5.  Install the reflector onto the grill by placing the slots on the side of the reflector over the 

lens clips near the center of the grill. While squeezing the middle of the reflector, slide it so 

that the plastic notches rest under the lens clips and the reflector feels secure 

(Figure 13).

6.  Install the grill (with reflector) by squeezing the two ends of the springs together and installing 

them up into the slots on the fan’s housing. Push the grill up into position 

(Figure 14).

7.  Restore power and test your installation.

SECTION 7

Setting the Humidistat

This fan may be equipped with a humidity sensor that automatically turns the fan on when 
humidity is above set point and off when humidity is at or below set point. If the fan is operating 
too long or not enough, first check to see the humidity sensor set point. In cases where the 
ambient humidity level of the room rises higher than the preset level, the fan will turn on even if 
the room is not occupied. This helps prevent conditions that lead to mold growth.

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE SERVICING THE UNIT.

1. 

To set the desired humidity level of the room, remove the grill and locate the 
dehumidistat dial located on the wire compartment cover.

2. 

Set the dial to the relative humidity you want the fan to maintain usually between 50 & 
80%. Moist climates will require higher settings than dry climates. When the humidity 
level of the room is below this setting the fan will remain off. When the humidity level 
rises about this setting the fan will turn on and run until the humidity level falls below 
this setting. 

3.  Reinstall the grill and restore power.

SECTION 8

Use and Care

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

1. 

Cleaning the Grill:

 Remove grill and dislodge reflector from grill by sliding the reflector 

notches from beneath the lens clips on grill. Use a mild detergent, such as dishwashing 
liquid, to clean then dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING 
POWDERS. Completely dry grill before reinstalling. Clean reflector using a dry cloth.  Refer 
to instructions in 

Section 6

 

Completing the Installation

, to reinstall reflector and grill.

2. 

Cleaning the Fan Assembly:

 Wipe all parts with a dry cloth or gently vacuum the fan. 

NEVER IMMERSE ELECTRICAL PARTS IN WATER.

CAUTION:

 ALLOW BULBS TO COOL BEFORE REPLACING.

3. 

Changing the Lamp:

 Disconnect power to the unit. Remove grill by pulling downward 

on grill and squeezing grill springs together to release from housing 

(Figure 13)

. Remove 

Reflector from grill by sliding the reflector notches from beneath the lens clips on grill.  

(Figure 12).

 

Fluorescent Bulb:

 Remove lamp by gently twisting the lamp base counterclockwise while 

applying outward pressure. Installation is the reverse of removal. Replace with Air King 
model 26SBL or a compatible GU24 26 watt self ballasted lamp.

 

LED Bulb:

 Remove lamp by gently twisting the lamp base counterclockwise while applying 

outward pressure. Installation is the reverse of removal. Replace with Air King model 
AK6LED40 or a compatible GU24 6 watt LED lamp.

 

Night Light:

 Unscrew night light bulb from socket and replace with a 4 watt maximum type 

C7 (candelabra base) night light bulb.

CALIFORNIA RESIDENTS ONLY:

WARNING:

 THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR 

CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.

WARNING:

 THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL 

[OR CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE 

REPRODUCTIVE TOXICITY.

Figure 13

Slot

Clip

Figure 13

Summary of Contents for AKF50

Page 1: ...d for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities c When c...

Page 2: ...e rails to the joists Figure 2 www airkinglimited com 210572203 Rev N 1 16 2 of 12 SECTION 4 Ducting NOTE 4 OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES NOTE The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest straightest duct ...

Page 3: ...ntrol Use approved methods for all connections 3c From where you have chosen to access the fan s junction box connect the White wire from the house to the two White wires from the fan Connect the ground wire green or bare copper from the house to the Green wire from the fan Figure 10 Use approved methods for all connections NOTE The fan s receptacle wires might need to be pulled outside compartmen...

Page 4: ...store power SECTION 8 Use and Care CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION 1 Cleaning the Grill Remove grill and dislodge reflector from grill by sliding the reflector notches from beneath the lens clips on grill Use a mild detergent such as dishwashing liquid to clean then dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completel...

Page 5: ... not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SE...

Page 6: ...ire Cover Assembly AKF100 5S1202622 1 Wire Cover Assembly AKF80H 5S1202623 1 Wire Cover Assembly AKF100H 5S1202624 5 1 Blower Assembly AKF50 5S2202029 1 Blower Assembly AKF80LS 5S2202029 1 Blower Assembly AKF100 5S2202401 1 Blower Assembly AKF80H 5S2202401 1 Blower Assembly AKF100H 5S2202401 6 1 Light Assembly 5S1202798 7 1 Outlet Gasket 5S1202043 8 1 Grill Assembly 5S1202620 9 1 26W CFL Lamp 5S99...

Reviews: