background image

80001028 

– Issue 1 10/21 

10 
 

4.0 Installation 

Section 4 contains information about the installation of the product into its intended area of 
operation. It contains information about the installation location, mobility, electrical 
connection, and unboxing. 

4.1 Unboxing 

The product will come in a wooden structure and packaged which can be disposed of and 
recycled. 

Ensure this manual is kept with the unit.

 The unit will not come upright, and it is 

not recommended the product is unboxed this way in case it may fall. Move the box to the 
intended location of install using a suitable means using a forklift, crane, or pallet truck. If for 
any reason, the box is damaged and preventing transport, consult section 1.2, 1.5 and 1.7 of 
this document.  

4.2 Installation Location 

The Purigo T air purifiers must be placed in a vertical position in such a way that the air 
inlets and air outlets of the apparatus are not blocked by obstacles and a clear air 
distribution path is guaranteed. The unit is intended to be stood on its feet. Do not seal the 
unit in place. Do not put the unit in a location which will exceed its maximum temperature 
tolerances. Do not place the unit in areas which are to be kept clear for any reason, such as 
a fire exit. Allow easy access for adjustment of the potentiometer. Do not place the unit 
inside a cupboard, wardrobe, or cabinet. Do not rest heavy objects on the unit or use it to 
hold other objects in place. It is recommended to not place the unit where there is a danger 
of it falling from a great height. Do not place the unit in water or submerge it. Do not concrete 
the unit in place or install into a wall, floor, or ceiling.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Warning: 

Due to load the package must be transported by forklift, pallet 

truck or crane.  Ensure symmetrical load distribution and lift the device 
slowly. Always keep a close monitor on the package and do not stand 
underneath it. Do not attempt to operate this machinery and move the unit 
unless properly licensed.  
 

Warning: 

Risk of personal injury and equipment damage due to falling 

from the forklift! Before transporting the unit, please ensure the forks of the 
forklift truck are long enough to lift more than the entire underside of the 
unit! (See figure 2) refer to table 1. Section 1. 
Risk of personal injury and 
equipment damage due to an unpredictable center of gravity. If the package 
is fitted incorrectly, incorrect weight distribution means they can be 
dropped easily. Falling or overturned packages can cause damage or injury! 
 

Figure 2: Make sure the length of the forks is sufficient to reach the end of the package

 

Summary of Contents for 90001461

Page 1: ...Installation operation and maintenance manual Part No 90001461 90001462 Purigo T1750 T2200 Please keep this manual with the product...

Page 2: ...2 2 Electrical Connection 7 2 3 Recycling 7 3 0 Technical Information 7 4 0 Installation 10 4 1 Unboxing 10 4 2 Installation Location 10 4 3 Mobility 12 4 4 Electrical Connection 12 4 5 Levelling 12...

Page 3: ...from small particles dust pollen bacteria and viruses Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footw...

Page 4: ...pical residential commercial environment It is for indoor use only and works with 230V AC supply from a normal utility socket It can be used for filtering indoor air by means of recirculating it and r...

Page 5: ...ation and box weight information is displayed below Table 1 Packaging Information Model Packed Quantity Box Dimensions LxWxH mm Weight Kg T1750 1 2360x810x780 240 T2200 1 2360x810x925 290 Warning When...

Page 6: ...t the device slowly Always keep a close monitor on the package and do not stand underneath it Do not attempt to operate this machinery and move the unit unless properly licensed Warning Risk of person...

Page 7: ...that came with the unit in a manner that is acceptable to the local authority It can be disposed as you would any other retail plug 2 3 Recycling Metal components of the product may be recycled always...

Page 8: ...m dBa 57 60 Power Max W 494 473 Voltage V 230 230 Amps A 2 5 2 5 Frequency Hz 50 50 Height 2313 2332 Width 717 717 Depth 567 720 Weight Kg 150 180 Protection IP Rating 20 20 Body Construction Standing...

Page 9: ...05 54 217 80 1305 1400 56 261 85 1400 1480 57 310 90 1480 1590 57 376 95 1590 1680 57 439 100 1680 1750 57 494 Table 5 T2200 Setting levels T2200 Adjustment levels Air Volumes m3 h Noise level at 1m d...

Page 10: ...be kept clear for any reason such as a fire exit Allow easy access for adjustment of the potentiometer Do not place the unit inside a cupboard wardrobe or cabinet Do not rest heavy objects on the unit...

Page 11: ...depend on the physical conditions of the installation space but to maintain good air circulation the distances listed below should be considered Table 6 Clearance for free airflow Model A mm B mm T17...

Page 12: ...and cause noise To adjust the unit make sure it is first positioned in the correct place with the minimum clearances observed There are 2 nuts on each adjustable foot One is accessible from outside o...

Page 13: ...the speed and the airflow Turn the potentiometer anti clockwise to decrease it The adjustment levels with power draw and airflow rates can be seen in section 3 0 Table 3 and 4 of this document Comfor...

Page 14: ...Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footwear serves to protect against heavy falling parts and...

Page 15: ...ing Check for corrosion contamination damage or scratches etc Clean and repair X Check for Damage Fix the damage X Air Filters Check for unacceptable levels of dirt odours and damage Replace the filte...

Page 16: ...ges Filters are located as displayed on the unit and accessed through opening the door of the product using the key provided You will need to replace all filters at once Component No Description 0 Sup...

Page 17: ...90001511 HEPA 14 610x610x292 90001512 Replacement filters must be ordered from Airflow Developments To replace the filters follow the step by step guidance below 1 Open the front door using the door...

Page 18: ...lencer is clean and damage free from foreign objects Remove the dirt on each silencer using a vacuum cleaner and or a cleaning product without damaging the fabric covering the rock wool Danger after c...

Page 19: ...w Developments Limited Aidelle House Lancaster House Cressex Business Park High Wycombe Buckinghamshire HP12 3QP UK Email info airflow com Telephone 44 0 1494 525252 Facsimile 44 0 1494 461073 Copyrig...

Reviews: