26
Starting-up and Operating the Wine Guardian
Control Settings
The control has been wired and set up in the factory for testing with
default settings. It is an electronic digital thermostat for one-stage
cooling. No additional adjustments should be necessary except
adjusting the cellar temperature to your preference. If additional
adjustments or changes are necessary, please refer to the
configuration settings section in this manual.
Controller Functions
ON/OFF –
The ON/OFF button will be used to turn the system on or off. When set to the off mode
the control will not allow any of the outputs to energize effectively locking the system out. It will
not allow any outputs to energize until the system is turned on with the ON/OFF button. It should
be noted that high voltage will still be present at the main control board when the system is set to
off even though the control will not allow it to switch to the outputs.
UP Arrow –
The UP arrow will allow the user to increase settings.
DOWN Arrow –
The DOWN arrow will allow the user to decrease settings.
SETTINGS –
The setting button will be used to select between HEAT, COOL and AUTO MODE,
as well as entering the configuration settings. Holding the SETTINGS button for 5 seconds will
enter configuration mode. Once in configuration mode the user can adjust settings by pressing the
UP or DOWN arrows. Pressing the SETTINGS button once will advance to the next configuration
settings. Holding the SETTINGS button for 5 seconds while in configuration mode will store all
changes and exit configuration mode.
For cooling operation only:
Cooling for
60Hz models
is set at 55°F from the factory and 13°C for
50Hz models
. This can be changed by hitting the UP or DOWN arrow, but please refer to
configuration settings # 2 and # 3 for limitations in comparison to the High and Low temperature
alarm settings.
For units with optional humidifier controlled by TTW WG:
The RH% is factory set at 55%.
This can be changed by referring to configurations setting # 6. If no humidifier is attached, the
control will read RH%, but will not be controlling it.
Changing fan operation:
The default setting from the factory is “AUTO” fan. If desired it can be
changed to fan “ON” by accessing configuration setting # 7.