INTRODUCTION

IMPORTANT

Apartment-specific 

ventilation units allows 

residents to adjust the 

ventilation efficiency. 

Ventilation is controlled 

based on the need e .g . 

through the cooker 

hood, ventilation control 

panel, or a separate 

control centre . In order 

to ensure that the 

indoor air presents no 

harm to health and 

remains optimal also 

for the structures of the 

building, 

ventilation 

must be kept on 

without disruptions. 

It is recommended that 

ventilation be left turned 

on during long holidays 

also . This keeps the 

indoor air fresh and 

prevents humidity 

from condensing in 

the ventilation ducts 

and structures . It also 

reduces the risk of 

moisture damage . 

VENTILATION UNIT CONTROL 

Ventilation unit control options.

Ventilation has to be constant for the indoor air to stay healthy 

for the dwellers and the structures of the dwelling . Even for 

longer holidays, it is not advisable to stop the ventilation, 

because the indoor air will become stuffy and, during the 

heating season, the indoor air humidity may condense in the 

ventilation ductwork and structures, causing moisture damage .

 
You can control and automate the ventilation unit operation in 

the following ways: 
- By using an Adroit control panel installed in the building 
-  Through the Adroit Home local network connection and the 

Web interface 

- Through the Adroit Cloud Service and the Web interface 
-  Through a remote monitoring service or building automation 

by using voltage signals or Modbus messages 

-  By using the front panel of the cooker hood; this control option 

applies only to the DV51CH . 

At home

Use this mode when the dwelling is occupied .

Away

Use this ventilation mode when the apartment is 

unoccupied, e .g . during a trip or other long absence .

Boost

Fireplace mode

Use this mode when starting a fire in the fireplace. 

The mode is primarily used to create a short period 

of overpressure in the dwelling, stopping spillage of 

smoke back into the property .

Use this mode to increase the ventilation rate, 

e .g . when there are more people than usual in 

the dwelling and for rapid  clearance of air-born 

contaminants .

Changing the ventilation mode

Adroit DV51

The Adroit DV51 ventilation unit is controlled by using the Adroit 

Control panel . Press the left button of the control panel (See 

icons below) repeatedly until the desired status is shown as the 

middle option on the display .

Adroit Control panel

Summary of Contents for Adroit DV51

Page 1: ...Instruction Manual INSTRUCTION MANUAL DV51 DV51CH...

Page 2: ...on 13 Adjustment 13 Adroit DV51 DV51CH 15 Dimensions and duct outlets 15 MAINTENANCE 16 Adroit DV51 DV51CH 16 Before beginning maintenance work 16 Changing the filters 16 Cleaning the heat recovery ce...

Page 3: ...the right In the left handed version outdoor air blows into the unit from the left side The location of the filters bypass damper and brine heat exchanger not supplied as standard is also mirrored in...

Page 4: ...Service section 4 Registration Page is now opened 5 Enter the following information a Device name enter the desired name for the device b User name c E mail address d Password 6 Press the create acco...

Page 5: ...work and structures causing moisture damage You can control and automate the ventilation unit operation in the following ways By using an Adroit control panel installed in the building Through the Adr...

Page 6: ...ntilation A sufficient supply air flow must be ensured in the room if the cooker hood is to be used simultaneously with non electronic devices Adroit DV51CH The Adroit DV51CH ventilation unit is contr...

Page 7: ...3 Adjust the brightness of the light by pressing the light button until the brightness is adequate 4 To save the setting press the selection button for roughly 3 seconds until the setting mode light...

Page 8: ...L model the parts are mirrored MAIN PARTS Adroit DV51 Post heating resistor 8 Control panel 9 Internal humidity sensor 10 Internal carbon dioxide sensor 10 Humidity sensor optional 11 Carbon dioxide s...

Page 9: ...al 9 R model in the figure In the L model the parts are mirrored MAIN PARTS Adroit DV51CH Internal humidity sensor 10 Internal carbon dioxide sensor 10 Humidity sensor optional 11 Carbon dioxide senso...

Page 10: ...ctric connections The length of the wires must enable pulling the fan chamber assembly out of the unit without having to disconnect any of the connections NOTE A space of at least 330 mm must be reser...

Page 11: ...m of the Adroit DV51CH ventilation unit marking the position where the condensing water tube must be installed 1 Install the elbow at the bottom of the ventilation unit without the siphon Figure 1 Ins...

Page 12: ...lation unit Push in place Figure 2 3 Ensure that the feedthrough seal of the condensing water tube sits firmly around the tube 4 Lift the front of the cooker hood to fit the mountings into the penetra...

Page 13: ...d ventilation The volume flow rate of the air inside the cooker hood is measured with the damper closed and where required adjusted based on the static pressure loss and the performance scheme of the...

Page 14: ...ooker hood extract air D Supply air fan E Extract air fan R model in the figures In the L model the order of the ducts is mirrored C B A B A D E D E Adroit DV51CH Adroit DV51 INSTALLATION Damper in th...

Page 15: ...lowing outdoors from the unit 3 Supply air from the unit to the apartment 4 Extract air from the apartment to the unit L model R model INSTALLATION 239 103 81 598 96 155 141 141 143 1 2 3 4 239 103 81...

Page 16: ...ilter replacement interval depends on the ambient particle concentration It is recommended that the filters be replaced every spring and autumn or at the very least once a year To replace the filters...

Page 17: ...dirty clean it by immersing it in warm water to which a small amount of a mild detergent has been added 6 Rinse the cell clean with a water spray Do not use a high pressure cleaner 7 When all the wate...

Page 18: ...ve the bar from the joint of the damper Turn the crank of the damper motor so that the bar comes off from the bypass damper and turn the damper into the cell bypass position 8 Pull out the upper suppo...

Page 19: ...the grease filter 1 Pull the locking device of the grease filter towards the front edge of the cooker hood while pulling the grease filter downwards until it comes off 2 Clean the grease filter eithe...

Page 20: ...FP 70 A 84 0 94 kW 25 l sect Dimensions w x h x d 598x668x349 mm Weight 60 kg TECHNICAL SPECIFICATIONS ADROIT DV51CH Product title Adroit DV51CH R Adroit DV51CH L Adroit white hood Adroit stainless st...

Page 21: ...7 30 33 39 42 44 47 50 51 52 51 500 39 46 52 54 57 59 62 65 66 67 30 38 40 42 46 49 50 54 56 55 1000 32 40 45 48 52 56 59 64 64 64 20 27 31 34 37 39 42 45 46 46 2000 21 30 37 42 45 48 51 53 53 53 13 1...

Page 22: ...CAL CONNECTION Adroit 51 Adroit DV51CH 1 4 5 2 3 6 1 2 3 4 5 90 C 130 C T2 T1 230V 50Hz GN C B YE WT BN YEGN BU BN BU BN BU BU BU BN BN 2 3 1 R1 YE GN YEGN BN BU WH A Motherboard B 1 Extract air fan t...

Page 23: ...TION OPEN ACTIVATED CLOSED HOUSE AUTOMATION NORMAL SITUATION OPEN ERROR SITUATION HOOD OR VENTILATION UNIT CLOSED ACTIVATED GUARD FUNCTION FLASHING POSITION OF THE DAMPER DAMPER CLOSED CONTACT OPEN DA...

Page 24: ...l mp tila anturin liitin D I1 Digitaalinen tulo 1 D I2 Digitaalinen tulo 2 Ethernet liit nt ja pistotulppa koneen p ll MOTHERBOARD UNDER COVER VALLOX 51 MV VALLOPLUS 180MV Potentiaalivapaa k rkitieto...

Page 25: ...5 0 5 2x2x0 5 0 5 3 x 1 5 MyVallox Control 2x2x0 5 0 5 2x0 5 2x0 5 2x2x0 5 CAT Kytkent rasian max tehonsy tt 6W 2x0 5 MyVallox RH transmitter MyVallox VOC transmitter Adroit RH sensor Adroit Control...

Page 26: ...ignal RS_B Local hardware Modbus B signal 11V1 11 1 V operating voltage AN I Analog input 0 10VDC RM I 24V relay input RM O 24V relay output P Circulation pump V Solenoid valve Ethernet connection on...

Page 27: ...pecified in the temperature setting In winter the Brine heat exchanger will turn on when the outdoor temperature falls below the winter setting Manual In summer the Brine heat exchanger will turn on w...

Page 28: ...luded in the delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example ELV05006 Stig Wahlstr m K Condensing water tube Not included in the delivery IP De...

Page 29: ...00571 5 HR cell 60000566 14 RJ 45 extension cable 60000209 23 Lock nut of the door screw supplied together with the door screw 60000561 6 Lower support for HR cell 60000565 15 Internal humidity and CO...

Page 30: ...LED power source 60000574 6 Lower support for HR cell 60000565 18 Adroit humidity sensor optional 90000612 30 Motherboard 60000575 7 Fan chamber assembly R 60000583 19 Adroit CO2 sensor optional 9000...

Page 31: ...droit Declare that the ventilation unit for supply and extract air equipped with heat recovery and operating as part of a ventilation system has been designed and manufactured to the following specifi...

Page 32: ...it Has been installed and used in accordance with the fitting and wiring instructions supplied with each unit Has not been connected to an unsuitable electrical supply Has not been subjected to misuse...

Reviews: