11
© Airflow - We reserve the right to make changes without prior notice
DV51 DV51CH
INST
ALLA
TION
R
L
90
90
1
Observe in the figure:
1 . Elbow .
2 . Exit hole for the condensing water
outlet .
Adroit DV51CH
In Adroit DV51CH, an elbow is mounted on the bottom pool
between the unit and the cooker hood . Condensing water tube
is led from the elbow e.g. into the siphon of the sink or the floor
drain . The siphon must not be installed inside the cooker hood .
Instead, it must be installed in the condensing water tube so as
to enable maintenance measures . There are approx . 2 mm wide
holes at the rear of the bottom of the Adroit DV51CH ventilation
unit marking the position where the condensing water tube must
be installed .
1 . Install the elbow at the bottom of the ventilation unit without
the siphon (Figure 1) . Install the siphon in the condensing
water tube before the drain or odour trap (Figure 2) . The
Silent Klick siphon helps prevent noise disturbance caused
by the removal of condensing water .
2 . The condensing water tube must be installed either directly
backwards from the cooker hood through the wall, if there
is a sewer connection behind the wall (see figure 2 for the
dimensions of the tube location), or to the odour trap of the
sink (Figure 2) .
3 . 3 . The condensing water pipe must be placed at an
angle so that it always points downwards, enabling the
condensation to drain away from the unit .
2
2
1
1
2