background image

www.airkinglimited.com

6727922 Rev. G 1/21

1 of 8

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN 

THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL 

INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should 

always be followed to reduce the risk of fire, electric shock and 

injury to person, including the following:

SAVE THESE INSTRUCTIONS

WARNING:

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC  SHOCK  AND  INJURY  TO  PERSON, 
OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer. If you have 

questions, contact the manufacturer.

b)  Before  servicing  or  cleaning  the  unit,  switch  power  off  at  service 

panel  and  lock  the  service  disconnecting  means  to  prevent  power 
from being switched on accidentally. When the service disconnecting 
means cannot be locked, securely fasten a prominent warning device, 
such as a tag, to the service panel.

WARNING:

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC  SHOCK  AND  INJURY  TO  PERSON, 
OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified person(s) 

in accordance with all applicable codes and standards, including fire-
related construction.

b)  Sufficient air is needed for proper combustion and exhausting of gases 

through the flue (chimney) of fuel burning equipment to prevent back 
drafting.  Follow  the  heating  equipment  manufacturer’s  guideline  and 
safety standards such as those published by the National Fire Protection 
Association (NFPA) and the American Society for Heating, Refrigeration, 
and Air Conditioning Engineers (ASHRAE), and the local code authorities.

c)  When cutting or drilling into wall or ceiling, do not damage electrical wiring 

and other hidden utilities.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. 

DO  NOT  USE  TO  EXHAUST  HAZARDOUS  OR  EXPLOSIVE 
MATERIALS AND VAPORS.

d)  Ducted fans must always be vented to the outdoors.

e)  This unit must be grounded.

f)  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

g)  Read all instructions before installing or using exhaust fan.

WARNING:

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, DO NOT USE THIS FAN WITH 
ANY SOLID-STATE SPEED CONTROL DEVICE.

 

a)  If this unit is to be installed over a tub or shower, it must be marked 

as  appropriate  for  the  application  and  be  connected  to  a  GFCI 
(Ground Fault Circuit Interrupter) – protected branch circuit.

WARNING:

 DO NOT USE IN KITCHENS.

WARNING: 

THE DUCTING FROM THIS FAN TO THE 

OUTSIDE  OF  THE  BUILDING  HAS  A  STRONG  EFFECT 

ON  THE  AIR  FLOW,  NOISE  AND  ENERGY  USE  OF  THE  FAN.  USE 
THE  SHORTEST,  STRAIGHTEST  DUCT  ROUTING  POSSIBLE  FOR 
BEST  PERFORMANCE,  AND  AVOID  INSTALLING  THE  FAN  WITH 
SMALLER  DUCTS  THAN  RECOMMENDED.  INSULATION  AROUND 
THE  DUCTS  CAN  REDUCE  ENERGY  LOSS  AND  INHIBIT  MOLD 
GROWTH.  FANS  INSTALLED  WITH  EXISTING  DUCTS  MAY  NOT 
ACHIEVE THEIR RATED AIRFLOW.

Exhaust Fan

Models:
BFC90, BFC90H, BFC100, BFC100H

Summary of Contents for BFC90

Page 1: ...xhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the...

Page 2: ...housing in the previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 1 SECTION 4 Ducting NOTE 4 OR LARGER RIGID DUCT IS RECOMMENDED FOR BE...

Page 3: ...insulation contact Type IC and it is recommended that this fan be completely covered by insulation in order to reduce heat loss or gain to unconditioned space 2 Plug the fan s quick connect motor cord...

Page 4: ...be accepted CUSTOMER SERVICE Toll Free 800 465 7300 Our Customer Service team is available to assist you with product questions service center locations and replacement parts They can be reached Mond...

Page 5: ...ombustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les normes de s curit telles que celles publi es par la National Fire Protection Association N...

Page 6: ...mit s des rails aux solives Figure 1 SECTION 4 Conduits REMARQUE UN CONDUIT PLUS RIGIDE DE 4 PO OU PLUS EST RECOMMANDE POUR UNE MEILLEURE PERFORMANCE ATTENTION TOUS LES CONDUITS DOIVENT TRE CONFORMES...

Page 7: ...e inconditionn 2 Brancher le cordon raccordement rapide dans le r ceptacle Ce cordon ne s ajuste que d une seule fa on dans le r ceptacle Figure 8 3 Installer la grille en pressant ensemble les deux e...

Page 8: ...pi ces de rechange Vous pouvez la rejoindre du lundi au vendredi de 8h 00 16h 00 HNE Veuillez avoir le num ro du mod le disponible ainsi quele genre et le style qui se trouvent sur l tiquette l int ri...