MOUNTING ON THE WALL
NOTE
Avoid mounting the unit on a hollow, echoing partition wall or on
a bedroom wall, or prevent the conduction of sound .
Note that during mounting the unit rises 10 mm higher than the
final height.
Mount the ventilation unit on the wall with a mounting plate, as shown
in the adjacent figure. Make sure that the unit is horizontally level after
mounting .
Adroit DV51CH must be mounted so that the clearance between the
bottom of the cooker hood and the cooker top is at least 426 mm
in case of an electric stove and 650 mm in case a gas stove . The
clearance is 134 mm (i .e . the height of the cooker hood) more between
the bottom of the ventilation unit and the cooker top .
EXTERNAL ELECTRICAL CONNECTIONS
External electrical connections are led to the ventilation unit through
the ceiling bushing for electric connections . The length of the wires
must enable pulling the fan chamber assembly out of the unit without
having to disconnect any of the connections .
NOTE
A space of at least 330
mm must be reserved
in front of the unit for
maintenance purposes .
1
2
REMOVAL OF CONDENSING WATER
Adroit DV51
The Silent Klick siphon is installed in the bottom pool of Adroit
DV51 . The condensing water tube is led from the siphon e .g . to the
siphon of the sink or to the floor drain. Alternatively, an elbow can be
installed in the bottom pool, in which case the Silent Klick siphon
is installed in the condensing water tube to enable maintenance
measures .
NOTE
The Adroit Silent Klick
siphon package is
delivered with Adroit
DV51CH and DV51 .
Installation instructions
for the siphon are
enclosed with the
packaging, and can
also be found online at
www.airflow.com. When
the alternative siphon
installation method is
used, the ring seal and
the locking part must
be moved to the pipe
connection part that is
mounted on the wall .