background image

80001028 

– Issue 1 10/21 


 

1.2 Warranty Claims 

Any warranty, guarantee or offer provided by Airflow Developments shall not apply if the 
instructions are not observed. The use of accessories, add-ons or other interactions which 
are not recommended or offered by Airflow developments is not permitted. Any damage or 
issues that may occur from misuse, unauthorized tampering or modification with the unit is 
not liable for warranty

. “Unit” shall refer to all items in the scope of this delivery. Upon 

successful delivery the unit is considered correct. If modification, tampering or adjustment 
has been done without the express instruction of Airflow Developments staff or authorized 
technicians, your warranty and any mentioned guarantees are considered breached.  
 

1.3 Regulation Guidelines 

If the product is installed correctly and used to its intended purpose, it conforms to all 
applicable regulations and directives at its date of manufacture as per its declaration of 
conformity document. Upon delivery it is recommended that a manager or user check the 
unit for breaches of relevant safety legislation that occurred in transit and then raise any 
issues with the transport company if issues are found.  
 

1.4 Intended Use 

Purigo T1750 and T2200 are designed to be used in a typical residential/commercial 
environment. It is for indoor use only and works with 230V AC supply from a normal utility 
socket. It can be used for filtering indoor air by means of recirculating it and removing the 
small particles, dust, pollen, bacteria, and viruses with the help of air filters. Any use other 
than the intended use is prohibited! 
 

Do not use the unit at a relatively humidity higher than 70%. 
Do not use the unit at temperatures below 5°C and above 40°C. 
Do not operate the unit with different utility/mains power then listed on this manual.  

 

1.5 Receipt 

The delivery contains the air purifier unit. The scope of delivery also includes the items 
below as the assembly kit: 

 

Door key, 1 piece  

 

Power supply cable, 1 piece  

 

Fixing bracket, 2 pieces  

 

The materials above are attached to the service panel of the unit with adhesive tape.  

 
Please check delivery immediately on receipt for accuracy and damage. If damaged, please 
notify the carrier immediately. In case of delayed notification, any possible claim may be 
void. 
 

1.6 Storage 

When storing for a prolonged time, the following steps are to be taken to avoid damaging 
influences: Protection by dry, air-dustproof packing (plastic bags with drying agent and 
moisture indicators). The storage place must be waterproof, vibration-free, and free of 
temperature variations (ambient temperature limit min/max 0°C/ +40°C). Damages due to 
improper transportation, storage or commissioning must be verified and are not liable for 
warranty. 
 

Summary of Contents for 90001461

Page 1: ...Installation operation and maintenance manual Part No 90001461 90001462 Purigo T1750 T2200 Please keep this manual with the product...

Page 2: ...2 2 Electrical Connection 7 2 3 Recycling 7 3 0 Technical Information 7 4 0 Installation 10 4 1 Unboxing 10 4 2 Installation Location 10 4 3 Mobility 12 4 4 Electrical Connection 12 4 5 Levelling 12...

Page 3: ...from small particles dust pollen bacteria and viruses Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footw...

Page 4: ...pical residential commercial environment It is for indoor use only and works with 230V AC supply from a normal utility socket It can be used for filtering indoor air by means of recirculating it and r...

Page 5: ...ation and box weight information is displayed below Table 1 Packaging Information Model Packed Quantity Box Dimensions LxWxH mm Weight Kg T1750 1 2360x810x780 240 T2200 1 2360x810x925 290 Warning When...

Page 6: ...t the device slowly Always keep a close monitor on the package and do not stand underneath it Do not attempt to operate this machinery and move the unit unless properly licensed Warning Risk of person...

Page 7: ...that came with the unit in a manner that is acceptable to the local authority It can be disposed as you would any other retail plug 2 3 Recycling Metal components of the product may be recycled always...

Page 8: ...m dBa 57 60 Power Max W 494 473 Voltage V 230 230 Amps A 2 5 2 5 Frequency Hz 50 50 Height 2313 2332 Width 717 717 Depth 567 720 Weight Kg 150 180 Protection IP Rating 20 20 Body Construction Standing...

Page 9: ...05 54 217 80 1305 1400 56 261 85 1400 1480 57 310 90 1480 1590 57 376 95 1590 1680 57 439 100 1680 1750 57 494 Table 5 T2200 Setting levels T2200 Adjustment levels Air Volumes m3 h Noise level at 1m d...

Page 10: ...be kept clear for any reason such as a fire exit Allow easy access for adjustment of the potentiometer Do not place the unit inside a cupboard wardrobe or cabinet Do not rest heavy objects on the unit...

Page 11: ...depend on the physical conditions of the installation space but to maintain good air circulation the distances listed below should be considered Table 6 Clearance for free airflow Model A mm B mm T17...

Page 12: ...and cause noise To adjust the unit make sure it is first positioned in the correct place with the minimum clearances observed There are 2 nuts on each adjustable foot One is accessible from outside o...

Page 13: ...the speed and the airflow Turn the potentiometer anti clockwise to decrease it The adjustment levels with power draw and airflow rates can be seen in section 3 0 Table 3 and 4 of this document Comfor...

Page 14: ...Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footwear serves to protect against heavy falling parts and...

Page 15: ...ing Check for corrosion contamination damage or scratches etc Clean and repair X Check for Damage Fix the damage X Air Filters Check for unacceptable levels of dirt odours and damage Replace the filte...

Page 16: ...ges Filters are located as displayed on the unit and accessed through opening the door of the product using the key provided You will need to replace all filters at once Component No Description 0 Sup...

Page 17: ...90001511 HEPA 14 610x610x292 90001512 Replacement filters must be ordered from Airflow Developments To replace the filters follow the step by step guidance below 1 Open the front door using the door...

Page 18: ...lencer is clean and damage free from foreign objects Remove the dirt on each silencer using a vacuum cleaner and or a cleaning product without damaging the fabric covering the rock wool Danger after c...

Page 19: ...w Developments Limited Aidelle House Lancaster House Cressex Business Park High Wycombe Buckinghamshire HP12 3QP UK Email info airflow com Telephone 44 0 1494 525252 Facsimile 44 0 1494 461073 Copyrig...