background image

80001028 

– Issue 1 10/21 


 

2.0 Disposal 

In section 2.0 information about the safe and responsible disposal of the unit is included.  
Dispose of all components and filters in an environmentally friendly manner in accordance 
with the local codes, practices, and guidelines. An authorized specialist waste processing 
company must dispose of the unit or the individual components. The appointed contractor 
must ensure that the components are separated according to material type. 
 

2.1 Filter Disposal  

The filters of the unit can be considered toxic and harmful to the environment once they are 
due for replacement. Please dispose of these in the most appropriate manner to the local 
authority.  
 

2.2 Electrical Connection 

The product does not contain batteries, in the event of the failure of the unit try a different 
plug and dispose of the one that came with the unit in a manner that is acceptable to the 
local authority. It can be disposed as you would any other retail plug.  
 

2.3 Recycling 

Metal components of the product may be recycled, always check with your local disposal 
outlet which parts can or can’t be recycled in your area. Airflow Developments recommends 
reusing and recycling wherever it is possible to reduce environmental impact. Do not reuse 
dirty filters.  

3.0 Technical Information 

Section 3 contains the technical parameters of the unit. Table 3 and 4 detail the values of 
each setting when adjusted at the potentiometer.  
 

Table 2: General Specification 

Specification 

T1750 

T2200 

Airflow Volume(m3/h) 

300-1750 

370-2200 

Control 

Stepless 

Stepless 

Product Dimensions(mm)(LxWxD) 

2313x717x567 

2313x717x720 

Product Weight(Kg) 

150 

180 

Packaged Dimensions(mm)(LxWxD) 

2360x810x780 

2360x810x780 

Packaged Weight(Kg) 

240 

240 

Max power consumption(W) 

494 

473 

Max power consumption(A) 

2.5 

2.5 

Voltage(V) 

230 

230 

Filters(HEPA) 

HEPA14 

HEPA14 

Filters (EPM) 

ePM1(80%) 

ePM10(70%) 

ePM1(80%) 

ePM10(70%) 

 
 
 

Summary of Contents for 90001461

Page 1: ...Installation operation and maintenance manual Part No 90001461 90001462 Purigo T1750 T2200 Please keep this manual with the product...

Page 2: ...2 2 Electrical Connection 7 2 3 Recycling 7 3 0 Technical Information 7 4 0 Installation 10 4 1 Unboxing 10 4 2 Installation Location 10 4 3 Mobility 12 4 4 Electrical Connection 12 4 5 Levelling 12...

Page 3: ...from small particles dust pollen bacteria and viruses Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footw...

Page 4: ...pical residential commercial environment It is for indoor use only and works with 230V AC supply from a normal utility socket It can be used for filtering indoor air by means of recirculating it and r...

Page 5: ...ation and box weight information is displayed below Table 1 Packaging Information Model Packed Quantity Box Dimensions LxWxH mm Weight Kg T1750 1 2360x810x780 240 T2200 1 2360x810x925 290 Warning When...

Page 6: ...t the device slowly Always keep a close monitor on the package and do not stand underneath it Do not attempt to operate this machinery and move the unit unless properly licensed Warning Risk of person...

Page 7: ...that came with the unit in a manner that is acceptable to the local authority It can be disposed as you would any other retail plug 2 3 Recycling Metal components of the product may be recycled always...

Page 8: ...m dBa 57 60 Power Max W 494 473 Voltage V 230 230 Amps A 2 5 2 5 Frequency Hz 50 50 Height 2313 2332 Width 717 717 Depth 567 720 Weight Kg 150 180 Protection IP Rating 20 20 Body Construction Standing...

Page 9: ...05 54 217 80 1305 1400 56 261 85 1400 1480 57 310 90 1480 1590 57 376 95 1590 1680 57 439 100 1680 1750 57 494 Table 5 T2200 Setting levels T2200 Adjustment levels Air Volumes m3 h Noise level at 1m d...

Page 10: ...be kept clear for any reason such as a fire exit Allow easy access for adjustment of the potentiometer Do not place the unit inside a cupboard wardrobe or cabinet Do not rest heavy objects on the unit...

Page 11: ...depend on the physical conditions of the installation space but to maintain good air circulation the distances listed below should be considered Table 6 Clearance for free airflow Model A mm B mm T17...

Page 12: ...and cause noise To adjust the unit make sure it is first positioned in the correct place with the minimum clearances observed There are 2 nuts on each adjustable foot One is accessible from outside o...

Page 13: ...the speed and the airflow Turn the potentiometer anti clockwise to decrease it The adjustment levels with power draw and airflow rates can be seen in section 3 0 Table 3 and 4 of this document Comfor...

Page 14: ...Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footwear serves to protect against heavy falling parts and...

Page 15: ...ing Check for corrosion contamination damage or scratches etc Clean and repair X Check for Damage Fix the damage X Air Filters Check for unacceptable levels of dirt odours and damage Replace the filte...

Page 16: ...ges Filters are located as displayed on the unit and accessed through opening the door of the product using the key provided You will need to replace all filters at once Component No Description 0 Sup...

Page 17: ...90001511 HEPA 14 610x610x292 90001512 Replacement filters must be ordered from Airflow Developments To replace the filters follow the step by step guidance below 1 Open the front door using the door...

Page 18: ...lencer is clean and damage free from foreign objects Remove the dirt on each silencer using a vacuum cleaner and or a cleaning product without damaging the fabric covering the rock wool Danger after c...

Page 19: ...w Developments Limited Aidelle House Lancaster House Cressex Business Park High Wycombe Buckinghamshire HP12 3QP UK Email info airflow com Telephone 44 0 1494 525252 Facsimile 44 0 1494 461073 Copyrig...

Reviews: