44
Regulating the Cabinet Temperature
To keep the entire cabinet at the same temperature, set the thermostat to run the supply fan
continuously, and not just when there is a call for cooling. Set Fan switch to ON instead of
AUTO, by accessing configuration setting # 7.
Maintenance
WARNING
BEFORE PERFORMING MAINTENANCE ON THE SYSTEM, READ AND UNDERSTAND THE SAFETY
INFORMATION CONTAINED WITHIN THE SAFETY CHAPTER OF THE WINE GUARDIAN MANUAL.
DANGER
HIGH VOLTAGE - RISK OF SERIOUS INJURY OR DEATH
High voltages are present in the cabinets. Turn off all power. Use the Lockout/Tagout
procedure before removing end panels or cover.
CAUTION
SHARP EDGES
RISK OF SEROUS INJURY
SHARP EDGES ARE PRESENT ON THE FAN WHEELS, HOUSEING, INS AND COILS.
Maintenance on Wine Guardian system requires working with high voltage and sheet metal
with possible sharp edges. Only qualified personnel should perform maintenance. Some
tasks require knowledge of mechanical and electrical methods. Make sure you are familiar
with all hazards, general safety related procedures, and safety labels on the system
CAUTION
EXPOSURE TO MICROBIAL GROWTH (MOLD) CAN CAUSE SERIOUS HEALTH PROBLEMS
Standing water in drain pans promote microbial growth (mold) that cause unpleasant odors
and serious health-related indoor air quality problems. If mold is found, remove it
immediately and sanitize that portion of the system.
The Wine Guardian is designed for minimum maintenance. The refrigerant system is
hermetically sealed and requires no maintenance. The fans are permanently lubricated and
require no maintenance. Some maintenance to the system may be required due to dust or dirt in
the air stream.
Summary of Contents for WINE GUARDIAN CAB018
Page 14: ...14 CAB018 Cabinet Unit...
Page 15: ...15 CAB018 and CAB25...