor air by means of recirculating it and removing the small particles dust pollen bacteria and viruses with the help of air filters Any use other than the intended use is prohibited Do not use the unit at a relativel...

Page 5: ...contractor must ensure that the components are separated according to material type 2 1 Filter Disposal The filters of the unit can be considered toxic and harmful to the environment once they are due for replacement Please dispose of these in the most appropriate manner to the local authority 2 2 Electrical Connection The product does not contain batteries in the event of the failure of the unit ...

Page 6: ... consumption W 170 170 Max power consumption A 1 7 1 7 Voltage V 230 50 60 230 50 60 Filters HEPA H14 H14 Filters EPM ePM10 70 ePM10 70 Table 3 Technical Specification Specification M850 M650 Airflow Volume min m3 h 160 100 Airflow Volume max m3 h 850 650 Max covering area m2 71 54 Sound Power Min dBa 34 35 Sound Power Max dBa 66 69 Acoustic Pressure min dBa 1m 26 27 Acoustic Pressure at Max dBa 1...

Page 7: ...54 97 75 700 768 56 125 80 768 815 57 149 85 815 830 57 160 90 830 844 58 168 95 844 844 58 168 100 844 844 58 168 Table 5 M650 Setting levels M650 Adjustment levels Air Volumes m3 h Noise level at 1m dBa Power W 20 0 90 27 4 25 90 140 32 6 30 140 180 37 8 35 180 200 39 12 40 200 270 43 17 45 270 310 46 24 50 310 350 48 32 55 350 400 51 44 60 400 460 53 59 65 460 490 55 74 70 490 535 57 93 75 535 ...

Page 8: ...nce Do not put the unit in a location which will exceed its maximum temperature tolerances Do not place the unit in areas which are to be kept clear for any reason such as a fire exit Allow easy access for adjustment of the potentiometer Do not place the unit inside a cupboard wardrobe or cabinet Do not rest heavy objects on the unit or use it to hold other objects in place It is recommended to no...

Page 9: ...the speed and the airflow Turn the potentiometer anti clockwise to decrease it The adjustment levels with power draw and airflow rates can be seen in section 3 0 Table 3 and 4 of this document Comfort is intended to be the everyday operating speeds and boost for short periods of increased purification Danger Danger to life due to electric shock An electric shock can result in death or serious inju...

Page 10: ...cts the airways from small particles dust pollen bacteria and viruses Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footwear serves to protect against heavy falling parts and from slipping on slippery surfaces Danger Danger to life due to electric shock An electric shock can result in death or serious in...

Page 11: ...eck for unacceptable levels of dirt odours and damage Replace the filter X Check the filter change indicator next to adjustment knob Replace the filter X Fan Check for pollution shading and corrosion damage Clean or replace the fan X Check for abrasion or unbalance Change the fan X Check internal fan connection cable Repair or replace X Silencer Check for dirt and damage Clean or change X 6 3 Comp...

Page 12: ...ay not perform as intended Device Filter Classes Filter QTY Filter Dimensions Ref No Purigo M650 Epm10 70 1 305x305x100 90001513 HEPA 14 1 305x305x292 90001514 Purigo M850 Epm10 70 1 305x305x100 90001515 HEPA 14 1 305x305x292 90001516 Replacement filters must be ordered from Airflow Developments To replace the filters follow the step by step guidance below 1 Remove the back cover unscrewing it wit...

Page 13: ...ow Developments Limited Aidelle House Lancaster House Cressex Business Park High Wycombe Buckinghamshire HP12 3QP UK Email info airflow com Telephone 44 0 1494 525252 Facsimile 44 0 1494 461073 Copyright 2016 Airflow Developments Ltd ...

Reviews: